Danfoss PVG 16 PVH/Covers User manual

Other manuals for PVG 16 PVH/Covers

3

Other Danfoss Control Unit manuals

Danfoss EKC 102A User manual

Danfoss

Danfoss EKC 102A User manual

Danfoss EV251B Installation instructions manual

Danfoss

Danfoss EV251B Installation instructions manual

Danfoss AVTB User manual

Danfoss

Danfoss AVTB User manual

Danfoss PVG 16 PVH/Covers User manual

Danfoss

Danfoss PVG 16 PVH/Covers User manual

Danfoss ASV-I User manual

Danfoss

Danfoss ASV-I User manual

Danfoss AB-QM DN 125 User manual

Danfoss

Danfoss AB-QM DN 125 User manual

Danfoss TEA 20 User manual

Danfoss

Danfoss TEA 20 User manual

Danfoss AK-CC 550A Instruction Manual

Danfoss

Danfoss AK-CC 550A Instruction Manual

Danfoss MSV-F2 DN Series User manual

Danfoss

Danfoss MSV-F2 DN Series User manual

Danfoss AMZ 112 User manual

Danfoss

Danfoss AMZ 112 User manual

Danfoss DSV 10 User manual

Danfoss

Danfoss DSV 10 User manual

Danfoss KP 15 User manual

Danfoss

Danfoss KP 15 User manual

Danfoss EVR 2 User manual

Danfoss

Danfoss EVR 2 User manual

Danfoss AMER 230 V User manual

Danfoss

Danfoss AMER 230 V User manual

Danfoss ADAP-KOOL AK-CT 200A User manual

Danfoss

Danfoss ADAP-KOOL AK-CT 200A User manual

Danfoss POV Series User manual

Danfoss

Danfoss POV Series User manual

Danfoss EV250B NC Installation instructions manual

Danfoss

Danfoss EV250B NC Installation instructions manual

Danfoss SVA-S 6-10 User manual

Danfoss

Danfoss SVA-S 6-10 User manual

Danfoss 176F3417 User manual

Danfoss

Danfoss 176F3417 User manual

Danfoss ASV-PV series User manual

Danfoss

Danfoss ASV-PV series User manual

Danfoss PVG 32 Manual

Danfoss

Danfoss PVG 32 Manual

Danfoss SVA-S 15-200 Series User manual

Danfoss

Danfoss SVA-S 15-200 Series User manual

Danfoss ASV-PV series User manual

Danfoss

Danfoss ASV-PV series User manual

Danfoss MSV-C User manual

Danfoss

Danfoss MSV-C User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

MOTECK CB4M-S user guide

MOTECK

MOTECK CB4M-S user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

V310175.A
P301 776
PVS
PA
7-9Nm
[61-79 lbf•in]
PVM
PVHC
PVB
PVP
Q max: P A
Q max: P B
Installation Guide
PVG 16
Electrical Actuating Module PVHC
© Danfoss A/S, 2014-11 L1407359 • Rev AB • Nov 2014 1
L1407359
L1407359
Oliestrømmens retning for
standard monterede grupper
Oil ow direction for standard
assembled groups
Richtung des Ölstroms für
Standard-Baugruppen
Sens du débit pour ensembles
standard
Tekniske data
Technical data
Technische Daten
Caractéristiques Techniques
PVHC er produceret i et miljø, hvor der benyttes mineralsk hydraulikolie
The PVHC is produced in an environment using mineral based hydraulic oil
Das PVHC wird in einer mineralbasierten Hydrauliköl-Umgebung produziert
Le PVHC est fabriqué dans un environnement qui utilise de l’huile hydraulique à base minérale
Oil viscosity
Olieviscositet
Oil viscosity
Ölviskositet
Viscosité de huille
Range: 12 - 75 mm2/s [65 - 350 SUS]
Min.: 4 mm2/s [40 SUS]
Max.: 400 mm2/s [2130 SUS]
Filtering
Filtering in the
hydraulic system Max. permissible degree of contamination
(ISO 4406), 1999 version): 23/19/16
Temperature
Temperatur range
Ambient Min: -30°C to 80°C [-22 to 176°F]
Medium Max: -20°C to 80°C [-4 to 176°F]
Parameter Control range
12 V 24 V
Controller output
current range 0 - 1200 mA 0 - 600 mA
Spool resistance 1.0 Ω ± 5% 0.25 Ω ± 5%
Pressure control range 5 to 15 bar [72.5 to 217.5 psi]
Pilot pressure
Pilottryk (over tanktryk)*
Pilot pressure (over tank)*
Pilotdruck (über Tank)*
Pression pilote (resérvoir)*
Nom: 25 bar [363 psi]
Min: 21 bar [305 psi]
Max: 25 bar [363 psi]
*Anvendes sammen med hydraulisk aktiverede glidere
* Designed to be used with hydraulic activated spools
* Entworfen, um mit hydraulisch betriebenen Schieber verwendet zu werden
* Conçu pour une utilisation avec des tiroirs d’activation hydraulique
Max tank pressure
Port T Static 25 bar [363 psi]
Port T Dynamic 30 bar [435 psi]
Enclosure
Protection class
Deutsch DT IP 67
P301 120
UDC (A)
UDC (B)
1
1
6
6
Q
L/min [US gal/min]
1 2 3 4 5
12
345
67
PVE
Us/UDC
0.25
0.50
0.75
SP VDC
3.752.501.25
0.50
P
VM
mm
10
20
30
40
50
60
70
[10]
[15]
[5]
[0.04] [0.08] [0.12] [0.16] [0.2][0.04][0.08]
[0.12]
[0.16][0.2][0.24]
[0.28] [in]
AA
A
B
C
D
P005 598E
0
400
200
600
1200
800
1000
1400
Current in mA
Spool stroke, mm
5
4
3
2
1
1600
400
200
600
1200
800
1000
1400
1600
200
100
300
600
400
500
700
800
200
100
300
600
400
500
700
800
@ 12V
@ 24V
P301 775.A
Ideal curve
Hysteresis
280/560 mA 500/1000 mA280/560 mA500/1000 mA
Parameter Control range
12 V 24 V
Current 1 - 1200 mA 0 - 600 mA
Pressure control range 5 to 15 bar [72.5 to 217.5 psi]
2 L1407359 • Rev AB • Nov 2014 © Danfoss, 2014-11
The ideal curve is determined by the main spool neutral spring.
The hysteresis is aected by viscosity, friction, ow forces, dither frequency and modulation frequency.
Aktivering
Activation
Betätigung
Commande
Deutsch Version
Deutsch version
Pos. Description Qty Deutsch code numbers
1Housing 1DT06-2S
1Lock Part 1W2S
1Pin Contact 2 0462-201-16141 when SOC 16-18 AWG*
2 0462-209-16141 when SOC 14-16 AWG*
V310 475.A
5 [0.197]
8 ±0.5 Nm
[70 ±4.4 lbf •in]
V310 004.A
1
V310 017.A
4 [0.16]
3 Nm
[26.5 lbf•in]
4 [0.16] 3 Nm
[26.5 lbf•in]
© Danfoss, 2014-11 L1407359 • Rev AB • Nov 2014 3
NB:
Pakningen i PVHC stikket samt pakningerne til
de enkelte ledninger, er afgørende for at korrekt
tæthed af stikket opnås.
NB:
The seal in the PVHC connector and the seals for
individual conductors are crucial for correctly seal-
ing the connector.
NB:
Die Dichtung im PVHC-Stecker sowie die Dichtun-
gen für die einzelnen Drähte sind für die Dichtheit
des Steckers von entscheidendem Einfluss.
NB:
Le joint de la prise PVHC ainsi les joints de chaque
conducteur, jouent un rôle essentiel dans la qualité
de l'étancheité de la prise.
Montage af PVHC
Installation of PVHC
Montage von PVHC
Installation de PVHC
Montage af magnetventilen som reservedel
Installation of the solenoid valve as spare part
Montage von dem Magnetventil als Ersatzteil
Installation de l'electrodistributeur de rechange
Tilslutning
Connection
Anschluß
Raccordement
39 [1.535]
27 [1.063]
29.4
[1.157]
18.6
[0.732]
74
[2.913]
92
[3.622]
2.5
[0.098]
66.5
[2.618]
34
[1.339]
100.5
[3.957]
6
[0.236]
5.5
[0.217]
V310 474.A
6
[0.236]
4 L1407359 • Rev AB • Nov 2014 © Danfoss, 2014-11
Dimensioner for Deutsch version
Dimensions for Deutsch version
Abmessungen für Deutsch Versionen
Encombrements poor Deutsch Version
© Danfoss, 2014-11 L1407359 • Rev AB • Nov 2014 5
6 L1407359 • Rev AB • Nov 2014 © Danfoss, 2014-11
WAdvarsel
Alle mærker og typer af retningsventiler – også proportional ventiler – kan svigte og forårsage alvorlig skade. Det er derfor vigtigt
at analysere maskinen i alle enkeltheder.
Da proportionalventiler anvendes under mange forskellige driftsbetingelser og i mange forskellige maskiner, er det alene maskin-
producentens ansvar at træe det endelige produktvalg og sikre at samtlige maskinens krav til ydelse, sikkerhed og advarsler er
opfyldt.
Ved valg af reguleringssystem- og sikkerhedniveau- kan man f.eks. støtte sig til ISO 13849 (sikkerhedsrelaterede bestanddele i reg-
uleringssystemet).
WWarning
All makes and all types of directional control valves – inclusive proportional valves – can fail and cause serious damage. It is there-
fore important to analyse all aspects of the application.
Because the proportional valves are used in many dierent operation conditions and applications, the manufacturer of the appli-
cation is responsible for making the nal selection of the products- and assuring that all performance, safety and warning require-
ments of the application are met.
The process of choosing the control system – and safety level – could e.g. be governed by ISO 13849 (Safety related parts of con-
trol system).
WWarning
Alle Fabrikate und Typen von Wegeventilen – einschlieβlich proportionalventile – können versagen und schlimme Unfälle verursa-
chen. Es ist daher wichtig, die Anwendung in allen Details zu analysieren.
Weil proportionalventile unter vielen unterschiedlichen Arbeitsbedingungen und in vielen verschiedenen Anwendungen benutzt
werden, trägt allein der Maschinenhersteller die verantwortung für seine endgültige wahl von produkt, und er ist ebenfalles dafür
verantwortlich, dass alle leistungs-, sicherheits- und warnungsanforderungen an seine maschine erfüllt sind.
Zur wahl vom Reglersystem und sicherheitsniveau kann man sich z.b. auf ISO 13849 stützen.
WAvertissement
Tous les distributeurs – y compris les distributeurs proportionnels – peuvent tomber en panne et entrainer de sérieux dommages.
C'est la raison pour laquelle il est important d'analyser chaque aspect de l'application. Les vannes proportionnelles étant utilisées
dans de nombreuses conditions d'exploitation et applications diérentes, le fabricant de l'application porte l'entiére respon-
sabilité de la sélection nale des produits et du respect des exigences en matiére de rendement, de sécurité et d'avertissement. Le
choix du systéme de commande – et du niveau de sécurité – peut étre fait par exemple sur la base de la norme ISO 13849 (parties
du systéme de commande relatives á la sécurite).