parallel. In this case, provide 10-40mm gaps between the units.
2.4 Do not install the unit in a location where it will be exposed to water, excessive steam, dust /
explosive gas or corrosive gas.
2.5 Always disconnect, lock and tag power source before installing or servicing. Failure to
disconnect power source can result in fire, shock or serious injury.
2.6 Please ensure the unit is installed in a firm place otherwise operating the unit may cause the
wall or ceiling to become loose, shake and/or make noise.
2.7 Verify and ensure the rated voltage and frequency (please refer to the rating label) of the air
curtain is in compliance with the mains supply.
2.8 Do not cover the air inlet or air outlet of the air curtain when it is in operation.
2.9 Routine maintenance must be carried out annually.
2.10 Never use petrol, benzene, thinner or any other such chemical for cleaning the unit.
2.11 When connecting the power cord to the power supply, please make sure the distance
between contacts is at least 3mm.
2.12 Installation work and electrical wiring must be done by qualified person(s) in accordance
with all applicable codes and standards, including fire-rated construction.
2.13 When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other
hidden utilities.
2.14 To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed
control device
2.15 Repair and maintenance operations can only be performed by qualified personnel.
2.16 This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
2.17 Children should be supervised to ensure that they do not play with the appliance.
3. TECHNICAL PARAMETER
Model
No.
Voltage (V~Hz)
power(W)
L/H (KW)
(m3/h)
(m/s)
level(dB)
DVSH40WH 230~50 75 2.0/4.0 430 5 49