Cybertek CPL2000 User manual

Shenzhen Zhiyong Electronics Co., Ltd
www.cybertek.cn
AC/DC Low Frequency Current Probe
CPL2000
(2000A/10kHz)
Shenzhen Zhiyong Electronics Co., Ltd
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd
1
Preface
First of all, thank you for purchasing our products, this instruction manual is the
description about the function, usage, operation attention points, etc. Before use, please
read the instructions carefully and use correctly.
Manual annotation will use the following symbols to distinguish.
To prevent shortage and accident, the circuit under test should be below 600VAC.
Do not test the naked conductor.
Do not touch the conductor under test and the sensor head during testing.
When the oscilloscope is connected with other test terminal, please pay attention to the following
points:
Please use the basic insulation device with proper voltage and pollution range when connecting
the test terminals between CPL2000 and devices.
Do not input voltage surpassing the safety range if the basic insulation of the test terminal does
not meet the requirement.
Please refer to the matters need attention about electronic safety.
Electric shock could occur if the machine or the user’hand is wet during testing.
The sensor head is consisted of precision devices including magnetic core, hall component. The
drastic change of temperature or the external impact could damage the sensor so please avoid
Notice
Warning
Notice
Warning
In the case of wrong operation, the user risk injury. The content under this
mark records the relevant matters needing attention to avoid such dangers.
The user may suffer minor injuries and material damage with the wrong
operation. To avoid such situation, the matters under this mark need attention.
This symbol means it is harmful to the machine and human body; you must
strictly follow the instruction manual to operate.
Note
This symbolizes important note about how to use the machine.
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd
2
vibration or strike during operation.
CPL2000 is neither waterproof nor dustproof. Please do not use it in dusty or wet environment.
The upper and lower touching surface of the sensor head is created by accurate grinding process.
Please try not to damage it or the function will be badly affected.
The current probe has an inner square shape 9V battery. CPL2000 is highly power-consuming so
please use the alkaline battery that can last long.
Comparatively large test error could occur when the power supply is low. When the battery voltage
is lower than 6.5V, the machine will notify the users by a low voltage alarm. Please change the
batteryASAP to ensure the accuracy of testing.
CPL2000 Brief description
Type
Max Current
(rms)
Peak Value
Current
Bandwidth
(-3dB)
Range
Selection
Current
Transfer
Ratio
CPL2000
2000A
3000Apk
10kHz
2000A
1mV/A
200A
10mV/A
Note
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd
3
Index
Preface…………………………………………………………………………………….…….…………1
CPL2000 Brief Description….....………………………………………………….…………..……… …2
Summary…………………………………………………………………………………….……………4
Probe Parts Description……………………………………………………………………………………4
Electronics Specification…………………………………………………………………….………….…5
Operating Method…………………………………………………………………………………………5
Mechanic Specification……………………………………………………………………………………6
Environmental Specification………………………………………………………………………………6
Maintenance…………………………………………………………………………………….…………6
Treatment when irregular occurs …………………………………………………………….……………8
Packing List…………………………………………………………………………………..……………8
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd
4
1.Summary
CPL2000 is a type of current probe that can test AC and DC simultaneously. The current under
test can reach maximum value 2000Arms, peak value 3000Apk, bandwidth 10 kHz (-3dB). With two
range selection (200A and 2000A optional), users can choose the proper range according to the current
value; with auto zero function, users can make use of CPL2000 easily, and the power and battery low
voltage alarm indication light and overload alarm buzzer equipped can notify the users fast. Also,
CPL2000 can be powered by battery or external power supply. Its standard BNC output port allows it to
connect with oscilloscope and other devices, including multi-meter by BNC to Double Banana plug.
CPL2000 is usually used in fields including power frequency measurement, motor drive and power
suppy.
2.Probe Parts Description
Probe
Power Switch
OFF:Probe is turned off and power supply is off.
ON:Probe is turned on and power supply is on
Power Indication Light: Lighted green when power supply switch is ON.
Low Power Indication Light: Lighted red when battery voltage is lower than 6.5V, please change
batteryASAP.
Range Button: Range switching button
Range Indication light: Indicating the current range selection. 2000A and 200Aoptional.
Auto zero button: To test accurately, zero set the probe to prevent the environmental factors such
as earth magnetic field or temperature drift from affecting the result.
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd
5
Auto zero indication light: lighted during zero setting.
Clamp: the current testing clamp, diameter around 54mm.
External power supply port: external DC power supply.
Battery Box: 9V alkaline battery within. Please disconnect from the conductor and oscilloscope,
turn off the probe when user changes the battery.
Accessories
Output Cable (CK-310): 1m
Power SupplyAdapter (CK-612): DC12V/1A
3.Electronics Characteristics
Test Condition: 23℃, 60RH,no nearby current, cable under test through the center during
testing, load impedance 1MΩ
Range
200A
2000A
Max testing current
200Arms
2000Arms
Peak value current
300Apk
3000Apk
Range Sensitivity
10mV/A
1mV/A
Typical Accuracy
(DC,45Hz~66Hz)
±2 %rdg.±5mV
±2 %rdg.±1mV
Bandwidth(-3dB)
DC~10kHz
Operating voltage
CATII 600V
Typical battery type and
service life
9V alkaline cascade battery/ 15 hour
Low power indication light
Lighted red when battery voltage is lower than 6.5 V
Overload indication
Buzzer will be activated when current under test surpass
the range
4.Operating Methods
Set the CM of the oscilloscope to DC, oscilloscope input impedance to 1MΩ. To make number
reading easier, user can change the display unit of the oscilloscope from voltage to current. Set the
corresponding attenuation according to the situation, for example, for probe set 2000A (1mV/A),
oscilloscope should be 1000X, for probe set 200A (10mV/A), oscilloscope should be 100X. User can
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd
6
connect the BNC output port of the probe and input terminal of the oscilloscope using the standard
BNC cable.
Turn on the voltage switch, the indication light should be lighted green.
Press the button to select the proper range according to the value of the current under test.
Attention: Different range corresponds to different attenuation ratio
Press the auto zero button to realize zero set. The buzzer will buzz shortly for twice if auto zero set
successfully, or it will buzz for once, meaning auto zero set fails. One thing need attention is that, the
external magnetic field could have slight effect on the AC zero position of the probe, so user better
not move the probe after zero set complete.
Open the clamp of the current probe and fix the conductor under test
Attention: there’s direction indication on the clamp, the same current direction will generate positive
output, and otherwise it will generate negative output.
Properly set the vertical sensitivity of the oscilloscope to generate stable wave form. When
oscilloscope is set DC CM, user can observe both DC and AC component, but if there’s only AC CM,
onlyAC component will be seen.
5.Mechanic Specification
Size of current clamp
216*115*45mm
Size of output box
137*33*35mm
Operating altitude
0~2000m
Max size of conductor under test
diameter 54mm
Length of the connecting cable between
clamp and box
1m
Length of double-terminal BNC cable
1m
Weight
620g (Battery Excluded)
6.Environmental Specification
Operating temperature
0℃~+50℃
Storing temperature
-20℃~+80℃
Operating relative humidity
0℃~+40℃,Humidity 95%RH;
+40℃~+50℃,Humidity 45%RH
Pollution level
Level 3
7.Maintenance
In the product warranty period, if the product is used normally, the malfunction is caused
by the quality problem and is not dismantled, our company will provide free repairing
service.
Clamp: the clamp should be clean and dry. If there’s a need of cleaning up, please use soft cloth
together with alcohol to erase the dirt. Do not put the clamp in wet environment.
Hand shank: Please clean up the hand shank using clean cloth or sponge. Do not use water to
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd
7
clean the equipment, use alcohol instead and dry it after the treatment.
To guarantee the performance, user can proceed check or calibration once a year.
8.Treatment when irregular occurs
Problem
Possible Reason
Treatment
Unable to test DC, or amplitude
too low
Power supply is off
Turn on the power supply
Oscilloscope is set AC CM
Please set to DC CM
Clamp is not completely closed
Close the clamp completely
Power Indication Light is not
lighted after device is turned on
Battery voltage lower than 6.5V
Change the battery
Amplitude low in all frequency range
The input resistance of other
testing device is 50Ω
Please set the input resistance
over 1MΩ
9.Packing List
PACKING LIST
Name
Number
Current probe
1
9V battery
1
DC12V/1A adapter(CK-612)
1
BNC output cable (CK-310)
1
High class tool kit
1
Instruction manual
1
Warranty card
1
Test report
1
CYBERTEK
SHENZHEN ZHIYONG ELECTRONICS CO., LTD
Addr:RoomA1702, Building 4, TianAn Cyber Park, HuangGe North Road, LongGang
District, ShenZhen City, China
Tel: +86-400 852 0005 / +86-755-86628000
Q Q: 400 852 0005
Fax: +86)0755-8662 0008
Email: cybertek@cybertek.cn © Zhiyong Electronics, 2018
Url: http://www.cybertek.cn Published in China, January 1, 2018
CYBERTEK
Table of contents
Other Cybertek Measuring Instrument manuals

Cybertek
Cybertek OP6031 User manual

Cybertek
Cybertek EM5018 User manual

Cybertek
Cybertek DP6000 Series User manual

Cybertek
Cybertek EM5030 User manual

Cybertek
Cybertek CPL8100A User manual

Cybertek
Cybertek DP6020 User manual

Cybertek
Cybertek CTB20B User manual

Cybertek
Cybertek DP6065 User manual

Cybertek
Cybertek HCP8000 Series User manual

Cybertek
Cybertek CP8000 Series User manual