DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL
MODELS
FDMF50VVMG
FDMF71VVMG
FDMF60VVMG
00_CV_3P620957-9A.indd 1 31-Jul-20 2:04:06 PM
00_CV_3P620957-9A.indd 2 31-Jul-20 2:04:06 PM
Read the precautions in this manual carefully
before operating the unit. This appliance is lled with R32.
• Keepthismanualwheretheusercaneasilyndit.
• TheprecautionsdescribedhereinareclassiedasWARNINGandCAUTION.Theybothcontainimportantinformationregarding
safety.Besuretoobserveallprecautionswithoutfail.
WARNING Failuretofollowtheseinstructionsproperlymayresultinpersonalinjuryorlossoflife.
CAUTION Failuretoobservetheseinstructionsproperlymayresultinpropertydamageorpersonalinjury,
whichmaybeseriousdependingonthecircumstances.
Neverattempt. Besuretofollowthe
instructions.
Besuretoestablishanearth
connection.
• Afterreading,keepthismanualinaconvenientplacesothatyoucanrefertoitwhenevernecessary.Iftheequipmentis
transferredtoanewuser,besurealsotohandoverthemanual.
WARNING
• Donotusemeanstoacceleratethedefrostingprocessortoclean,otherthanthoserecommendedbythemanufacturer.
• Theappliancemustbestoredinaroomwithoutcontinuouslyoperatingignitionsources(forexample:openames,an
operatinggasapplianceoranoperatingelectricheater).
• Donotpierceorburn.
• Beawarethatrefrigerantsmaynotcontainanodour.
•
Theappliancemustbeinstalled,operatedandstoredinaroomwiththeminimumrequiredoorarea.Refertotheinstallationmanual
fortheoutdoorunit.Ifthesizeoftheroomwheretheapplianceistobeinstalledhaslessthantheindicatedminimumoorarea,install
itinawellventilatedroom.Maintainaninstallationheightof2.5mormorefromtheoorsurfacetothebottomoftheappliance.
•
To avoidre,explosionorinjury,donotoperatetheunitwhenharmfulgases(e.g.ammableorcorrosive)aredetectedneartheunit.
• Beawarethatprolonged,directexposuretocoolairfromtheairconditioner,ortoairthatistoocoolcanbeharmfulto
yourphysicalconditionandhealth.
• Donotplaceobjects,includingrods,yourngers,etc.,intheairinletoroutlet.Productdamageorpersonalinjurymay
resultduetocontactwiththeairconditioner’shigh-speedfanblades.
• Donotattempttorepair,dismantle,reinstallormodifytheairconditioneryourselfasthismayresultinwaterleakage,
electricshockorrehazards.
• Donotuseammablesprayneartheairconditioner,orotherwiseremayresult.
• Donotusearefrigerantotherthantheoneindicatedontheoutdoorunit(R32)wheninstalling,movingorrepairing.Using
otherrefrigerantsmaycausetroubleordamagetotheunit,andpersonalinjury.
• To avoidelectricshock,donotoperatewithwethands.
• Bewareofreincaseofrefrigerantleakage.Iftheairconditionerisnotoperatingcorrectly,i.e.notgeneratingcoolair,
refrigerantleakagecouldbethecause.Consultyourdealerforassistance.Therefrigerantwithintheairconditionerissafe
andnormallydoesnotleak.
However,intheeventofaleakage,contactwithanakedburner,heaterorcookermayresultingenerationofnoxiousgas.
Donotusetheairconditioneruntilaqualiedservicepersonconrmsthattheleakagehasbeenrepaired.
• Donotattempttoinstallorrepairtheairconditioneryourself.Improperworkmanshipmayresultinwaterleakage,electric
shockorrehazards.Pleasecontactyourlocaldealerorqualiedpersonnelforinstallationandmaintenancework.
• Iftheairconditionerismalfunctioning(givingoffaburningodour,etc.),turnoffpowertotheunitandcontactyourlocal
dealer.Continuedoperationundersuchcircumstancesmayresultinafailure,electricshockorrehazards.
•
Besuretoinstallanearthleakagecircuitbreaker.Failuretoinstallanearthleakagecircuitbreakermayresultinelectricshockorre.
Contents
Read Before Operation
SafetyPrecautions....................................... 1
NamesofParts............................................ 3
Multi Connection
NoteforMultiSystem.................................. 4
Care
CareandCleaning....................................... 5
When the Need Arises
Troubleshooting........................................... 7
Safety Precautions
1
Read Before Operation Read Before Operation
01_EN_3P620957-9A.indd 1 31-Jul-20 2:03:47 PM
• Besuretoearththeunit.Donotearththeunittoautilitypipe,lightningconductorortelephoneearthlead.
Imperfectearthingmayresultinelectricshock.
CAUTION
• Donotusetheairconditionerforpurposesotherthanthoseforwhichitisintended.Donotusetheairconditionerfor
coolingprecisioninstruments,food,plants,animalsorworksofartasthismayadverselyaffecttheperformance,quality
and/orlongevityoftheobjectconcerned.
• Donotexposeplantsoranimalsdirectlytotheairowfromtheunitasthismaycauseadverseeffects.
• Donotplaceappliancesthatproducenakedamesinplacesexposedtotheairowfromtheunitasthismayimpair
combustionoftheburner.
• Donotblocktheairinletsnoroutlets.Impairedairowmayresultininsufcientperformanceortrouble.
• Donotsitontheoutdoorunit,putthingsontheunit,orpulltheunit.Doingsomaycauseaccidents,suchasfallingor
topplingdown,thusresultingininjury,productmalfunctioning,orproductdamage.
• Donotplaceobjectsthataresusceptibletomoisturedirectlybeneaththeindoororoutdoorunits.Undercertain
conditions,condensationonthemainunitorrefrigerantpipes,airlterdirtordrainblockagemaycausedripping,resulting
infoulingorfailureoftheobjectconcerned.
• Afterprolongeduse,checktheunitstandanditsmountsfordamage.Iftheyareleftinadamagedcondition,theunitmay
fallandcauseinjury.
• To avoidinjury,donottouchtheairinletoraluminiumnsoftheindoororoutdoorunits.
• Theapplianceisnotintendedforusebyunattendedyoungchildrenorinrmpersons.Impairmentofbodilyfunctionsand
harmtohealthmayresult.
• Childrenshouldbesupervisedtoensurethattheydonotplaywiththeunitoritsremotecontroller.Accidentaloperationby
achildmayresultinimpairmentofbodilyfunctionsandharmhealth.
• Avoidimpactstotheindoorandoutdoorunits,orotherwiseproductdamagemayresult.
• Donotplaceammableitems,suchasspraycans,within1moftheairoutlet.
Thespraycansmayexplodeasaresultofhotairfromtheindoororoutdoorunits.
• Becarefulnottoletpetsurinateontheairconditioner.Urinationontheairconditionermayresultinelectricshockorre.
• Donotwashtheairconditionerwithwater,asthismayresultinelectricshockorre.
• Donotplacewatercontainers(vases,etc.)abovetheunit,asthismayresultinelectricshockorrehazardsifthey
shouldtoppleover.
• Donotinsertthebatteriesinthewrongpolarity(+/-)orientationasthismayresultinshortcircuiting,re,orbattery
leakage.
• Donotuseanunstablestandatthetimeofoperatingormaintainingtheairconditioner,orotherwiseyoumaytoppleover
orinjureyourself.
•To avoidoxygendepletion,ensurethattheroomisadequatelyventilatedifequipmentsuchasaburnerisusedtogether
withtheairconditioner.
• Beforecleaning,besuretostopunitoperationandturnoffthecircuitbreaker.Otherwise,anelectricshockandinjurymay
result.
• Onlyconnecttheairconditionertothespeciedpowersupplycircuit.Powersuppliesotherthantheonespeciedmay
resultinelectricshock,overheatingandres.
• Arrangethedrainhosetoensuresmoothdrainage.Imperfectdrainagemaycausewettingofthebuilding,furniture,etc.
• Donotplaceobjectsindirectproximityoftheoutdoorunitanddonotletleavesandotherdebrisaccumulatearoundthe
unit.Leavesareahotbedforsmallanimalswhichcanentertheunit.Onceinsidetheunit,suchanimalscancause
malfunctions,smokeorreiftheycomeintocontactwithelectricalparts.
• Donotplaceobjectsaroundtheindoorunit.
Doingsomayhaveanadverseinuenceontheperformance,productquality,andlifeoftheairconditioner.
• Thisapplianceisnotintendedtobeusedbypersonswithreducedphysical,sensoryormentalcapabilities,orwithlackof
operationknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerningtheapplianceusebyperson
responsiblefortheirsafety.Keepoutofchildren’sreachtoensurethattheydonotplaywiththeappliance.
• Forcareandcleaning,callservicepersonnel.
• Locatetheremotecontrollerinplacesoutofreachofchildren.Thewrongoperationoftheremotecontrollermayresultin
injury.
Thisisanappliancethatisnotaccessibletothegeneralpublic.
Precautions relating to area surrounding the indoor and outdoor units
Besuretofollowtheinstructionsbelow.
• Theindoorunitisatleast1mawayfromanytelevisionorradioset(unitmaycauseinterferencewiththepictureorsound).
• Refrainfromusingtheunitsinareaspronetohighlevelsofoilysmoke,suchasakitchen.Waterleakagemayresult.
2
Read Before Operation Read Before Operation
01_EN_3P620957-9A.indd 2 31-Jul-20 2:03:47 PM
Names of Parts
Outdoor Unit
 •Theappearanceoftheoutdoorunitmaydifferbetweendifferentmodels.
Indoor Unit
Earth terminal (inside)
Refrigerant pipes and
inter-unit wire
Air outlet
Air inlet (back and side)
Model name
Drain hose
•Fordetailsonremotecontrolleroperation,refertotheoperationmanualincludedwiththeremotecontroller.
Remote controller
Wired type
Modelname BRC1E63
Wireless type
Modelname BRC086A22
BRC086A2R1
Model name
(Model name plate)
Suction duct
(Field supply)
Suction grille
(Field supply)
Airlter
(Sold separately)
Wiring between the indoor and outdoor units
Drain pan inspection window
Refrigerant piping
Air outlet grille
(Field supply)
Exhaust duct
(Field supply)
Drain discharge device
(built-in)
Drain piping
Remote controller (Wired type)
The appearance of the remote controller
may differ between different models.
Suctionlterchamber
(Sold separately)
3
Read Before Operation Read Before Operation
01_EN_3P620957-9A.indd 3 31-Jul-20 2:03:48 PM

This manual suits for next models

2

Other Daikin Air Conditioner manuals

Daikin EHBH08CB Product information sheet

Daikin

Daikin EHBH08CB Product information sheet

Daikin VRVIII RXYQ Series User manual

Daikin

Daikin VRVIII RXYQ Series User manual

Daikin CTKC25WVMG User manual

Daikin

Daikin CTKC25WVMG User manual

Daikin FTXS50KAVMN User manual

Daikin

Daikin FTXS50KAVMN User manual

Daikin RXM20R5V1B How to use

Daikin

Daikin RXM20R5V1B How to use

Daikin FMDQ50A7V3B User manual

Daikin

Daikin FMDQ50A7V3B User manual

Daikin RXM42M3V1B9 User manual

Daikin

Daikin RXM42M3V1B9 User manual

Daikin Stylish Series User manual

Daikin

Daikin Stylish Series User manual

Daikin Air Conditioner User manual

Daikin

Daikin Air Conditioner User manual

Daikin FDXM25F3V1B9 User manual

Daikin

Daikin FDXM25F3V1B9 User manual

Daikin Altherma EHVH04S23DAV User manual

Daikin

Daikin Altherma EHVH04S23DAV User manual

Daikin SkyAir FCQ24TAVJU User manual

Daikin

Daikin SkyAir FCQ24TAVJU User manual

Daikin FXLQ20PVEB User manual

Daikin

Daikin FXLQ20PVEB User manual

Daikin FTXTA30B2V1BW User manual

Daikin

Daikin FTXTA30B2V1BW User manual

Daikin FTX20JV FTX25JV FTX35JV Instruction manual

Daikin

Daikin FTX20JV FTX25JV FTX35JV Instruction manual

Daikin FVXS60HVMA User manual

Daikin

Daikin FVXS60HVMA User manual

Daikin DPS003 Manual

Daikin

Daikin DPS003 Manual

Daikin FTX50GV Instruction manual

Daikin

Daikin FTX50GV Instruction manual

Daikin O-WCP16-SEP21-2 Owner's manual

Daikin

Daikin O-WCP16-SEP21-2 Owner's manual

Daikin EHBH04DA6V User manual

Daikin

Daikin EHBH04DA6V User manual

Daikin RZQG71L8V1B User manual

Daikin

Daikin RZQG71L8V1B User manual

Daikin ATX25J2V1B User manual

Daikin

Daikin ATX25J2V1B User manual

Daikin FXSN112A2VEB User guide

Daikin

Daikin FXSN112A2VEB User guide

Daikin FTXE25BVMA User manual

Daikin

Daikin FTXE25BVMA User manual

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Taurus Alpatec R750 manual

Taurus Alpatec

Taurus Alpatec R750 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.