•Outdoor Unit • Daikin Altherma flex type• EMRQ-A
1
9
•Heating • Daikin Altherma flex type
18
9 Wiring diagrams
9 - 1 Wiring Diagrams - Single Phase
1TW59926-3
EMRQ14-16A
A1P∼A8P
Printed circuit board
A1P: Main A4P,A7P: Noise filter
A2P: Sub 1 A5P, A8P: Inverter
A3P: Sub 2 A6P,A9P: Fan
BS1∼BS5 Push button switch (Mode, set, return, test, reset)
C1, C63, C66 Capacitor
E1HC, E2HC Crankcase heater (A1P, A3P)
F1U, F2U Fuse (T, 3.15A, 250V) (A1P, A3P)
F1U Fuse (T, 3.15A, 250V) (A2P)
F1U Fuse (8A, DC650V) (A6P, A9P)
F5U Field fuse
F400U Fuse (T, 6.3,250V) (A4P)(A7P)
H1P∼H8P
Pilot lamp (service monitor-orange)
[H2P] Prepare test----Flickering
Malfunction detection----Light up
HAP Pilot lamp (Service monitor green) (A1P A2P A3P)
K1∼K4
K1: Magnetic relay (A5P,A8P)
K3: Magnetic relay (A4P,A7P)
K2: Magnetic contactor (M1C-A5P,M2C-A8P)
K4: Magnetic contactor (M1C-A4P,M2C-A7P)
K1R∼K8R, K11R
Magnetic relay
K1R: Y4S K5R: For option (A2P)
K2R: Y5S K5R Y9S (A3P)
K3R: Y1S (A1P) K6R: Y7S (A2P)
K3R: Y6S (A2P) K7R: E1HC (A1P)
K4R: Y8S K7R: (E2HC) (A3P)
K5R: Y2S (A1P) K11R: Y10S (A3P)
L1R Reactor
M1C, M2C Motor (Compressor)
M1F, M2F Motor (Fan)
PS Switching power supply (A1P, A3P, A5P,A8P)
Q1DI Earth leakage breaker
Q1RP Reverse phase detection circuit (A1P, A3P)
R10 Resistor (current sensor) (A6P, A7P)
R50, R59 Resistor (A5P,A8P)
R90 Resistor (current sensor) (A5P,A8P)
R95 Resistor (current limiting) (A5P,A8P)
R1T∼R15T
R31T, R32T
Thermistor
R1T: Air (A1P) R8T: Suction 1
R1T: Fin (A5P,A8P) R9T: Liquid
R2T: H/E gas 1 R10T: Suction 2
R31T: M1C Discharge R11T: H/E gas 2
R32T: M2C Discharge R12T: H/E deicer 2
R4T: H/E deicer 1 R13T: Subcool H/E gas 2
R5T: Subcool H/E gas 1 R14T: Liquid 2
R6T: Subcool H/E Liq R15T: H/E Liquid 2
R7T: H/E Liquid 1
S1NPH Pressure sensor (high)
S2NPL Pressure sensor (Pressure sensor (low))
S1PH, S2PH Pressure switch (high)
T1A Current sensor
SD1 Safety devices input (A1P, 3AP)
V1R Diode bridge (A5P,A8P) Power module (A6P,A9P)
V2R Power module (A5P,A8P)
X1A∼X9A Connector
X1M Terminal strip (Power supply)
X1M Terminal (Control) (A1P,A3P)
X2M Terminal strip (Relay)
Y1E Electronic expansion valve (Main 1)
Y2E Electronic expansion valve (Subcool 1)
Y3E Electronic expansion valve (Main 2)
Y4E Electronic expansion valve (Charge)
Y5E Electronic expansion valve (Subcool 2)
Female connector WHT
Male connector BLU
(Note 5) Indoor
To
in/d
unit
To
out/d
unit
To
multi
unit
(Note4)
Male connector BLU
Female connector WHT
Female connector WHT
Male connector BLK
(Note 4)
POWER
SUPPLY
3/N ∼380-415V 50Hz
El. Compo. Box 2 El. Compo. Box 1
Front layer
Rear layer
Position of M1,2C, M1,2F
El. Compo. Box 2 El. Compo. Box 1
Outer shell
Wiring diagram
sticker
Detail of M1C, M2C
Notes:
1 This wiring diagram only applies to the outdoor unit
2g: Field wiring
3D: Terminal strip F: Fixed connector
R: Protective earth (screw) G: Terminal
4 When using the option adaptor, refer to the installation manual
5 Refer to the installation manual for connection wiring to indoor - outdoor unit transmission F1-F2 and
how to use BS1-BS5
6 Do not operate the unit by short-circuiting any protection device S1Ph, S2PH.
7 BLK = Black RED = Red YLW = Yellow WHT = White PNK = Pink
BRN = Brown GRY = Grey GRN = Green ORG = Orange BLU = Blue
14,16 HP
To multi
unit
Front layer
Rear layer
Y1S∼Y10S
Solenoid valve
Y1S: RMTG Y6S: RMTT
Y2S: 4 way valve Y7S: RMTO
Y3S: RMTL Y8S: 4 way valve (pipe)
Y4S: hot gas Y9S: 4 way valve (H/E 2)
Y5S: EV Bypass 1 Y10S: EV Bypass 2
Z1∼Z8C Noise filter (Ferrite core)
Z1F Noise filter (with surge absorber) (A4P,A7P)
Connector for optional parts
X7A Refer to the installation manual for connection wiring to indoor -
outdoor unit transmission F1-F2 and how to use BS1-BS5 (A2P)
X9A Power supply (Adapter) (A2P)
X37A Power supply (Adapter) (A3P)