manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberPower
  6. •
  7. UPS
  8. •
  9. CyberPower CSN30C12V-E User manual

CyberPower CSN30C12V-E User manual

Other CyberPower UPS manuals

CyberPower Smart App Sinewave Series User manual

CyberPower

CyberPower Smart App Sinewave Series User manual

CyberPower PP800 User manual

CyberPower

CyberPower PP800 User manual

CyberPower CP585LCD User manual

CyberPower

CyberPower CP585LCD User manual

CyberPower OR1500LCDRTXL2U Use and care manual

CyberPower

CyberPower OR1500LCDRTXL2U Use and care manual

CyberPower ST425 User manual

CyberPower

CyberPower ST425 User manual

CyberPower CP600LCD Manual

CyberPower

CyberPower CP600LCD Manual

CyberPower OR1500LCDRTXL2U User manual

CyberPower

CyberPower OR1500LCDRTXL2U User manual

CyberPower LX1100G3-FC User manual

CyberPower

CyberPower LX1100G3-FC User manual

CyberPower OLS6000E User manual

CyberPower

CyberPower OLS6000E User manual

CyberPower PR1500 User manual

CyberPower

CyberPower PR1500 User manual

CyberPower CST1300AL User manual

CyberPower

CyberPower CST1300AL User manual

CyberPower 649532108251 User manual

CyberPower

CyberPower 649532108251 User manual

CyberPower CP350SLG User manual

CyberPower

CyberPower CP350SLG User manual

CyberPower BRG1350AVRLCD User manual

CyberPower

CyberPower BRG1350AVRLCD User manual

CyberPower OL1000RTXL2U User manual

CyberPower

CyberPower OL1000RTXL2U User manual

CyberPower Value1200ELCD User manual

CyberPower

CyberPower Value1200ELCD User manual

CyberPower CPS1500AVR User manual

CyberPower

CyberPower CPS1500AVR User manual

CyberPower CPS625AVR User manual

CyberPower

CyberPower CPS625AVR User manual

CyberPower OR1000ELCDRM1U User manual

CyberPower

CyberPower OR1000ELCDRM1U User manual

CyberPower OR500LCDRM1U User manual

CyberPower

CyberPower OR500LCDRM1U User manual

CyberPower 649532013500 User manual

CyberPower

CyberPower 649532013500 User manual

CyberPower CST625G User manual

CyberPower

CyberPower CST625G User manual

CyberPower OL6000ERT3U User manual

CyberPower

CyberPower OL6000ERT3U User manual

CyberPower UT400EG User manual

CyberPower

CyberPower UT400EG User manual

Popular UPS manuals by other brands

AEG Protect 3.M 2.0 manual

AEG

AEG Protect 3.M 2.0 manual

Alpha Novus FXM 650 Installation and operation manual

Alpha

Alpha Novus FXM 650 Installation and operation manual

Pylontech Victron & Pylontech US5000 manual

Pylontech

Pylontech Victron & Pylontech US5000 manual

BEL LDX-U20 user manual

BEL

BEL LDX-U20 user manual

Mustek PowerMust 530(B) Plus Startup manual

Mustek

Mustek PowerMust 530(B) Plus Startup manual

Emerson Liebert NXL series Operation and maintenance manual

Emerson

Emerson Liebert NXL series Operation and maintenance manual

MAKELSAN BOXER SERIES user manual

MAKELSAN

MAKELSAN BOXER SERIES user manual

Block PC-0524-400-0 manual

Block

Block PC-0524-400-0 manual

Eaton 3S Advanced user's guide

Eaton

Eaton 3S Advanced user's guide

Best Power 610 quick start guide

Best Power

Best Power 610 quick start guide

Best Power Unity/I UT3K user manual

Best Power

Best Power Unity/I UT3K user manual

Mustek PowerMust 400 Offline user manual

Mustek

Mustek PowerMust 400 Offline user manual

Xantrex Trace 512 UR-UPS owner's manual

Xantrex

Xantrex Trace 512 UR-UPS owner's manual

Forza SL-1501UL user manual

Forza

Forza SL-1501UL user manual

LEGRAND keor 310081 quick start guide

LEGRAND

LEGRAND keor 310081 quick start guide

Eaton Powerware 9125 installation guide

Eaton

Eaton Powerware 9125 installation guide

ABB Conceptpower DPA 500 operating manual

ABB

ABB Conceptpower DPA 500 operating manual

ZincFive BC Series installation instructions

ZincFive

ZincFive BC Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

User’s Manual for
CyberShield
CSN30C12V-E
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important instructions regarding the installation and operation of this device.
Read this manual thoroughly before attempting to unpack , install or operate this device
CAUTION!
CAUTION!
INSTALLATION
BATTERY REPLACEMENT
This battery is hot-swappable. As long as utility power is on , you may leave the Battery Backup
Power Supply and connected equipment on while replacing a new battery.
Step 1:
a. Remove the case screw.
b. Open the battery cover.
Step 2:
a. Loosen strap from battery.
b. Slide battery off of the shelf.
c. Remove battery cable connector.
Step 1:
a. Remove the case screw.
b. Open the battery cover.
Step 2:
a. Loosen the battery strap.
b. Disconnect battery cable connector
to remove battery.
c. Replace with new battery and
reconnect the battery connector.
Step 3:
a. Tighten the battery strap.
b. Close the battery cover and
lock the case screw.
CAUTION! Power Cable Selection:
A power cable (4.5m max.) being identified as 18AWG, "OUTDOOR" or "WATERPROOF"
should be selected while necessary.
CAUTION!
The battery can energize hazardous live parts inside even when the AC input power is
disconnected.
To reduce the risk of electric shock, keep the cover on. there are no user serviceable
parts inside the unit, including the battery. Please contact us or our dealer for service.
When replacing batteries, the replacement should have the same rating:
Listed/Certified Valve Regulated Lead Acid Battery, 12V, max. 9Ah.
CAUTION! Before replacing batteries, remove conductive jewelry, such as chains, watches and rings,
and use tools with insulated handles. High energy passed through conductive materials
can cause severe burns.
CAUTION! Don’t dispose of batteries in a fire. Batteries may explode if improperly disposed.
Recycle batteries in accordance with local regulations.
The UPS battery is charging when it’s connected to utility power. The battery is charging
during its first 24 hours of normal operation. Don’t expect full battery capacity during this
initial charging period.
CAUTION!
Step 3:
a. Use the enclosed installation template to mark an installation location for the unit.
b. The unit can only be wall-mounted in one direction with the connector facing down.
d. Tighten the screws to secure the unit.
e. Reconnect the battery cable connector and place the battery back.
CAUTION! Keep the gap around the UPS for air circulation.
CyberShield UPSs are designed to provide a local power solution for
cable telephony, wireless local loop (WLL), and fiber to the home
(FTTH) broadband equipment.
c. Mount the unit on the wall with 3 mounting screws into the keyhole slots.
13/32”
3/16”
Runtimes based on testing fully-charged, new batteries at normal operating conditions.
Runtime curve is approximate and varies based on battery age, level of charge at test,
environment, and other variables.
CAUTION!
OPERATION
Please refer to the following recommendations to connect equipment and power source.
Step3. Plug the UPS power cord into the utility power cord inlet.
Step4. Plug the UPS power cord into the wall outlet.
Step2. Refer to the COMMUNICATION SIGNALS to setup the connector and connect equipment
Step1. Refer to the BATTERY REPLACEMENT to connect the battery.
to the UPS.
To avoid electric shock, unplug power cable from the AC power source before servicing
the battery or installing a computer component.
CAUTION!
COMMUNICATION SIGNALS
The communication signals of this unit are isolated from the internal circuitry via open collector opto-
coupled transistors. The connection “SIG RTN” (Signal Return) is a common return point for all
communication signals. In the typical application, the attached equipment digital ground connects to
Signal Return, and pull-up resistors turn the open collector signals into logic levels.
12V
12V RTN
SIG RTN
ON BATTERY
REPLACE BATTERY
BATTERY MISSING
LOW BATTERY
+Voltage output
- Voltage output
Signal return
Low when operating from utility line.
Open when operating from battery.
Low when battery is charged.
Open when battery fails the Self Test.
Low when battery is present.
Open when battery is missing.
Low when battery is near full charge capacity.
Open when operating from a battery with < 10% capacity.
Utility power cord inlet
Communication signals
MessageSignal
It is recommended to connect the unit to the required equipment and battery before
plugging in the utility power.
CAUTION!
SPECIFICATION
LIMITED WARRANTY
CyberPower warrants to you, the Initial Purchaser, that the Product will be free from defects in material and workmanship for three years from the date of original purchase, subject to the terms of this Limited
Warranty. This Limited Warranty gives you specific rights, and you may have other rights, which vary from State to State or Province to Province.
Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose, if applicable to the Product, is limited in duration to three years. This provision shall NOT create any Implied Warranty or
Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product. NOTE: Some States and Provinces do not allow limitations on how long an implied warranty lasts,
so the above limitation may not apply to you.
To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty. Your sole and exclusive remedies are those provided by this
Limited Warranty. This exclusion of other express warranties applies to written and oral express warranties. CyberPower excludes any liability for personal injury. CyberPower excludes any liability for direct,
indirect, special, incidental, or consequential damages, whether for damage to or loss of property, loss of profits, business interruption, information or data. This exclusion applies even though damage or loss
is caused by negligence or other fault. NOTE: Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES.
CyberPower does not sell the PRODUCT for use in high-risk activities. The PRODUCT is not designed or intended for use in hazardous environments requiring fail-safe performance, including the operation
of nuclear facilities, aircraft navigation or communication systems, air traffic control, weapons systems, life support or medical applications or for use in any circumstance in which the failure of the PRODUCT
could lead directly to death, personal injury, or severe physical or property damage, or that would affect operation or safety of any medical or life support device (collectively, "High Risk Activities").
CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities. CyberPower does not authorize use of any PRODUCT in any High Risk activities.
ANY SUCH USE IS IMPROPER AND IS A MISUSE OF A CYBERPOWER PRODUCT.
The Limited Warranty is governed by the laws of the United States and the State of Minnesota, without reference to conflict of law principles. The application of the United Nations Convention of Contracts for
the International Sale of Goods is expressly excluded
FCC NOTICE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1)Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an
experienced radio/TV technician for help.
CAUTION: Shielded signal cables must be used with this device to ensure compliance with Class B FCC limits.
CAUTION: Any changes or modifications not expressly approved by Cyber Power could void the authority granted by the FCC to operate this equipment.
For more information, please contact:
CyberPower Systems ( USA ), Inc. 4241 12th Avenue East, Suite 400, Shakopee, MN55379 Phone: (952)403-9500 Fax: (952)403-0009 www.cpsww.com
CyberPower Systems ( EUROPE ), Inc. Flight Forum 3545, 5657DW Eindhoven, The Netherlands E-mail: [email protected] eu.cyberpowersystems.com
Input
Voltage Range
Frequency Range
Output
On Battery Output Voltage
Continuous Power Capability
Output Power Max
Efficiency
Battery
Battery Type
Numbers of Battery
Typical Recharge Time
Replaceable
Surge Protection and Filtering
Lightning / Surge Protection
Warning Diagnostics
Indicators
Management
Auto-Charge
Communication Interface
Physical
Maximum Dimensions (L*W*D)
Weight (kg)
Environment
Operating Temperature
Operating Humidity
Max Operating Elevation
Max Storage Elevation
Storage Temperature
100 - 240V
AC
50 - 60 Hz
12VDC
30W
30W
Sealed, Maintenance Free Lead-Acid Battery
7.2Ah / 12V x 1
18Hours to 90% (no load)
Yes
Yes
AC, Output, Battery
Yes
On Battery, Replace Battery, Battery Missing,
Low Battery
27.5cm x 20.4cm x 9.9cm
3.51
0 - 95% noncondensing within enclosure
10,000ft (3,048m)
50,000ft (15,240m)
K01-3012004-01
Deliver spent batteries to a recycling facility or ship to the manufacturer in the replacement battery packing material.
-4°F - 122F(-20℃- 50℃)
-4°F - 122F(-20℃- 50℃)
>80%
COLD START
The cold start feature is for applying power to the Battery Backup Power Supply and connected
equipment when the Battery Backup Power Supply is off and there is no utility power. Before using
the cold start feature, please make sure the battery is charged. To enable the cold start feature,
press the recessed cold start button with a small pointed object.
Model CSN30C12V-E
WARNING INDICATOR
Battery Backup Power Supply is on utility power.
Battery Backup Power Supply is on battery power.
DC output power is provided by the battery or
utility power.
The battery is not connected or the battery needs to be
replaced.
Green
Yellow
Green
Red
Indicator Color Condition
Front Panel
AC
OUTPUT
BATTERY
Back Panel