Dawson Tools DDM190D User manual

Dawson DDM190D
Digital Multimeter
User’s Manual

1
TABLE OF CONTENTS
LIMITED WARRANTY AND LIMITATION OF
LIABILITY ..................................................... 3
Out of the Box.............................................3
Accessories.................................................4
Safety Information .....................................7
Certification ...............................................7
INTRODUCTION ........................................... 7
Overview.....................................................7
Figures and Components ............................8
Buttons and Components.........................8
Display Description.................................10
USING THE METER..................................... 10
Preparation ..............................................10
DC/AC Voltage Measurement ..................11
DC/AC Current Measurement ..................12
Resistance Measurement.........................13
Diode Test ................................................14
Continuity.................................................15

2
Logic Test .................................................16
Data Hold .................................................17
Maximum and Hold .................................17
Auto Off....................................................17
SPECIFICATIONS ........................................ 18
General Specification................................18
Technical Specification .............................19
MAINTENANCE AND REPAIR ..................... 23
Repair.......................................................23
Test Leads Replacement...........................24
Replacing Batteries ..................................24
CONTACT DAWSON................................... 25
FEATURES...................................... Back Page

3
LIMITED WARRANTY AND
LIMITATION OF LIABILITY
This instrument from Dawson Tools Inc. will be free from defects
in workmanship and material for three years from the date of
original purchase. This warranty does not cover defects resulting
from damage caused by the user such as drops, neglect, misuse,
unauthorized alteration, usage outside of specified conditions,
contamination, or improper repair/maintenance. To receive
service on the instrument if it becomes necessary during the
warranty period, contact your nearest Dawson authorized service
center at (800) 898-6991 or visit www.DawsonTools.com to
obtain a return authorization (within the US only). A return
authorization is necessary before returning any instrument to
Dawson; no service will be provided without a return
authorization. The user is responsible for properly packing the
unit and charges such as shipping, freight and insurance charges.
The extent of Dawson's liability is limited solely to the
repair/replacement of the instrument. The above warranty in its
entirety is inclusive and no other warranties, written or oral, are
expressed or implied.
Out of the Box
Check the Meter and accessories thoroughly before using
the Meter. Contact your local distributor if the Meter or
any components are damaged or malfunction.

4
Accessories
Test Leads 1pc
Alligator Clip & cable 1pc
1.5V AAA Battery 2pcs
Case 1pc
User’s Manual 1pc
Safety Information
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK,
PRODUCT DAMAGE OR PERSONAL INJURY, PLEASE
FOLLOW THE SAFETY INSTRUCTIONS DESCRIBED IN THE
USER MANUAL. READ THE USER MANUALS BEFORE
USING THE METER.
WARNING
TO ENSURE SAFE OPERATION AND LIFE OF THE METER,
DO NOT PLACE THE METER IN ANY ENVIRONMENT WITH
HIGH PRESSURE, HIGH TEMPERATURE, DUST, EXPLOSIVE
GAS OR VAPOR.

5
Avoid shaking, dropping or any kind of
impacts when using or transporting the Meter.
To avoid electric shock or personal injury,
repairs or servicing not covered in this manual
should be performed only by qualified
personnel.
Avoid direct exposure to sunlight to ensure
extended life of the Meter.
Do not place Meter in a strong magnetic field;
this may cause false readings.
Use only the batteries indicated in the
Technical Spec.
Avoid exposing batteries to humidity. Replace
batteries as soon as the low battery indicator
appears.
Please keep the original packing for future
shipping purposes (ex. Calibration)
After opening the box, check for any damage
during delivery.

6
Safety Symbols
Important safety information, please refers
to the user’s manual
Earth ground
Indicates compliance with requirements for
double insulation
Fuse must be replaced with ratings specified
in the manual.
Important Safety Information
Never use the Meter to measure voltages that
might exceed 600V DC/AC above earth
ground in category II installations.
Always be careful when working with voltage
above 60V DC or 30VAC RMS. Keep fingers
behind the probe barriers while measuring.
Inspect test leads and probes for cracks,
breaks or crazes on the insulation before
using the Meter.
Repair or maintenance should be
implemented by trained personnel.

7
Certification
CAT II: This meter has meet IEC1010-1
standard with an overvoltage category (CAT II)
and pollution2.
The Meter is compiled to EMC
requirements.
Introduction
Overview
The DAM190D is a portable pen-type digital multimeter
featuring 5V logic level test, DC/AC voltage and current
measurement, auto/manual range, maximum and hold
reading, auto power off, and LCD built in for easy reading.
The slim and lightweight design with retractable probe is
mobile and ideal for both professionals and hobbyists.

8
Figures and Components
Buttons and Components
1. Retractable Probe
2. Rotatable Probe knob
3. LED Indicator
4. Protective Ring
5. Rotary Switch
6. DATA-H (Hold) Button
7. RANGE Button
8. MAX.H (Hold) Button
9. FUNC. Button
10. Panel
11. LCD Display
12. COM Jack
Front Panel

9
Buttons and Components Description
RANGE Button
Choose auto or manual range
FUNC.F Button
Switch between AC/DC or between
resistance, continuity or diode
DATA-H Button
Data reading hold
Disable auto power off.
MAX.H Button
Measure and hold for maximum
reading
Rotary Switch
To select different functions
Probe
Input terminals for V/A/Ω/ /
and Logic
COM
Common terminal
Probe knob
Rotate the knob to retract probe
Protective Ring
Keep hand behind the ring for
safety

10
Display Description
AC
Alternating Current
DC
Direct Current
AC or DC
Diode
Buzzer
M.H
Maximum reading Hold
D.H
Data hold
AUTO
Auto range
Low battery indicator
Using the Meter
Preparation
Select a function and a range for the item to be
measured using the rotary switch and “RANGE”
button. In manual range, if the range to be
measured is unknown, start off with the highest
range.

11
In manual range, ‘OL’ is displayed when overload
occurs. Choose a higher range if possible to acquire
correct reading.
To perform measurement, first connect the test
lead to common (COM), then connect the probe tip
of the Meter to the circuit to be tested.
If the battery voltage is less than 2.4V, “ ”is
displayed, please change a new battery.
DC/AC Voltage Measurement
WARNING
USE CAUTION WHEN MEASUREING HIGH VOLTAGE
CIRCUITS TO AVOID ELECTRICAL SHOCK AND
INJURY. DO NOT TEST VOLTAGES HIGHER THAN
DC/AC 600V.
Rotate the probe knob clockwise to extend the
probe from the Meter.
Insert the black test lead or test clip in the “COM”
jack.
Set the rotary switch to the “V”position.
Press the "FUNC.F" button to switch between DC
and AC measurements. Manual range can be

12
chosen by pressing the “RANGE” button. Hold
“RANGE” to go back to Auto range.
Connect the probe tip of the Meter and tip of the
test lead (or test clip) across the power source or
load.
Read the measurement from LCD display. The
polarity of the Meter’s probe will be indicated.
NOTE:
In small voltage range, the Meter may show unsteady
reading when test leads are not connected to the circuit,
this is normal because of the sensitivity of the Meter.
When the Meter is connected to the circuit, true
readings will be displayed...
DC/AC Current Measurement
WARNING
USE CAUTION WHEN MEASUREING HIGH VOLTAGE
CIRCUITs TO AVOID ELECTRICAL SHOCK AND
INJURY. DO NOT TEST VOLTAGES HIGHER THAN
DC/AC 600V.
Rotate the probe knob clockwise to extend the
probe from the Meter.

13
Insert the black test lead or test clip in the “COM”
jack.
Set the rotary switch to the “mA ”position.
Press the "FUNC.F" button to switch between DC
and AC measurements. Manual range can be
chosen by pressing the “RANGE” button. Hold
“RANGE” to go back to Auto range.
Connect the probe tip of the Meter and tip of the
test lead (or test clip) across the power source or
load.
Read the measurement from LCD display. The
polarity of the Meter’s probe will be indicated.
Resistance Measurement
WARNING
TO AVOID ELECTRICAL SHOCK AND INJURY
POWER OFF THE CIRCUIT AND DISCHARGE THE
CAPACITANCE BEFORE MEASURING RESISTANCE.
Rotate the probe knob clockwise to extend the
probe from the Meter.
Insert the black test lead or test clip in the “COM”
jack.

14
Set the rotary switch to the “”position. Manual
range can be chosen by pressing the “RANGE”
button. Hold “RANGE” to go back to Auto range.
Connect the tip of the Meter probe and test lead
(or test clip) across the resistance or circuit under
measurement and read of the reading from LCD.
NOTE:
oThe Meter may take a few seconds to reach
steady reading if the measuring resistance is
above 1MΩ.
oWhen the input is not connected (i.e. an open
circuit) the figure ‘OL’ will be displayed.
Diode Test
Rotate the probe knob clockwise to extend the
probe from the Meter.
Insert the black test lead or test clip in the “COM”
jack.
Set the rotary switch to the “ ” position. Press
“FUNC.” to choose diode measurement; “ ” is
displayed.
Connect leads to the circuit terminals.
Read the measurement from the display.

15
NOTE:
The Meter shows the forward voltage drop. If the lead
connection is reversed, “OL” is displayed.
Continuity
WARNING
TO AVOID ELECTRICAL SHOCK AND INJURY
POWER OFF THE CIRCUIT AND DISCHARGE THE
CAPACITANCE BEFORE MEASURING CONTINUITY.
Rotate the probe knob clockwise to extend the
probe from the Meter.
Insert the black test lead or test clip in the “COM”
jack.
Set the rotary switch to the “ ” position. Press
“FUNC.” to choose continuity test; “ ” appears on
LCD.
Connect leads to the circuit terminals.
If continuity exists (i.e. resistance is less than 50),
built-in buzzer will sound.
If the result is an open circuit (or the circuit
resistance measured is higher than 200) “0L” is
displayed.

16
Logic Test
NOTE:
The logic test will only work for 5V Signals.
Make sure the retractable probe is stored back in the
Meter.
Insert the black test lead or test clip in the “COM”
jack.
Set the rotary switch to the “LOGIC” position.
Connect the black test clip to the GND(-) of the
circuits being measured.
Hold the “FUNC” button and touch the probe tip to
the circuit.Observe the logic state from LED
indicator; Red LED light expresses high level/logic
“1” and orange LED light expresses low level/logic
“0”. If the reading is between 1.5-3.5V, neither light
will be on.
You can also see ““ or “ “ on the LCD display;
““ expresses high level/logic “1” and
““expresses low level/logic “0”.

17
Data Hold
To hold the reading of a measurement, press
“DATAH” button once. “D.H” will appear on the
LCD, reading will be held. Press again to cancel
holding value.
Maximum and Hold
To show the maximum value of the measurement
and hold that value, press “MAX.H”button once.
“MAX.H”will appear on the LCD, reading will be
held. Press again to cancel holding maximum value.
Auto Off
When not in use, the Meter will automatically turn off
after 15 minutes. After auto off, press any button to
bring the power back on. The Meter will beep 5 times
1 minute before and a long beep right before it turns
off.
Hold “DATA.H” button followed by turning on the
Meter to disable auto off.

18
Specifications
General Specification
Auto and Manual Range.
Max. Voltage between Terminals and Earth Ground:
600V DC or AC
Maximum Operating Altitude: 7000 Ft (2000m).
Display: 0.79 In. (20mm) LCD
Maximum Number: 1999
Polarity Indication: ‘-’Indicates negative polarity.
Overload Indication: Display ‘OL’
Sampling Time: Approx. 0.4 second/time
Low Battery Indication: “ ”
Auto Power Off: 15 min.
Power Supply: 1.5V × 2 AAA battery
Operating Temperature: 32F To 104F(0℃To 40℃)
Storage Temperature: 10F To 122F(-10℃To 50℃)
Dimension: 8.2x1.5x1.14 in. (208×38×29mm)
Weight: Approx. 3.9oz (110g) including battery

19
Technical Specification
DC Voltage
Range
Resolution
Accuracy
200mV
0.1mV
2V
0.001V
20V
0.01V
± (0.7% + 2 counts)
200V
0.1V
600V
1V
Input Impedance: 10MΩ
Overload Protection:
o200mV range: 250V DC or AC rms
o2V to 600V ranges: DC 600V or AC 600V rms
Max. Input Voltage: 600V DC
AC Voltage
Range
Resolution
Accuracy
200mV
0.1mV
2V
0.001V
±(0.8% + 3 counts)
Table of contents
Other Dawson Tools Multimeter manuals

Dawson Tools
Dawson Tools DDM453 User manual

Dawson Tools
Dawson Tools DDM350 User manual

Dawson Tools
Dawson Tools DDM450 User manual

Dawson Tools
Dawson Tools DDM640 User manual

Dawson Tools
Dawson Tools DDM190 User manual

Dawson Tools
Dawson Tools DDM230C User manual

Dawson Tools
Dawson Tools DAN120 User manual