UI-\I'BT
V I Jl\71 Function Setting :
Put the Cal JP "OFF" position ( Short jumper off ) :
1. Press ( T I 1.5 seconds, the display show " OFF x x "' mean is auto power off
function : 3 minute - 30 minute and 0 (always ON) . Press( I I to choose 3,10,15
and 30, for automatically power off .
2.Press( M Ithedisplayshow:"bp On"or" bp OFF",Press ( I I
to choose 0n or OFF torbuzzer sound or not sound.
3.Press t M I thedisplayshow:"1 xx.x", Press(+I ( t I,toselect I
a new value for weight uhder the limit ( L0 )
4,press t M lthedisplayshow"0 xx.x".Press( +)( I ),toselecta
new value for weight between the Hl & LO limit ( OK ).
5.press ( M Ithedisptayshow uH XX.X;.Press(+ If I l,toselect
a new value for weight over the limit ( Hl ).
6.Press ( N4 ) thedisplayshow " 08.09.10 ".Meanisyear/month/day.
0B=year,09=month,10=day.Press ( + ) ( I I ,toselectthevalue.
7. Press ( M I the display show " 12.34.56 ". Mean is hour / minute / second.
,12= hours, 34 = minutes, 56 =second. Press( +I ( I I,toselectthevalue.
B. Press ( M I return to normal display weight.
Error Messages :
Display Possible Cause Solution
Press "POWER" no
display.
The 230ViAC power supplY not
working or Re-chargeable
batterv no voltaqe.
Check the power supply or
battery and power switch.
One section of LED
disolav no liqht
The LED display is not good in
condition
To replace LED display
The display reading
not stable To check the platform structure To open the platform
structure and clean the
structure
The scale can not do
calibration.
To check the calibration jumper
( put to '0N' position )To open casing and place the
Cal iumoer 0N position
The scale is not
accurate
The Load Cell is not good tn
condition
To reolace the new Load Cell
. INDICATOR Dt-28SS