Digi Connectware Series User manual

91000926_B
RJ-45 to DB-25 Straight-Through Cable Legs
Digi has available two lengths of RJ-45 to DB-25 straight-through (DTE)
cable legs.
Additional Cabling Information
For additional cabling information, consult the Digi International web
site at www.digi.com.
Diagnostics and Loopback Plugs
To verify that the ClassicBoard EIA-232 adapter and ports are functional,
use the appropriate DB-25 or RJ-45 loopback plug with the ClassicBoard
EIA-232 PCI diagnostic program. Loopback plugs are typically shipped
with the product. The PCI diagnostic program and instructions can be
found on the diagnostic diskette included with the adapter.
What Next?
After installing the hardware, you must install the software driver for
your operating system. Refer to the appropriate ClassicBoard PCI driver
installation instructions that came with your adapter.
Specifications
Power Requirements
Environmental Requirements
Regulatory Notices
Radio Frequency Interference (FCC 15.105)
This device has been tested and found to comply with the limits for Class B digital devices pursuant to Part 15 Subpart
B, of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi-
dential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Labeling Requirements (FCC 15.19)
This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Modifications (FCC 15.21)
Changes or modifications to this equipment not expressly approved by Digi may void the user’s authority to operate
this equipment.
Cables (FCC 15.27)
Shielded cables must be used to remain within the Class B limitations.
Declaration Of Conformity
(In accordance with FCC Dockets 96-208 and 95-19)
Manufacturer’s Name: Digi International
Digi International declares, that the product:
to which this declaration relates, meets the requirements specified by the Federal Communications Commission as
detailed in the following specifications:
Part 15, Subpart B, for Class B Equipment
FCC Docket 96-208 as it applies to class B
personal Computers and Peripherals
The product listed above has been tested at an External Test Laboratory certified per FCC rules and has been found to
meet the FCC, Part 15, Class B, Emission Limits. Documentation is on file and available from the Digi International
Homologation Department.
The ClassicBoard PCI 4 and ClassicBoard PCI 8 adapters are certified to meet the following emissions, safety and
immunity standards:
Copyright
© Digi International Inc., 1998, 1999, 2000, 2001, 2002, 2003
The Digi logo and ClassicBoard are registered trademarks of Digi International. All other brand and product names are
trademarks of their respective holders.
All Rights Reserved.
ClassicBoard
4 and 8 Port
PCI Host Adapter
EIA-232
EIA-422
Hardware Installation
and Cable Guide
Introduction
The ClassicBoard PCI adapters easily expand the number of EIA-232 or
EIA-422 ports available on a computer, allowing you to directly add
additional peripheral devices such as point-of-sale peripherals, terminals
or serial printers.
Resources
The hardware resources for the ClassicBoard PCI adapter are dynami-
cally assigned by the operating system each time the system boots.
Installing the ClassicBoard Adapter
Before Installing the Adapter
•Be sure that you have the correct cables for the interface used with
the ClassicBoard.
•Record the adapter serial number (located under the part number
label). This will enable Digi to provide you with better service,
should the need arise.
•Unplug power from the computer.
•Put a ground strap on to ground yourself. If one is not available,
ground yourself by touching an unpainted metal surface, such as the
computer chassis.
Installation Procedure
1. Remove the computer cover.
2. Locate an available PCI slot in your computer and remove the slot
plate.
3. Insert the board into the slot and screw the endplate to the computer
chassis. The endplate must be screwed into the computer chassis to
remain in compliance with Part 15 of FCC rules.
4. Replace the computer cover.
5. Connect the 78-pin connector assembly to the adapter.
Connector Type 24 inches 48 inches
DB-25 Male DTE 76000129 76000195
ClassicBoard 4 and 8 EIA-232 and EIA-422
350mA typical +5V 40mA typical +12V 40mA typical –12V
Temperature Relative Humidity
10°to 55°C (50°to 131°F) 5% to 90%, non-condensing
Altitude Air Movement
0 to 3,600 m (0 to 12,000 ft.) 30 CFM forced
Corporate
Headquarters: 11001 Bren Road East
Minnetonka MN 55343
Manufacturing
Headquarters: 10000 West 76th Street,
Eden Prairie MN 55344
Product Name: Digi ClassicBoard PCI 4 Digi ClassicBoard PCI 8
Model Numbers: 50001136-02
50001136-04
50001136-06
50001136-01
50001136-03
50001136-05
•FCC Part 15, Subpart B, for Class B Equipment •CSA C22.2 No. 950
•EN 55022 Class B •EN 60950
•VCCI Class II •EN 50082-2
•ICES-003 Class B •AS3260
•UL 1950 •AS3548

Digi Connector Options
There are three different connector assembly options available to use
with a ClassicBoard adapter; an RJ-45 Connector Box, a DB-25 Connec-
tor Box, and a DB-25 Cable Assembly.
Example: ClassicBoard 4 Adapter and Connector Assemblies
DB-25 Connectors
DB-25 connectors are available in two styles; a quad or octa cable assem-
bly, or a quad or octa connector box assembly. Either style is available
with male or female connectors and as DTE or DCE cables
DB-25 Connector Cables and Part Numbers
DB-25 Connector Cable Part Numbers
DB-25 Connector Boxes and Part Numbers
RJ-45 Connectors
The RJ-45 Connector Boxes are only available as straight-through
(DTE).
RJ-45 Connector Options and Part Numbers
Peripheral Cabling
The ClassicBoard PCI adapter can connect to point-of-sale peripherals,
terminals, serial printers or any other standard EIA-232 device can be
connected to a ClassicBoard PCI adapter. These devices can be located
some distance from the adapter. It is important that cables be properly
constructed. To achieve the greatest reliability over distance, cables
should be:
•Shielded, low capacitance, and preferably designed specifically
for serial data transmission.
•Grounded at both ends of the cable.
•Routed away from noise sources such as generators, motors and
fluorescent lights.
Pinouts
Pin Numbers and EIA-232 Signals
When making RJ-45 cables, it is important to know that pin 1 is on the
left side of the connector as you hold the cable upright (as shown in the
figure), with the clip facing away from you.
To avoid cabling problems with terminals and printers, Digi recommends
that you use cables with the pinouts described in the following table.
Note:For Okidata printers, you may need to wire CTS from the Classic-
Board connector to pin 11 (SSD) on the printer side.
Recommended Printer/Terminal Cable
* RTS and CTS are tied together on the Terminal/Printer connector.
Recommended Straight-through Cable
Pin Numbers and EIA-422 Signals
Connector Type
for EIA-232 DTE
4-Port DCE
4-Port DTE
8-Port DCE
8-Port
DB-25 Male 76000008 76000007 76000021 76000020
DB-25 Female 76000006 76000005 76000019 76000018
Connector Type for EIA-422 4-Port 8-Port
DB-25 Male 76000178 76000179
Connector Type
for EIA-232 DTE
4-Port DCE
4-Port DTE
8-Port DCE
8-Port
DB-25 Male 76000030 N/A 76000031 76000029
DB-25 Female 76000026 76000024 76000027 76000025
EIA-232
only
Connector Type for EIA-232 4-Port 8-Port
RJ-45 76000038 76000033
RJ-11 RJ-45 EIA-232
Signal DB-25
4 Pin 6 Pin 8 Pin 10 Pin
N/A N/A N/A 1RI 22
N/A N/A 1 2 DSR 6
N/A 1 2 3 RTS 4
1 2 3 4 GND* 1
2 3 4 5 TxD 2
3 4 5 6 RxD 3
4 5 6 7 SG** 7
N/A 6 7 8 CTS 5
N/A N/A 8 9 DTR 20
N/A N/A N/A 10 DCD 8
* Frame Ground ** Signal Ground
Pin 1 Pin x
AR0054
ClassicBoard Connector Tie these signals/
pins together Terminal/Printer
RJ45 8-pin DB-25 DB-25
31GNDtoGND 1
4 2 TxD to RxD 3
5 3 RxD to TxD 2
6 7 SG to SG 7
75CTStoDTR 20
RTS/CTS 4 to 5*
ClassicBoard EIA-232
Signal Device
RJ-45 8-pin RJ-45 10-pin DB-25 DB-25
Not Available 1 22 RI 22
126DSR6
234RTS4
341GND1
4 5 2 TxD 2
5 6 3 RxD 3
677SG7
785CTS5
8920DTR20
Not Available 10 8 DCD 8
Signal DB-25 Pin Description
TxD+ 2Transmit Data High
RxD+ 3Receive Data High
RTS+ 4Request to Send High
CTS+ 5Clear to Send High
CTS- 13 Clear to Send Low
TxD- 14 Transmit Data Low
RxD- 16 Receive Data Low
RTS- 19 Request to Send Low
EIA-232 or
EIA-422
EIA-232
only
This manual suits for next models
2
Other Digi Adapter manuals

Digi
Digi Edgeport/E User manual

Digi
Digi Xbee3 XU3-A11 User manual

Digi
Digi WVA User manual

Digi
Digi Connectware AccelePort Xp 2p User manual

Digi
Digi XBee 3 User manual

Digi
Digi AccelePort Xr 920 Series Manual

Digi
Digi Wavespeed S User manual

Digi
Digi One IAP User manual

Digi
Digi AccelePort Xem Manual

Digi
Digi XBee3 DigiMesh 2.4 User manual