Dinghua DH-B1 BGA User manual

1
DH-B1 BGARework Station Manual
ADD:3rd floor, 46th building, Da Yangtian Industry District, Shajing Town,
Bao‟an District, Shenzhen, China
Website:www.sinobga.com
Tel.:86-755-29091633 29091833
Fax:86-55-29091622
E-mail:dh-smt@hotmail.com

2
一、Company profile
Shenzhen Dinghua Technology & Development Co., Ltd is a professional manufacturer of
BGA rework station, rework tools and associated equipments, engaging in design, production,
sales and service.We commit us to make the professional equipment, provide the high quality a
perfect service for the customer. As one of pioneer in this industry, we continue to improve and
innovate along with the market demands by absorbing the advanced development experience from
home and abroad to adhering to our vision of „Professionalism, Honesty, Innovative and
Responsibility‟.
Science and technology are primary productive forces. Through teamwork, we achieved the
core thermal-control technology with related patent. At the same time, our products cover 3
categories: high-end, mid-end and low-end for development and production using manual,
semi-auto to fully automated processes. Our market had expanded into industries like: individual
repair, factories, education, military and aerospace etc. And we had established the point-of sales
and end service at locally and abroad.
Your satisfaction is our target, adhering to customer-focus, market oriented, and our company
provides fist class products and high efficient services for customers through continuous
innovation. We are honored to work with you to create a brighter future.
二Installation of BGA rework station
(一)Installation sites
In order to ensure that the useful life of BGA rework station, installation of repair station must
meet the following conditions:
1、Awayfromflammableandexplosivematerials
2、Do not splash water or other liquids
3、Well-ventilated,dryplace
4、Stable , flat areas less susceptible to vibration
5、Place lessdust
6、Prohibit Placing heavy objects on top of the control box
7、Without the affect of air-conditioners,heaters and fans
8、Reserved for 30cm to move and rotate around the upper for the back of rework station
(二)Power Requirements
Voltage fluctuations: 220V±10
Frequency fluctuations: 50Hz±3

3
三、Safety Precautions of rework station
1、Do not use fans or other devices directly to the repair station hair when it works, otherwise it
will lead to negative differential heating plate surface , burn the workpiece.
2、When turned on, high-temperature heating zone can not be any direct contact with the object , it
may cause fire or explosion ,and the PCB workpiece should be placed on the PCB support
shelves.
3、Do not shake rework station , and move gently
4、Do not touch the high fever area , otherwise it will burn
5、When turned on, do not use the flammable spray , liquid or flammable gas near the repair
station.
6、Do not try to modify rework station , otherwise it will cause fire or electric shock.
7、Electrical box has the high-voltage components , do not attempt to disassemble
8、If the metal objects or liquids fall into the repair station when it works , immediately disconnect
the power , unplug the power cord until the machine to cool down , then completely remove
litter , dirt ; if dirt left ,there is odor when reboot.
9、When abnormal heating or smoking,immediately disconnect the power , and inform the
technical service to repair.It needs to disconnect the wires between the electrical boxes and
machine parts,and have to hold the plug,otherwise it leads to poor contact ,and does not work.
10、Note that the repair station not to press or run over other electrical equipment or power lines or
communication cable , and it may cause device malfunction or cause fire or electric shock.
11 、Before use the rework station, you must read this manual carefully

4
四 、Structures and specifications
(一)Structures
(二)Features
Number
Name
Functions
Use ways
1
Limit bar
limit the lowest position of the
upper heating
Rotate to the right place
2
Tension adjustment knob
lock the upper heating of up and
down , forward and back
Rotate the knob
3
Forward and back adjustment
handle
Adjust the upper heating of
Forward and back position
Rotating the handle
4
Up and down adjustment
handle
Adjust the upper heating of up
and down position
Rotating the handle
5
7 handle
lock the rotation angle of the
upper heating
Rotating the handle
6
LED head light
Lighting equipment at work
Press the button
7
Top nozzle
To focus the hot air
Pull air from the BGAsuitable
location
8
Bottom nozzle
To focus the hot air
Pull air from the BGAsuitable

5
location
9
Switch
Turn on and off the machine
Push the switch
10
Bottom heater up and down
handle
Adjust the lower nozzle
distance from the PCB board
Rotating the handle
11
Vacuum pen
Remove the chips
Click vacuum on the touch screen
12
Emergency stop button
Emergency stop
Press the button
13
head light button
light switch
Press the button
14
Touch screen
Data storage system platform
15
USB interface
External USB drive
16
Temperature sensor
Connect an external galvanic ,
measure the actual temperature
Directly connect temperature line
17
IR preheating zone
BGA rework with warm-up
18
PCB support
Move the right position ,
clamping the PCB
19
Universal fixture
Adjust the PCB in any direction
20
Powerful cross fan
Cooling the PCB board
after welding
Click cooling on the touch screen
(三)Specification:
Total Power
4800W
Top heater
800W
Bottom heater
Second heater 1200W, IR preheating
2700W
power
AC220V±10%50Hz
Dimensions
500x600x700mm
Positioning
V-groove, PCB support can be adjusted
in any direction with external universal
fixture
Temperature control
K Sensor,Closed loop
Temp accuracy
± 2 ℃
PCB size
Max 500×400 mm Min 22×22 mm
BGA chip
2X2-80X80mm
Minimum chip spacing
0.15mm
External Temperature Sensor
1(optional)
Net weight
45kg
Table of contents