manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberPower
  6. •
  7. Inverter
  8. •
  9. CyberPower CPS1200EILCD User manual

CyberPower CPS1200EILCD User manual

This manual suits for next models

1

Other CyberPower Inverter manuals

CyberPower CPS600E-DE User manual

CyberPower

CyberPower CPS600E-DE User manual

CyberPower PowerTrip 240 User manual

CyberPower

CyberPower PowerTrip 240 User manual

CyberPower CPS1500PIE User manual

CyberPower

CyberPower CPS1500PIE User manual

CyberPower CPS140BI User manual

CyberPower

CyberPower CPS140BI User manual

CyberPower CPS175SURC1 User manual

CyberPower

CyberPower CPS175SURC1 User manual

CyberPower CPS140CHI User manual

CyberPower

CyberPower CPS140CHI User manual

CyberPower CPSPV36000ETLA-WB User manual

CyberPower

CyberPower CPSPV36000ETLA-WB User manual

CyberPower CPSPV3600ETL-IN SLV User manual

CyberPower

CyberPower CPSPV3600ETL-IN SLV User manual

CyberPower CPS150SI User manual

CyberPower

CyberPower CPS150SI User manual

CyberPower CPS150BURC1 User manual

CyberPower

CyberPower CPS150BURC1 User manual

CyberPower CPS1200EILCD User manual

CyberPower

CyberPower CPS1200EILCD User manual

CyberPower POWERTRIP 480 User manual

CyberPower

CyberPower POWERTRIP 480 User manual

CyberPower CPS150CHURC1 User manual

CyberPower

CyberPower CPS150CHURC1 User manual

CyberPower CPS1000AI User manual

CyberPower

CyberPower CPS1000AI User manual

CyberPower CPSHB300ETR User manual

CyberPower

CyberPower CPSHB300ETR User manual

CyberPower Powertrip 480 User manual

CyberPower

CyberPower Powertrip 480 User manual

CyberPower POWERTRIP 240 User manual

CyberPower

CyberPower POWERTRIP 240 User manual

CyberPower CPS175SU User manual

CyberPower

CyberPower CPS175SU User manual

CyberPower CPSPV30000ETL-WB User manual

CyberPower

CyberPower CPSPV30000ETL-WB User manual

CyberPower CPS1000EI User manual

CyberPower

CyberPower CPS1000EI User manual

CyberPower CPS100PBU User manual

CyberPower

CyberPower CPS100PBU User manual

CyberPower CPSPI3700EVF380 User manual

CyberPower

CyberPower CPSPI3700EVF380 User manual

CyberPower CPSHB300ETR User manual

CyberPower

CyberPower CPSHB300ETR User manual

CyberPower CPSPV5000ETL User manual

CyberPower

CyberPower CPSPV5000ETL User manual

Popular Inverter manuals by other brands

Omnik New Energy Omniksol-1.5k-TL user manual

Omnik New Energy

Omnik New Energy Omniksol-1.5k-TL user manual

Agilent Technologies 33250A user guide

Agilent Technologies

Agilent Technologies 33250A user guide

4-noks ZR-SWITCH-RC instruction manual

4-noks

4-noks ZR-SWITCH-RC instruction manual

V&T V5 Series user manual

V&T

V&T V5 Series user manual

Hon Turing HT-T-S1000-12 introduction

Hon Turing

Hon Turing HT-T-S1000-12 introduction

Metabo E 140 SP Plus Original operating instructions

Metabo

Metabo E 140 SP Plus Original operating instructions

BARRON EXITRONIX Tucson Micro Series installation instructions

BARRON

BARRON EXITRONIX Tucson Micro Series installation instructions

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

Baumer

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

electroil

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

Silicon Solar TPS555-1230 instruction manual

Silicon Solar

Silicon Solar TPS555-1230 instruction manual

Mission Critical Xantrex Freedom SW-RVC owner's guide

Mission Critical

Mission Critical Xantrex Freedom SW-RVC owner's guide

HP 3312A Operating and service manual

HP

HP 3312A Operating and service manual

Hoymiles HM-500T user manual

Hoymiles

Hoymiles HM-500T user manual

Nitecore SPM10 user manual

Nitecore

Nitecore SPM10 user manual

AEG Protect PV installation manual

AEG

AEG Protect PV installation manual

On Board TruePower Plus 1200MS owner's manual

On Board

On Board TruePower Plus 1200MS owner's manual

Plugreen PGM-200P-230 Installation and operation manual

Plugreen

Plugreen PGM-200P-230 Installation and operation manual

Fourgroup Easy use and Programming Handbook

Fourgroup

Fourgroup Easy use and Programming Handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CPS1200EILCD/CPS2200EILCD
User’s Manual K01-C000067-00
IMPORTANT SAFETY INFORMATION
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack,
install, or operate the HOME UPS.
Insure the wall outlet and HOME UPS are located near the equipment being attached for proper
accessibility.
To reduce risk of damage and injury, please use batteries with good quality.
Provide adequate ventilation for the battery compartment. The battery enclosure should be designed to
prevent accumulation and concentration of hydrogen gas at the top of the compartment.
DO NOT expose the HOME UPS to rain, snow or liquids of any type. The HOME UPS is designed for
indoor use only.
DO NOT obstruct the ventilation openings.
DO NOT connect neutral of the power distribution box on the wall to:
(a) The OUTPUT neutral of HOME UPS.
or (b) The INPUT neutral of equipment.
Otherwise the reversed polarity will damage the HOME UPS and the connected equipment.
CAUTION! Risk of electric shock, do not remove cover. No user serviceable parts inside.
The battery can energize hazardous live parts inside even when theAC input power is disconnected.
To avoid electrical shock, turn off the HOME UPS and unplug it from the AC power source before
servicing the battery. Servicing the battery can only be performed by trained personnel.
INSTALLING YOUR HOME UPS SYSTEM
UNPACKING
Inspect the unit upon receipt. The box should contain the following:
HOME UPS Unit¯1; Power Cord¯1; User Manual¯1
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Insure that the equipment plugged into the AC outlet does not exceed the HOME UPS unit’s rated
capacity (1200VA/720W for CPS1200EILCD; 2200VA/1320W for CPS2200EILCD). If rated unit
capacities are exceeded, an overload condition may occur and cause the HOME UPS unit to shut
down or the circuit breaker trip.
2. If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert
Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only
calculates the maximum amount of VA that the equipment can use, not what is typically used by the
equipment at any one time. Users should expect usage requirements to be approximately 60% of
below value.
TO ESTIMATE POWER REQUIREMENTS
1. 220 V x Amps(A)= VA
2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual
requirements. There are many factors that can affect the amount of power that your computer system
will require. The total load that you will be placing on the battery-powered outlets should not exceed
80% of the unit’s capacity.
HARDWARE INSTALLATION GUIDE
Before installation, please read and understand the following instructions:
1. Placement
The HOME UPS must be installed in a protected environment away from heat- emitting appliances
such as a radiator or heat register. Do not install this product where excessive moisture is present.
2. Ventilation
The location should provide adequate air flow around the HOME UPS with 10 CM minimum
clearance on all sides for proper ventilation.
3. Connect the Battery
Connect the external battery with the DC cables
from the back of the HOME UPS. Follow battery
polarity guide located near battery cables as
below.
“+”Red cable for battery positive polarity;
“-”Black cable for battery negative polarity.
4. Connect to AC and Charge the Battery
Connect the HOME UPS to a wall outlet. Avoid using extension cords and adapter plugs. Charging
the battery for at least 8 hours is recommended to insure that the battery is fully charged. To
recharge the battery, simply leave the unit plugged into a wall outlet. To maintain optimal battery
charge, leave the HOME UPS plugged into an AC outlet at all times.
This HOME UPS can be charged even when HOME UPS is not turned on.
5. Connect the Load
Connect the equipment to the HOME UPS outlet. Please make sure that the total loads of your
equipments are less than the maximum total power load of the HOME UPS.
BASIC OPERATION
FRONT PANEL DESCRIPTION
1. LCD Module Display.
High resolution and intelligent LCD display shows all the HOME UPS information with icons and
messages. For more information please check the “Definitions for Illuminated LCD Indicators”
section.
2. Power Switch
Press the power switch to turn the HOME UPS ON or OFF.
3. LCD Function Selected Switch
The switch can be used to select the LCD display contents including input/output voltage and load
percentage, etc.
REAR PANEL DESCRIPTION
1. DC Input Cable (Black)
Connect to battery negative polarity.
2. DC Input Cable (Red)
Connect to battery positive polarity.
3. Input Circuit Breaker
The circuit breaker provides optimal overload protection.
All manuals and user guides at all-guides.com
all-guides.com
4. Charger Control*
A. Select “Default” setting for general application. The charge voltage is 13.7V, 27.4V
respectively for CPS1200EI and CPS2200EI.
B. Select “Customized” setting for special battery condition. The charge voltage is 13.3V, 26.6V,
respectively for CPS1200EI and CPS2200EI.
*Note: Operate by trained professionals ONLY. Incorrect operation will damage the battery.
5. Input Voltage Range Selector
Input voltage range is defined in specification section. Output voltage is the same as input voltage
in AC mode.
A. Select “Narrow” setting for general electrical appliance such as TUBE LIGHT, ENERGY
SAVING LAMP, TV, JUICER & MIXER etc. It is not suitable for high-power motor or inductive
load, such as the fridge of 1KW, the motor of 800W, AIR COOLER(having risk of rebooting)
and so on. In this mode, the HOME UPS operating voltage in AC mode is within 190~ 260Vac
with the same output voltage. The line sensitivity is higher.
B. Select “Wide” setting to save energy. In this mode the operating range of voltage for the
HOME UPS is 100-280Vac. Therefore the output voltage will be the same as the MAINS input
voltage. The HOME UPS unit in this mode has a lower sensitivity with a longer transfer time for
switching from AC mode to battery mode in the event of power failure. You can safely connect
and use home appliances which are not sensitive to transfer time limitations such as florescent
tubes, bulbs, TV etc.
6. AC outlet**
The HOME UPS provides one outlet for connected equipment to insure temporary uninterrupted
operation during a power failure and against surges and spikes.
7. AC Inlet
Connect to utility power through the input power cord.
Functional Test
AC Mode
The HOME UPS delivers power to the load derived from the utility and maintains proper battery charge.
On-Battery Mode
The HOME UPS operates on battery when the utility voltage has fallen outside the limits. Local users
are alerted to this mode of operation by visual and audible indicators. The HOME UPS provides power
to the load from the battery and the output voltage of the HOME UPS are regulated within a narrow
range
1. Switch On
Press the power switch then the status LCD will light up.
2. Switch Off
Press again the power switch, the status LCD will go off.
3. Cold Start / Start on Battery:
This HOME UPS can be turned on even when AC is not present.
Press the power switch then the status LCD will light up.
ROUTINE MAINTENANCE AND STORAGE
ROUTINE MAINTENANCE
1. Use dry soft clothes to clean the panel and plastic parts. Do not use any detergent that contains
alcoholic ingredient.
2. Unplug the HOME UPS from power inlet if the HOME UPS will not operate for long period of time.
STORAGE
1. First turn off your HOME UPS and disconnect its power cord from the wall outlet. Disconnect all
cables connected the HOME UPS to avoid battery drain.
2. The HOME UPS should be stored in a cool dry location.
3. Make sure the battery is fully charged before the HOME UPS is stored.
4. For extended storage in moderate climates, the battery should be charged for 12 hours every 3
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat
it every 2 months in high temperature locations.
TROUBLE SHOOTING
Problem Possible Causes Remedy
No LCD display
1. Battery Weak 1. Re-charge battery
2. Battery defective 2. Battery replacement.
3. Power switch is not
pressed 3. Press and hold power
switch.
Mains normal but not
works in AC mode
1. AC Input missing 1. Check AC input
connection.
2. Input protector is effective 2. Reset the input protector.
Alarm buzzer beeps
continuously Overload Verify that the load
matches the capability
specified in the specs.
Backup time is shortened Overload Remove some non-critical
load.
Battery voltage is too
low. Charge battery for 8 hours
or more.
If any abnormal situations occur that are not listed above, please contact service personnel.
TECHNICAL SPECIFICATIONS
Model CPS1200EILCD CPS2200EILCD
Capacity (VA) 1200VA 2200VA
Capacity (Watts) 720W 1320W
Input
Input Voltage Range Wide mode: 100VAC-280VAC
Narrow mode: 190VAC-260VAC
Frequency Range 50/60Hz
Output
On Battery Output
Voltage Simulated Sine Wave at 220Vac +/-10%
On Battery Output
Frequency 50/60Hz
Overload Protection On Utility: Circuit Breaker, On Battery: Internal Current Limiting
Physical
Total # of HOME UPS
Receptacles (1) Shuko/FR/UK/India/NEMA/UN
Maximum Dimensions 265mm(L)* 250cm(W)* 90cm(H)
Weight 2.05 kg / 4.5 Lbs 2.2 kg / 4.9 Lbs
Battery
Lead Acid Battery 12V 24V
Warning Diagnostics
Indicators HOME UPS Status Display,
Audible Alarms Low Battery, Overload, Fault
Environmental
Operating Temperature +32°F to 104°F ( 0°C to 40°C )
Operating Relative
Humidity 0 to 90% NON-CONDENSING
Management
Auto-Charger Yes
Auto-Restart Yes
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Line mode
Select SW
Press
HOME UPS Status
Display Capacity Display Digital Value Display
Load
Cap. Battery
Cap. Input
Voltage Output
Voltage %
of Load
Initial V X X -- X V V
1st V X X -- V X V
2nd V X X -- X V V
(Overload) V X X V -- -- -- -- --
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Battery mode
Select SW
Press
HOME UPS Status
Display Capacity Display Digital Value Display
Load
Cap. Battery
Cap. Input
Voltage Output
Voltage %
of Load
Initial X V -- -- X V V
1st X V -- -- V X V
2nd X V -- -- X V V
Press >3sec
(Sound Disable) X V V -- -- -- -- -- --
Press >3sec
again
(Sound Enable) X V X -- -- -- -- -- --
(Overload) X V -- V -- -- -- -- --
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Off charging mode (Auto bypass)
Select SW
Press
HOME UPS Status
Display Capacity Display Digital Value Display
Load
Cap. Battery
Cap. Input
Voltage Output
Voltage %
of Load
Initial V X X X X X X X X
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Visit www.cpsww.com for more product information and the nearest CyberPower local contact for your
region.
Entire contents copyright ©2012 CyberPower Systems, Inc All rights reserved. Reproduction
in whole or in part without permission is prohibited.
All manuals and user guides at all-guides.com