Czur Aura Series User manual

Aura Series User Manual

Chapter 1 Product description....................................................................................2
Contents
1.1 Product summary .................................................................................................2
1.2 Product dimensions ..............................................................................................2
1.3 Product illustration ...............................................................................................3
1.4 Product parameters ..............................................................................................5
1.5 Packaging and accessories ..................................................................................6
Chapter 2 Operating guide
2.1 Table Lamp mode .................................................................................................6
2.2 Scanner mode .....................................................................................................7
2.2.1 Pre-scanning preparations..............................................................................7
2.2.2 Function introduction......................................................................................8
Chapter 3 Troubleshooting
3.1 Table Lamp ...........................................................................................................9
3.2 Scanner ..................................................................................................................9
Chapter 4 Service statement
4.1 After sales service and warranty .......................................................................12
4.2 Contact methods .................................................................................................13
Contents

1
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may
cause undesired operation.
2. Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
The symbol indicates DC voltage.
RECYCLING: This product bears the selective sorting symbol for Waste electrical
and electronic equipment ( WEEE ). This means that this product must be handled
pursuant to European directive 2012/19/EU in order to be recycled or dismantled to
minimize its impact on the environment.
FCC STATEMENT

Chapter 1 Product description
1.1 Product summary
Aura is a new smart scanner released by CZUR that is also a smart table lamp. Aura uses
a MIPS CPU, HD sensors, U-shaped optics, smart voice control, and other high end
components. Aura does not only provide users with vivid HD image quality, it is also a
zero radiation, low frequency, equally distributed light, multi setting table lamp. It is
suitable for education, corporate use, professionals, families, and individuals. It can be
used to scan academic information, books, exams, documents, files, sheets, notes, etc.
The core algorithms of the scanner can flatten curved surfaces, erase finger prints, sort
pages, perform smart trim correction, apply multiple color modes, and other
optimizations; providing users with a rich and varied scanning experience. This is a
complete departure from traditional scanners and copiers, demonstrating the smart
concept of modern scanners. It provides users with smart, highly efficient, energy
saving office equipment.
The table lamp supports automatic operation and smart control from the app. The
lamp has various modes: Natural light mode, Reading/Writing mode, Computer/Phone
mode, Smart night light mode.
2
1.2 Product dimensions(mm)

1.3 Product illustration
1
2
3
4
5
7
10
9
8
11
12
13
14
18
6
20
21
15
17
16
3
19

Explanation:
1, 2, 3, 4, 5 and 6 are the support, base, top shell, LED bulbs, laser light and HD CMOS
lens.
7. Knob:
‒ Long press (> 1s) to switch on/off
‒ Short press to switch between lamp/scanner modes.
‒ Turn to adjust brightness: turn left to dim, turn right to brighten
8. Scanner indicator light:
After activating the device, short press the knob to change modes. When the scanner
indicator light turns on, it has entered “scanner” mode.
9. Lamp indicator light:After activating the device, when the lamp indicator light turns
on, it has entered “lamp” mode.
10. Power indicator light:When the device is plugged into the adapter and receiving
power, the power indicator light is on.
11. “RESET” button
When the device’s working condition is abnormal, press and hold the "RESET" button
for 6s to force it into power off and standby mode.
12. Type A USB port ‒ connect to Foot Pedal.
13. Type B USB port ‒ connect to computer.
14. DC port ‒ connect to power adapter (9 V/1.5 A).
15. Scanning preview area.
16. USB connection successful logo.
17. X/Y pending transfer/transferred quantity (transfer to computer).
18. With the Foot Pedal, place your heel on the ground and press gently with your toes.
(When scanning multiple pages, it is suggested to use the Foot pedal to free your hands
to turn the pages.)
19. Battery indicator (optional)
Charging indicator: In charging state, the LED lights flash. Please insert the adapter to
charge the device in time when only one LED light is on.
Battery percentage: one LED light on means 25% of battery is available, two lights 50%,
three lights 75%, and four lights 100%.
20. Side lights interface
21. Side lights touch button
4

Scanner
1.4 Product parameters
Sensor :14~20 megapixels
Highest resolution 4320*3240~5248*3936
Scanning format: ≤ A3; scanning speed ≈ 2.0 s
Video format: MJPG
Picture format: JPG
Export format: PDF/WORD/EXCEL
32 bit MIPS CPU, HD sensor, LCD screen, Foot pedal
Curved surface flattening, smart correction, trimming,
erase finger marks, detect page turning
Auto scan
XP/Win7/Win8/Win10/Win11 32 bits/64 bits
macOS 10.13 or above
Basic
configuration
Hardware
configuration
Special features
Supported
systems
Table Lamp
16 true white and 16 warm white LEDs
Natural light mode (140-600lx), Reading/Writing mode
(180-800lx), Computer/Phone mode (110-5601x), Smart
night light mode (15-601x)
Natural light mode (4800K), Reading/Writing mode
(4000K), Computer/Phone mode (3000K),Smart night light
mode (3000K)
Natural light, reading and writing, using computer and
phone, Smart night light mode.
Digital audio waves can be used through applets or the
App (In an open and quiet environment, effective distance
is 5 m)
iOS/Android
LED light
specifications
Luminous flux
Color
temperature
range
Switch setting
Control method
App OS
5

Chapter 2 Operating guide
2. Control brightness with the knob; turn right to brighten, turn left to dim.
3. “CZUR” app control.
1. Plug the power adapter into Aura. Long press the knob for > 1 s to start. The default
setting for Aura is table lamp mode. The lamp turns on.
1.5 Packaging and accessories
Product name
Main device
Foot pedal
USB cable
Power adapter
Black work mat
Finger cots
CD
Getting started
guide
Side lights
Battery(optional)
Specifications
CZUR scanner
USB port, cable length 2.0 m
USB port, cable length 1.5 m
Input AC: 100‒240 V 50/60 Hz
Output DC: 9 V/1.5 A
530*415*1.8MM
Left hand, right hand
CD-R,D=120MM
157 g copper print paper 100*83 mm color
printing
Magnetic connector
3000mAh
Quantity (pcs)
1
1
1
1
1
2
1
1
1
1
6
2.1 Table Lamp mode
You can control the lamp with your phone (turn on/off and adjust the light settings
of the lamp). Scan the QR code to download the CZUR app; register and add “Aura
Pro” functions to control the lamp.
Note: The accessories are subject to the actual models, and the above is for reference only.
1)

2.2 Scanner mode
2.2.1 Pre-scanning preparations
1.Connect one end of the USB cable to the computer and the other end to Aura.
2.Connect the Foot Pedal to the base of Aura.
3.
2)
3)
4)
5)
Go to the “Support” page on the official website(www.czur.com). Choose the
corresponding product number, download CZUR Aura software, then install onto
your computer (Windows software can be installed from the CD and will
automatically search for upgrades. MacOS users please download from the official
website). Open the CZUR Aura software and you are ready to scan.
Long press the knob for > 1 s to enter lamp mode by default.
Open the App to freely switch between Natural light mode, Reading /Writing mode,
Computer/Phone mode, and Smart night light mode, turn on/off, and adjust
brightness (the lamp does not respond to app control when turned off).
The table lamp brightness can be adjusted in each mode (except Smart night light
mode,). Turn right to brighten and turn left to dim. Brightness will be restored to the
default setting when you switch modes.
In Smart night light mode, Aura will automatically adjust brightness depending on
the ambient sound level. In Smart night light mode, app control and brightness
adjustment is not supported.
Align the black work mat notch with the Aura base and secure it tightly, and unfold
the Aura until the head case is at 90 degrees to the base (pictured).
4.
5.
Plug the power adapter into Aura and long press the knob for > 1 s to turn on. Short
press the knob again to switch to scanner mode.
7

1.
2.
3.
2.2.2 Function introduction
8
1)
2)
3)
4)
5)
6)
7)
From the LCD screen on the top, check that the black work mat covers the entire
screen. Check that there are no signs of the desktop or edge showing on either
side. (The black work mat is essential. It is used as the basis of the smart
algorithms and must cover the area completely, or there may be errors with image
processing.)
Avoid scanning documents near a window or in bright conditions. External light
will interfere with the brightness of Aura’s laser, diminishing scanning quality.
When scanning books, all three laser lines must be focused on the curve of the
book, or image quality will be affected.
When your fingers are pressed on a book during scanning, you must use the Aura
“finger cots,” or the fingerprint erasing function may be affected.
During image collection, do not move the document or turn the page, otherwise
the scan quality will be affected. From clicking the “Scan” until the laser light is off,
the device is in the process of collecting data, and the operator must not move the
document or turn the page. When the laser light is off, it means that data has been
collected and pages can been moved or turned.
Connect the Foot Pedal to improve scanning efficiency, making scanning easier.
When scanning magazines, coated paper, and other reflective materials,switch the
side lights ON for best effects.
6.Attention
On switching to scanner mode, the LED lamp default is on its brightest setting. By
turning the knob, you can adjust between high, medium, low, and off. Turning to
the right makes the lamp brighter; turning to the left makes the lamp dimmer.
Open the CZUR Aura software and click the scan icon in the bottom right corner to
enter the scan interface. Choose color mode and processing method on the right
and click scan icon to start scanning (please choose the correct processing method
or the results will be affected).
For detailed software information, please visit the “www.czur.com/support”page
on the official website.

1.
1.
2.
3.
Aura will not turn on, the power indicator light is off.
3.2 Scanner
3.1 Table Lamp
Chapter 3 Troubleshooting
Aura will not turn on, the power indicator light is off
Lamp brightness cannot be adjusted
9
2)
1)
2)
1)
2)
App voice control does not work for the lamp
1)Did the phone play the voice control sound?
Make sure it is set to table lamp mode. If it is set to scanner mode, please short
press the knob and change to table lamp mode, then continue.
In Smart night light mode, app control and brightness adjustment is not
supported.
Check if the brightness is set to brightest or dimmest. If it is set to brightest, then
it cannot be made brighter; if it is set to dimmest, then it cannot be made
dimmer.
Check if the power outlet is working normally and if the adapter is connected
properly.
Was there an error with an Aura firmware update? If a firmware update fails,
please contact customer support (contact information is in the end of user
manual).
Check if the power outlet is working normally and if the adapter is connected
properly.
Was the knob pressed for more than 1.5 s?
Was there an error with an Aura firmware update? If a firmware update fails,
please contact customer support (contact information is in the end of user
manual).
1)
2)
3)

10
1)
2)
3)
4)
1)
2)
3)
4)
5)
6)
“CZUR Aura” software cannot be installed or reports an error
3.
2.
4.
Serial number error message
Please check if the serial number was entered correctly: are the numbers and letters
correct? Often times, letters and numbers such as I and 1 can be mistaken for each
other. Note that there is no number 1 (one) in the S/N.
The software supports XP/Win7/Win8/Win10/Win11 and some MacOS versions.
Ensure the serial number has been entered correctly.
Check your anti-virus software or firewalls that may be blocking or stopping the
software. Turn off your anti-virus software or add the Aura software as trusted;
turn off the firewall or lower the security level.
If the software was downloaded from the official website, please ensure the
download was complete, then install the software.
When using Aura for the first time, the CZUR Aura software cannot be started; the
images do not show and it is unable to scan.
Close anti-virus software, security software, or any other defensive software.USB
port on the computer.
Check if the computer’s “device manager” has recognized CZUR Aura. If the
yellow exclamation mark/unknown device appears, right click to update the
drivers or disable then re-activate the device. Restart CZUR Aura software then try
again.
In the device manager, disable other “scanners,” “monitors,” and “cameras,”
then try again.
Restart the computer or use another computer.
Reconnect the USB cable or restart Aura. Restart the CZUR Aura software on the
computer.
Plug into another USB port on the computer. Performance may differ between
each.

Chapter 4 Service statement
1.
2.
3.
4.
5. Distortion, curving, or stretching of the scanned image
4.1 After sales service and warranty
Dear user, thank you for using our smart scanner. To protect your legal rights, please
read and strictly abide by the following standards and precautions.
Ensure the black work mat notch is in position on Aura. The Preview Area cannot exceed
the area of the black work mat. Please see Chapter 2.2.1.
Scanning materials cannot extend beyond the Preview Area. “Scanning materials” refer
to documents, books, files, sheets, notes, identification, name cards, objects, etc.
Does the Preview Area contain objects other than the scanning material? If other
objects are present, the scans will be affected. For example, USB cable, phone,
pen, etc.
All after sales policies of this product follow national after sales guidelines. With
major problems with product quality, refunds are guaranteed within 7 days of
purchase with a one year warranty and lifetime repair.
The warranty includes the Aura device, power adapter, and Foot Pedal. Consumable
materials and appearance are not covered by the warranty.
When the product is brought in for repairs, it must be accompanied by the complete
packaging to ensure its safety and state during transportation.
Subsequent upgrades or updates of the products are subject to change without
prior notice. The company reserves the right of final interpretation of the above
terms.
11
1)
2)
3 )

1)
2)
3)
4)
5)
6)
7)
8)
Battery (optional)
Please do not try to replace the Aura battery by yourself in case it might cause
battery damage, overheating, fire, or personal injury. Aura's lithium battery should
be serviced or recycled by an authorized service provider and must be recycled or
disposed of separately from household waste. Please dispose of the battery in
accordance with local environmental regulations.
Caution risk of explosion if battery is replaced by an incorrect type.Dispose of the
used Batteries according to the instructions.
You can receive tech support and related information through the following
methods.
4.2 Contact methods
12
5. Non warranty conditions
The maximum ambient operating temperature of this product is 40 °C.
Malfunctions or damage caused by incorrect installation or use in a work
environment not specified by the product (e.g., excessive temperature, excessive
humidity, etc.).
Damage caused by parts manufactured by other companies or replacement of
parts by the user.
Damage caused by disaster, accident, or human factors.
Damage due to improper storage (such as vermin, liquid damage, etc.).
Failure or damage caused by unauthorized disassembly, repair, or abuse.
Damage caused by unauthorized repair centers.
Damage or errors caused by the installation and settings of other software.
Damage or errors caused by computer viruses.
6.

13
CZUR TECH CO., LTD
9F, North Wing, West Block, PKU-HKUST ShenZhen-HongKong Institution, Gaoxin South
7th Road, Nanshan District, Shenzhen, China
Room1001,10th Floor, Block A, No.32A Huoju Road, High-tech Industrial Zone, Dalian
City, Liaoning Province, China
Manufacturer: CZUR
After sales address: 2nd Floor, Building 2, Gem Industrial Zone, No. 12, Gem Road,
Yutaitang Village, Tangxia Town, Dongguan City (Zip code 523723)
Support e-mail: support@czur.com
Website: www.czur.com

CZUR TECH CO., LTD.
9F, North Wing, West Block, PKU-HKUST ShenZhen-HongKong Institution,
Gaoxin South 7th Road, Nanshan District, Shenzhen, China
Room1001,10th Floor, Block A, No.32A Huoju Road, High-tech Industrial
Zone, Dalian City, Liaoning Province, China
E-mail: support@czur.com Skype: support@czur.com
www.czur.com
Other manuals for Aura Series