Translation of the original instructions
1 Applicable documents
All available documents for the product èwww.festo.com/pk.
2 Safety
2.1 Safety instructions
– Do not connect or disconnect plug connector when powered.
– Only assemble the product on components that are in a condition to be safely
operated.
2.2 Intended use
Adapter cable for the IO-Link connection via the interface [X1] of the integrated
drives EMCS.
3 Configuration
3.1 Product design
1Socket M12x1, A-coded
2Plug M12x1, A-coded
3Cable
Fig. 1
3.2 Contact assignment
Electrical connection1
Field device side
Electrical connection2
Controller side
1Socket Pin Pin 2Plug con-
nector
1 1
2 2
3 4
4 3
5…8 not assigned 5 not assigned
Tab. 1 Contact assignment
4 Mounting
4.1 Mounting of electrical connection 1
1. Align socket1 to match plug.
2. Connect socket1 to the plug.
3. Tighten the screw-type lock of the socket1. Tightening torque:
0.4Nm±55%
4.2 Mounting of electrical connection 2
1. Align the plug2 to match the socket.
2. Insert the plug2 into the socket.
3. Tighten the screw-type lock of the plug2. Tightening torque: 0.4Nm±55%
4.3 Wiring
Feature Cable characteristic Wiring
-E- Suitable for energy chains In energy chain or flexible
Tab. 2 Wiring
4.4 Mounting in energy chain
1. Lay the chain out lengthwise.
2. Place the cables in the chain, making sure they are not twisted.
3. Separate cables from each other using separators/drill holes.
4. Do not connect cables together.
Fig. 2
5. Maintain spaceX. X>10% of the cable diameterD.
If the chain is suspended vertically: increase the spaceX.
Fig. 3
6. Align chain in the operating position:
– Make sure that the radius is greater than the bending radius R of the
cables.
– Cables can move freely in the bending radiusKR of the energy chain.
ÄCables are not forced through the chain.
7. Mount the energy chain ècorresponding instructions.
8. Fasten cables:
– At both ends of the chain in case of short energy chains
– Only at the driver end in the case of long, sliding energy chains
Fig. 4
9. Do not bend cables all the way to the fastening point.
ÄMounting spaceA between the fastening point and bending movement is
observed.
NOTICE!
Damage to cables if the chain breaks.
• Replace cables after a chain break.
NOTICE!
Malfunction and material damage due to vertically suspended cables.
The cables stretch.
• Regularly check the length of the cables.
• Readjust the cables if required.
5 Technical data
NEFC-M12G8-M12G5-LK
Cable characteristic Suitable for energy chains
Cable composition [mm²] 5x0.34
Shielding No
Cable diameter D [mm] 5.1
Mounting space A [mm] ³102
Current rating at 40°C [A] 2
Surge resistance [kV] 0.8
Operating voltage range
AC UB[V] 0…48
DC UB[V] 0…60
Bending radius
Fixed cable installation R [mm] ³26
Flexible cable installation R [mm] ³26
8109804
NEFC-M12G8-M12G5-LK
Adapter
8109804
2019-04
[8109806]
Instructions| Assembly