› Ceiling and floor installa on op on
› Automa c air swing
› Flexible installa on
› Auto random restart with last-state-memory
› Be er serviceability
› Wireless handset BRC52A62 is supplied as standard
FL15/20/25/28EXV1
R15CXV1 R20/25/28CXV1 R30/35/40DXV1
R40/50/61DXY1
FH62CXV1
Specifica on for Ceiling Conver ble & Ceiling Exposed - Cooling only (R22)
FL35/40/50EXV1
FL15EXV1 FL20EXV1 FL25EXV1 FL28EXV1 FL28EXV1
R15CXV1 R20CXV1 R25CXV1 R28CXV1 R30DXV1
Btu/h 12000 19000 24000 28000 28000
01280128030707550253W
20.349.237.299.237.2W/W
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
064/065/046064/065/046094/035/085604/064/025053/683/805MFCwolF riA
Sound Pressure Level dBA 48/43/41 48/46/43 50/47/46 56/51/44 56/51/44
812812812812812mmthgieH
08010801080108010801mmhtdiW
036036036036036mmhtpeD
5252323232gkthgieW teN
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
8585251594ABdleveL erusserP dnuoS
258357357156045mmthgieH
0301558558558007mmhtdiW
004823823823052mmhtpeD
9575757482gkthgieW teN
Pipe Connec 25.925.925.953.653.6mmdiuqiL -no
Pipe Connec 88.5188.5188.5188.5107.21mmsaG -no
Nominal Cooling Capacity
Nominal EER
IndoorOutdoor
Indoor Model Name
Outdoor Model Name
FL35EXV1 FL40EXV1 FL40EXV1 FL50EXV1 FH62CXV1
R35DXV1 R40DXV1 R40DXY1 R50DXY1 R61DXY1
Btu/h 33500 37000 38000 47500 56000
014610093104111008010089W
39.267.239.258.223.3W/W
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
0001/0231/0551959/2801/5121778/389/0011778/389/0011966/357/048MFCwolF riA
Sound Pressure Level dBA 48/47/44 52/47/46 52/47/46 52/50/49 56/53/46
582062062062062mmthgieH
30916871835183510231mmhtdiW
086436436436436mmhtpeD
0785545483gkthgieW teN
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50
1685858585ABdleveL erusserP dnuoS
258258258258258mmthgieH
03010301030103010301mmhtdiW
004004004004004mmhtpeD
10595gkthgieW teN 100100 108
Pipe Connec 07.2125.925.925.925.9mmdiuqiL -no
Pipe Connec 50.9150.9150.9150.9150.91mmsaG -no
Nominal Cooling Capacity
Nominal EER
IndoorOutdoor
Indoor Model Name
Outdoor Model Name
Piping Length
Piping Eleva on
m
m
12
5
15
8
15
8
15
8
45
25
Piping Length
Piping Eleva on
m
m
45
25
45
25
45
25
45
25
35
15
3
Ceiling Exposed C Series (50Hz)
1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB.
2. Pre-charged refrigerant amount is based on standard pre-charged piping length of 7.5m.