1. 8-pole DIN45326 connector, input for dissolved Oxygen and temperature combined probes
with SICRAM module, or temperature only Pt100 probes with SICRAM module.
2. 8-pole DIN45326 connector, for combined pH/mV/temperature electrodes with SICRAM
module, or temperature only Pt100 probes with SICRAM module.
3. Function key F1: The key’s function is described in the bottom line of the display. In standard
measurement mode, if you press it repeatedly, it toggles the unit of measurement of the
SICRAM pH probe connected to the left input, between pH, mV, or no indication.
4. Function key F2: The key’s function is described in the bottom line of the display. In standard
measurement mode, if you press it repeatedly, it toggles the unit of measurement of the
dissolved Oxygen probe connected to the central input, between Oxygen concentration in
liquids (mg/l), saturation index (%), or no indication in absence of the connected probe.
5. MEAS (measurement) key: It allows to repeat the measurement, when the EPT = AUTO, MAN
or TIME modes are selected (see the EPT function description on page 5). It also returns to
the standard display.
6. EPT (End PoinT) key: It selects the unit of measurement. The EPT, MAN, TIME, and AUTO
modes are available (see the EPT function description on page 5).
7. LOG key: It starts and ends the saving of data in the internal memory.
8. PRINT key: It prints the data on the current screen. It uses the serial communication port
RS232C, the USB 2.0 port, or, if any, the Bluetooth connection.
9. MEM key: It stores the currently displayed screen.
10. ESC key: In the menu, it cancels the operation in progress without making changes.
11. ENTER key: In the menu, it confirms the current selection.
12. key: In the menu, it moves the cursor leftwards. During measurement, it decreases the
display contrast.
13. HELP key: It shows a description of the instrument main functions on the display.
14. Power supply input 12Vdc for the ∅5.5mm - ∅2.1mm connector. Positive at centre.
15. 8-pole female MiniDin, serial RS232C and USB1.1-2.0 multiport connector.
16. MENU key: It allows access to the menu.
17. key: In the menu, it decreases the current value.
18. key: In the menu, it moves the cursor rightwards. During measurement, it increases the
display contrast.
19. DISP key: It gives the main parameters of the probes connected to the instrument, the
barometric pressure measured by the internal pressure sensor, the next memory positions
MEM and ID, current date and time.
20. key: In the menu, it increases the current value.
21. °C/°F key: If the temperature sensor is present, the key toggles the unit of measurement
between °C and °F. If no temperature or combined temperature probes are present, the key
allows manual input of the temperature value used for temperature compensation and
selection of the unit of measurement (°C or °F). See also the description of the ATC/MTC
feature.
22. CAL key: It starts the pH electrode, conductivity probe or dissolved Oxygen probe calibration
procedure.
23. ID key: It allows to set the sample identifier number.
24. ON-OFF key: It turns the instrument on and off.
25. Function key F3:The key’s function is described in the bottom line of the display. In standard
measurement mode, if you press it repeatedly, it toggles the unit of measurement of the
conductivity probe connected to the right input, between conductivity, resistivity, TDS, NaCl
concentration, or no indication.
26. Description of the F1, F2, F3 function keys:
27. Instrument display. The display is backlit: To enable or disable the backlight, select the menu
item Menu >> System Parameters >> Backlight. Use the arrows to modify the display
contrast.
28. 8-pole DIN45326 connector, input for combined 4-ring or 2-ring conductivity/temperature
probes complete with SICRAM module (the conductivity input is not compatible with the
temperature probes with SICRAM module).