DOP
-B03
High Color‧Wide Screen‧
User-Friendly HMI Products
No.18, Xinglong Rd., Taoyuan City
33068, Taiwan
B03S211 / B03E211 Instrunction Sheet
(1) Preface
Thank you for purchasing DELTA’s DOP-B series. This instruction sheet will be helpful in the installation, wiring and
inspection of Delta HMI. Before using the product, please read this instruction sheet to ensure correct use. You should
thoroughly understand all safety precautions before proceeding with the installation, wiring and operation. Place this
instruction sheet in a safe location for future reference. Please observe the following precautions:
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids.
Ensure that all wiring instructions and recommendations are followed.
Ensure that HMI is correctly connected to a ground. The grounding method must comply with the electrical
standard of the country (Please refer to NFPA 70: National Electrical Code, 2005 Ed.).
Do not disassemble HMI, modify or remove wiring when power is applied to HMI.
Do not touch the power supply during operation. Otherwise, it may cause electric shock.
If you have any questions during operation, please contact our local distributors or Delta sales representatives.
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the
most updated version at http://www.delta.com.tw/ia.
(2) Safety Precautions
Carefully note and observe the following safety precautions when receiving, inspecting, installing, operating, maintaining
and troubleshooting. The following words, DANGER, WARNING and STOP are used to mark safety precautions when
using the Delta’s HMI product. Failure to observe these precautions may void the warranty!
Installation
Comply with quick start for installation. Otherwise it may cause equipment damage.
Do not install the product in a location that is outside the stated specification for the HMI. Failure to
observe this caution may result in electric shock, fire, or explosion.
Do not install the product in a location where temperatures will exceed specification for the HMI.
Failure to observe this caution may result in abnormal operation or damage the product.
Please note that this equipment has obtained EMC registration for commercial use. In the event that it
has been mistakenly sold or purchased, please exchange it for equipment certified for home use.
Do not use this product as an alarm device for disaster early warning that may result in personal injury,
equipment damage, or system emergency stop.
Wiring
Connect the ground terminals to a class-3 ground (Ground resistance should not exceed 100Ω).
Improper grounding may result in communication error, electric shock or fire.
Operation
The users should use Delta Screen Editor software to perform editing in Delta's HMI product. To
perform editing and confirming HMI programs without using Delta Screen Editor software in Delta's
HMI product may result in abnormal operation.
To prevent the personal injury and equipment damage, when designing HMI programs, please ensure
that a communication error occurred between Delta’s HMI product and the connecting controller or
equipment will not result in system failure or malfunction.
Please be sure to backup the screen data and HMI programs in case they are lost, accidentally
deleted or worse.
Do not modify wiring during operation. Otherwise it may result in electric shock or personal injury.
Never use a hard or pointed object to hit or strike the screen as doing this may damage the screen and
let the screen has not respond at all, and then cause HMI to work abnormally.
Maintenance and Inspection
Do not touch any internal or exposed parts of the HMI as electrical shock may result.
Do not remove operation panel while power is on. Otherwise electrical shock may result.
Wait at least 10 minutes after power has been removed before touching any HMI terminals or
performing any wiring and/or inspection as an electrical charge may still remain in the HMI with
hazardous voltages even after power has been removed.
Turn the power off before changing backup battery and check system settings after finishing change.
(all data will be cleared after changing battery).
Be sure the ventilation holes are not obstructed during operation. Otherwise malfunction may result
due to bad ventilation or overheating troubles.
Wiring Method
Do not use a voltage that will exceed specification for the HMI. Failure to observe this caution may
result in electric shock or fire.
Remove the terminal block from the HMI before wiring.
Insert only one wire into one terminal on the terminal block.
If the wiring is in error, perform the wiring again with proper tools. Never use force to remove the
terminals or wires. Otherwise, it may result in malfunction or damage.
For the power line that forced to take out, ensure to check wiring again and restart.
Communication Wiring
Comply with communication wiring specification for wiring.
Wiring length should comply with the stated specification for the HMI.
Proper grounding to avoid bad communication quality.
To avoid noise and interference, the communication cable, all power cables, and motor power cable
should be placed in separate conduits.
(3) Pin Definition of Serial Communication
DOP-B03S211 / DOP-B03E211 COM1 and COM2 Ports
COM Port PIN
MODE1 MODE2 MODE3
COM1 COM2 COM1 COM2 COM1 COM2
RS-232 RS-485 RS-485 RS-485 RS-232 RS-422
1 D+ TXD+
2 RXD RXD
3 TXD TXD
4 D+ D+ RXD+
5 GND GND GND
6 D- TXD-
7 RTS
8 CTS
9 D- D- RXD-
Note1: Blank = No Connection.
(4) Parts Names
DOP-B03S211 / DOP-B03E211 (Front View)
A Touch Screen / Display
B Power LED Indicator ( ) Note: Lights in green when HMI works normally.
DOP-B03S211 (Rear View)
A System Key B USB Host C USB Slave
D Power Input Terminal E COM1
DOP-B03E211 (Rear View)
A Ethernet Interface (LAN) B System Key C USB Host
D USB Slave E Power Input Terminal F COM 1
(5) Dimensions
DOP-B03S211 / DOP-B03E211
129(5.08")
103(4.06")
+1.0
118.80(4.68" )
+1.0
92.80(3.65" )
T
29.5(1.16")
91(3.58")
Note:
T=1.6mm(0.063")~6mm(0.24")
+0.04"
0
+0.04"
0
(6) Specifications
MODEL DOP-B03S211 DOP-B03E211
LCD MODULE
Display Type 4.3" TFT LCD (65536 colors )
Resolution 480 x 272 pixels
Backlight LED Back Light (less than 20,000 hours half-life at 25oC) (Note 1)
Display Size 95.04 x 53.856mm
Operation System Delta Real Time OS
MCU 32-bit RISC Micro-controller
NOR Flash ROM Flash ROM 128 MB
(OS System: 30MB / Backup: 16MB / User Application: 82MB)
SDRAM 64Mbytes
Backup Memory 32Kbytes
Buzzer Multi-Tone Frequency (2K ~ 4K Hz) / 85dB
USB 1 USB Slave Ver 2.0
1 USB Host Ver 1.1
Serial
COM
Port
COM1 RS-232(supports hardware flow control) / RS-485
COM2 RS-422/RS-485
Ethernet Interface N/A 10M/100M
Perpetual Calendar Built-in
Cooling Method Natural air circulation
Safety Approval CE / UL (Note 3)
Waterproof Degree IP65 / NEMA4 (Note 3)
Operation Voltage
(Note2) DC +24V (-10% ~ +15%) (please use isolated power supply)
Voltage Endurance AC500V for 1 minute (between charging (DC24V terminal)
and FG terminals)
Power
Consumption (Note 2) 4.8W 7.2W
Backup Battery 3V lithium battery CR2032 x 1
Backup Battery Life It depends on the temperature used and the conditions of usage,
about 3 years or more at 25oC.
Operation
Temperature 0oC ~ 50oC
Storage
Temperature -20oC ~ +60oC
Ambient Humidity 10% ~ 90% RH [0 ~ 40oC], 10% ~ 55% RH [41 ~ 50oC], Pollution Degree 2
Vibration IEC 61131-2 compliant 5Hz≦f<8.3Hz = Continuous: 3.5mm, 8.3Hz≦f≦150Hz = Continuous:
1.0g
Shock IEC 60068-2-27 compliant 15g peak for 11 ms duration, X, Y, Z directions for 6 times
Dimensions
(W) x (H) x (D) mm 129 x103 x 39
Panel Cutout
(W) x (H) mm 118.8 x 92.8
Weight Approx. 230g Approx. 264g
NOTE
1) The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving current is supplied
to HMI. The life of LED backlight shown here is an estimated value under 25oC normal temperature and humidity conditions.
2) The value of the power consumption indicates the electrical power consumed by HMI only without connecting to any
peripheral devices. In order to ensure the normal operation, it is recommended to use a power supply which the capacity is 1.5
~2 times the value of the power consumption.
3) Some models are in the process of application to certification. For more information, please consult our distributors.
4) The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the most
updated version at http://www.delta.com.tw/ia/.
PIN1
A
B
A
E
C
D
B
A
B
C
D
E
F