Shenzhen Zhiyong Electronics Co., Ltd.
1Jaw:CTB20B/CTB200Bdiameter 20mm,CTB500B/CTB1000B diameter 50mm.
2Power indicator: lighted green indicates power on.
3Degaussing indicator: lighted red when degaussing button was pressed. After the degaussing, indicator
will be off.
4Handle auto degaussing button: After frequent usages, the residual field on the probe will influence
the accuracy of the device. Press the button to degauss before the next measurement to improve the
performance.
5Offset adjust button(increase): press to increase offset. Pressing over 2s will continuously increase the
output offset.
6Offset adjust button(decrease): press to decrease offset. Pressing over 2s will continuously decrease
the output offset.
7Power supply wire: Power supply wire connecting with 12V adaptor.
8Output wire: Signal output port connecting test equipment.
9Distribution box auto degaussing button: perform same function as handle degaussing button, Press
the button to degauss before the next measurement to improve the performance.
10 Current direction mark: Current direction should be the same as the mark, or the output will be
negative.
11 Open/Close handle: Control the jaw through this handle
12 Lock push rod: Control the lock and unlock of the jaw.
4. Accessories
Power supply adaptor(CK-612)
5. Product Electronic Specification
f.s. Maximum display value or scale length (symbolizing the rated primary current range)
rdg. Reading value (symbolizing the current value under measurement, or the current value indicated
by the measurement devices)
Proceed measurement under condition of sin wave input, central conductor position and powered by
12V adaptor.
Measuring device of input resistance over 1MΩ
Please correctly degauss zero set before the measurement.