Specifications SiBE041401E
7Specifications
50 Hz, 220 - 230 - 240 V
Note: The data are based on the conditions shown in the table below.
Model
Indoor Unit FTXG50LV1BW FTXG50LV1BS
Outdoor Unit RXG50L2V1B RXG50L2V1B
Cooling Heating Cooling Heating
Capacity
Rated (Min. ~ Max.)
kW 4.8 (1.7 ~ 5.3) 5.8 (1.7 ~ 6.5) 4.8 (1.7 ~ 5.3) 5.8 (1.7 ~ 6.5)
Btu/h 16,400 (5,800 ~ 18,100) 19,800 (5,800 ~ 22,200) 16,400 (5,800 ~ 18,100) 19,800 (5,800 ~ 22,200)
kcal/h 4,130 (1,460 ~ 4,560) 4,990 (1,460 ~ 5,590) 4,130 (1,460 ~ 4,560) 4,990 (1,460 ~ 5,590)
Running Current (Rated) A6.5 - 6.2 - 5.9 7.4 - 7.1 - 6.8 6.5 - 6.2 - 5.9 7.4 - 7.1 - 6.8
Power Consumption
Rated (Min. ~ Max.) W1,360 (370 ~ 1,880) 1,589 (310 ~ 2,490) 1,360 (370 ~ 1,880) 1,589 (310 ~ 2,490)
Power Factor (Rated) %95.1 - 95.4 - 96.0 97.6 - 97.3 - 97.4 95.1 - 95.4 - 96.0 97.6 - 97.3 - 97.4
EER (Cooling) / COP (Heating)
Rated (Min. ~ Max.) W/W 3.53 (4.59 ~ 2.82) 3.65 (5.48 ~ 2.61) 3.53 (4.59 ~ 2.82) 3.65 (5.48 ~ 2.61)
Piping
Connections
Liquid mm φ6.4 φ6.4
Gas mm φ12.7 φ12.7
Drain mm φ18.0 φ18.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m30 30
Max. Interunit Height Difference m20 20
Chargeless m10 10
Amount of Additional Charge of
Refrigerant g/m 20 20
Indoor Unit FTXG50LV1BW FTXG50LV1BS
Front Panel Color White Silver
Airflow Rate
H
m³/min
(cfm)
10.9 (385) 12.6 (446) 10.9 (385) 12.6 (446)
M8.9 (313) 10.5 (372) 8.9 (313) 10.5 (372)
L6.8 (239) 8.1 (284) 6.8 (239) 8.1 (284)
SL 3.6 (128) 5.0 (176) 3.6 (128) 5.0 (176)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W29 29
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A0.16 - 0.16 - 0.16 0.21 - 0.21 - 0.21 0.16 - 0.16 - 0.16 0.21 - 0.21 - 0.21
Power Consumption (Rated) W33 - 33 - 33 43 - 43 - 43 33 - 33 - 33 43 - 43 - 43
Power Factor (Rated) %93.8 - 89.6 - 85.9 93.1 - 89.0 - 85.3 93.8 - 89.6 - 85.9 93.1 - 89.0 - 85.3
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 303 × 998 × 212 303 × 998 × 212
Packaged Dimensions (H × W × D) mm 322 × 1,101 × 389 322 × 1,101 × 389
Weight (Mass) kg 12 12
Gross Weight (Gross Mass) kg 16 16
Sound
Pressure
Level H / M / L / SL dB(A) 46 / 40 / 35 / 32 47 / 41 / 35 / 32 46 / 40 / 35 / 32 47 / 41 / 35 / 32
Sound Power Level dB 60 60 60 60
Outdoor Unit RXG50L2V1B RXG50L2V1B
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 2YC36GXD 2YC36GXD
Motor Output W1,100 1,100
Refrigerant
Oil
Type FVC50K FVC50K
Charge L0.395 0.395
Refrigerant Type R-410A R-410A
Charge kg 1.60 1.60
Airflow Rate Hm³/min
(cfm)
49.8 (1,758) 44.8 (1,581) 49.8 (1,758) 44.8 (1,581)
SL 42.6 (1,504) 38.3 (1,352) 42.6 (1,504) 38.3 (1,352)
Fan Type Propeller Propeller
Motor Output W53 53
Running Current (Rated) A6.34 - 6.04 - 5.74 7.19 - 6.89 - 6.59 6.34 - 6.04 - 5.74 7.19 - 6.89 - 6.59
Power Consumption (Rated) W1,327 - 1,327 - 1,327 1,546 - 1,546 - 1,546 1,327 - 1,327 - 1,327 1,546 - 1,546 - 1,546
Power Factor (Rated) %95.1 - 95.5 - 96.3 97.7 - 97.6 - 97.7 95.1 - 95.5 - 96.3 97.7 - 97.6 - 97.7
Starting Current A7.4 7.4
Dimensions (H × W × D) mm 735 × 825 × 300 735 × 825 × 300
Packaged Dimensions (H × W × D) mm 797 × 992 × 437 797 × 992 × 437
Weight (Mass) kg 48 48
Gross Weight (Gross Mass) kg 52 52
Sound
Pressure
Level H / SL dB(A) 48 / 44 48 / 44 48 / 44 48 / 44
Sound Power Level dB 63 63 63 63
Drawing No. 3D086755 C: 3D086759
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling Heating Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB / 24°CWB Indoor ; 20°CDB
Outdoor ; 7°CDB / 6°CWB 5 m