0 3 0 0
- Delay setting
-At each pressure of the SET pushbutton, the user can run throughthe options of the selected level.
OR 1 2 3 Dig1 Dig2 Dig3 Dig4 + SET -
d - 0 0
d - 0 5
d - 1 0
d - 2 0
d - 3 0
d - 4 0
- The delay value setting is in common to both outputs.
- When a delay value, different from zero, is set, the outputs will be maintained active for a
minimum time equal to the number of milliseconds visualised on the display.
- Visualisation of the channel 1 data
-At each pressure of the SET pushbutton, the user can run throughthe options of the selected level.
OR 1 2 3 Dig1 Dig2 Dig3 Dig4 + SET -
C H - 1
THRESHOLD 1 9 4 5
MODE L/d - O n
- Visualisation of the channel 2 data
At each pressure of the SET pushbutton, the user can run through the options of the selected
level.
OR 1 2 3 Dig1 Dig2 Dig3 Dig4 + SET -
C H - 2
THRESHOLD 1 9 4 5
MODE L/d - O n
- Serial output deactivation
At each pressure of the SET pushbutton, the user can run through the options of the selected
level.
OR 1 2 3 Dig1 Dig2 Dig3 Dig4 + SET -
S - o n
S - o f
- Memorisation of the parameters set
OR 1 2 3 Dig1 Dig2 Dig3 Dig4 + SET -
S A
E
- Pressing the SET pushbutton (the SAVE message blinks for 2s, 4Hz) all the changed values
are saved and the user exits fromthe menu, and returns to the normal mode.
- One of the +/- pushbuttons has to bepressed to return to the setting menu.
- Exit from the parameter setting menu
After a 10 s inactivity of the pushbuttons, the sensor returns to the normal mode visualising the
distance.
REMOTE FUNCTION
KEYLOCK function (SET pushbutton block)
The keyboard block function is activated at powering on, connecting the SYNC terminal to the positive
power supply (+Vdc) for at least 1 s.
After the first second, the SYNC input is ready for the normal synchronisation operations (refer to next
paragraph)
To deactivate the keyboard block, the sensor has to be turned off and re-powered maintaining the
SYNC wire not connected or ground connected (GND).
SYNC input (synchronisation)
The connection of the SYNC wire to +Vdc corresponds to the passive logic status while SYNC not
connected or connected to 0 V corresponds to the active logic status.
SYNC passive = +Vdc ; SYNC active = 0V
The synchronisation signal allows to calculate the beginning and ending instants of themeasurement.
The reading cycle begins after the transition of the SYNC signal from passive to active and the sensor
outputs are updated after max. 400μs.
All the outputs are deactivated after max. 400μs from the active – passive transition.
The SYNC wire is used also to determine the transmission direction when the RS485 serial connection
is used.
RS485 serial connection
The serial communication parameters are: 9600 baud, non-parity, 8 data bits, 1 stop bit.
The refresh time of the serial port is 35 ms.
The SYNC input is used to determine the communication direction, and in particular if low (active)
direction S80->User, if high (passive) User->S80.
With SYNC active, the sensor continuously transmits the detecteddistance value (with a precision of
14bit) by means of a binarydata format. 3 byte are used; one with bit 0 at logic level 1 identifies the less
important byte, second with bit 6 atlogic level 1 and bit 7 at logic level 0 identifies intermediate byte,
third with bit 6 at logic level 1 and bit 7 at logic level 1 identifies more important byte.
7 0
1
1 1 0 0 0 D13 D12
7 0
1
0 1 D11 D10 D9 D8 D7
7 0
0
D6 D5 D4 D3 D2 D1 D0
Low signal received condition, corresponding to “FFFF” display indication, is represented on RS485
serial connection by the following sequence:
7 0
1
1 1 0 1 1 1 1
7 0
1
0 1 1 1 1 1 1
7 0
0
1 1 1 1 1 1 1
Out of range condition, corresponding to “HHHH” or “LLLL” display indication, is represented on RS485
serial connection by the following sequence:
7 0
1
1 1 0 0 0 0 0
7 0
1
0 1 0 0 0 0 0
7 0
0
0 0 0 0 0 0 0
The RS485 serial interface allows also the complete remote control of the sensor.
All the commands have to be sent via terminal in an ASCII format according to thefollowing:
-Receipt of the channel status:
At any moment, at the receipt of the ‘r <CR> <LF>’ remote command (and SYNC passive), the
sensor configuration is restored.
-Remote configuration:
The commands available are:
@ <CR> <LF> beginning of the remote setting mode (and SYNC passive)
c1<CR> <LF> channel 1 selection
vxxxx <CR> <LF> distance selection, with xxxx {0…4095}
bx<CR> <LF> dark/light mode selection, with x {1, 2}
b1 = Dark
b2 = Light
e <CR> <LF> memorisation of the configuration sequence.
q <CR> <LF> exit from remote setting without saving the configuration.
At the receipt of the q <CR> <LF> or e <CR> <LF> commands, the sensor visualises ok <CR>
<LF>.
-Delay configuration:
The commands available are:
@ <CR> <LF> beginning of the delay configuration (and SYNC passive)
dx<CR> <LF> delay selection, with x {0, 1, 2, 3, 4, 5}
d0 = 0 ms d3 = 20 ms
d1 = 5 ms d4 = 30 ms
d2 = 10 ms d5 = 40 ms
e <CR> <LF> memorisation of the new delay value
q <CR> <LF> exit from the delay configuration without saving the configuration.
At the receipt of the q <CR> <LF> or e <CR> <LF> commands, the sensor visualises ok <CR>
<LF>.
NOTE: the single digits have to be distanced amongst themselves at least 1 ms, during the
command transmission.
DETECTION DIAGRAMS
SAFETY WARNINGS
All the safety electrical and mechanical regulations and laws have to be respected during sensor
functioning. The sensor has to be protected against mechanical damages.
Place the given labels in a visible position close to the laseremission.
Do not look directly into the laserbeam!
Do not point the laser beam towards people!
Eye irradiation for over 0.25 seconds is dangerous; refer to class 2 standard (EN60825-1).
These sensors are not conform to safety applications!
This product is intended for indoor use only.
The sensors are NOT safety devices, andso MUST NOT be used in the safety control of
the machines where installed.
DECLARATION OF CONFORMITY
We Datalogic Automation declare under our sole responsibility that these products are conform to the
2004/108/CE and successive amendments.
WARRANTY
Datalogic Automation warrants its products to be free from defects.
Datalogic Automation will repair or replace, free of charge, any product found to be defective during the
warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of Datalogic
Automation products.
DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification.