User Responsibility ........................3
Standard and Optional Features..............4
Receiving , Assembly and Instructions ........5
Assembled View ...........................9
Optional accessories Assembly Instructions ..10
Assembled View With Optional Accessories...13
Moduflex NRB with 3 patients circuits .......14
Warranty ................................15
Order Part Numbers ......................16

805-0975-800 3
Read this manual before operating the unit. Pay special attention to
all warnings and cautions.
• This product will perform in conformity with the description
contained in this operating manual when assembled, operated,
maintained and repaired in accordance with the instructions
provided.
• This product must be verified periodically.
• A defective product should not be used.
• Parts that are broken, missing, plainly worn, distorted or
contaminated should be replaced immediately.
• Should a repair or replacement become necessary, Dispomed
recommends that a request be placed by phone or in writing to the
nearest Dispomed regional service center.
• This product, or any of its parts, should not be repaired other than
in accordance with written instructions provided by Dispomed and
by Dispomed trained personnel.
• The product may not be altered without prior written approval
from Dispomed.
• The user of this product shall have the sole responsibility for any
malfunction which results from improper use, faulty maintenance,
improper repair, damage or alteration by anyone other than a
Dispomed trained technician.
USER
RESPONSIBILITY

805-0975-800
4
STANDARD FEATURES
• 0.1 to 4 LPM O2flowmeter.
• Rotary float and large scale for easy readability.
• Recessed flush valve to prevent accidental activation.
• Quick connect fresh gas outlet for easy and secure switching between breathing
circuits.
• SELECTATECTM compatibility manifold for easy and quick installation of vaporizer.
• Five caster spider base.
• 2.5 meter oxygen supply hose (D.I.S.S.).
• 1 meter (3,28’) of fresh gas tubing.
• Fresh gas connector.
• 5 year warranty.
OPTIONAL FEATURES
• Small cylinder holder
• Bain circuit adaptor
• Circuit pressure alarm
• wallmount unit
• MRI compatible
• Up to 3 patients circuits
THE NRB
ANESTHESIA MACHINE
De façon à répondre aux besoins des vétérinaires travaillant avec les petits animaux, ou aux
centres de recherche avec des petits rongeurs ou encore ceux qui utilisent un circuit ouvert
(Bain), Dispomed a développé le Moduflex Compact NRB.

805-0975-800 5
Your Moduflex NRB anesthesia machine
requires some assembly before use.
RECEIVING
In order to reduce the possibility of damage
to a minimum during shipping, certain
components have been detached from
the unit. These components are packed
separately within the shipping crate.
INSPECTION
On receipt of your unit, inspect the shipping
container and the enclosed components for
signs of damage. Check your Materials List to
ensure that all the necessary components are
included.
RECEIVING AND ASSEMBLY
INSTRUCTIONS
x1
x1
x1
x1
x1 x1
x1
x1
x1
x1
x1

805-0975-800
6
1
RECEIVING, ASSEMBLY
INSTRUCTIONS CONTINUED
Remove the spider base from the box and
slide the tapered end of the black post onto
it.
2
Remove the accessories from the bag.

805-0975-800 7
RECEIVING, ASSEMBLY
INSTRUCTIONS CONTINUED
3
Remove the head assembly from the inner
box and insert into the top of the post (there
is a large hole under the head assembly
manifold) and tighten the head assembly by
securing the screw onto the post using the
key supplied.
Install the oxygen supply hose to the rear of
the machine.
84

805-0975-800
8
RECEIVING, ASSEMBLY
INSTRUCTIONS CONTINUED
Connect the other end of the oxygen tube to
50 p.s.i. (3 bars) oxygen supply.
5

805-0975-800 9
ASSEMBLED
VIEWS
Flowmeter
Black Post
Flush valve
Spider Base

805-0975-800
10
Mount the vaporizer on the unit as
illustrated. Once mounted lock it in place
with the vaporizer locking mechanism.
OPTIONAL ACCESSORIES
ASSEMBLY INSTRUCTIONS
VAPORIZER SCAVENGER INTERFACE
Install the scavenger interface as per
interface instructions.
During surgery the unused gas should be evacuated
outside of the building to avoid it being inhaled
by your employees and patients. Connected to a
gas evacuation ventilator, the scavenger interface
controls the flow of suction and maintains the
balance with the quantity of unused gas.
IMPORTANT : Always refer to the user manual of the option you are installing for more detailed instructions.

805-0975-800 11
Install Bain circuit adaptor as illustrated.
A Bain type open circuit on an anesthesia machine
gives you better control during surgery. The
breathing bag is always inflated, no need to
wait for it to have reached a certain size before
ventilating the patient.
OPTIONAL ACCESSORIES
ASSEMBLY INSTRUCTIONS
IMPORTANT : Always refer to the user manual of the option you are installing for more detailed instructions.
MODUFLEX BAIN E-CYLINDER HOLDER
Installation of dual cylinder holder.
The cylinder holder can be helpful in many
situations. It can be very useful when there is a lack
of oxygen in the central system. In the occasional
case where you need to move an anesthetized
animal to a room where there are no oxygen
outlets, the cylinder holder enables you to keep the
patient in an ideal condition.
CYLINDER HOLDER

805-0975-800
12
OPTIONAL ACCESSORIES
ASSEMBLY INSTRUCTIONS
IMPORTANT : Always refer to the user manual of the option you are installing for more detailed instructions.
Install wallmount adaptor as illustrated.
WALL-MOUNT

805-0975-800 13
ASSEMBLED VIEW
WITH OPTIONAL ACCESSORIES

805-0975-800
14
MODUFLEX NRB
WITH 3 PATIENTS CIRCUITS
Primary Output
Caution:when equipped with 3 fresh
gas outlet, the bottom one must always be
used, the 2 upper ones have check valves
incorporated to prevent flow when not in
use.

805-0975-800 15
DISPOMED
WARRANTY
Dispomed Ltd. guarantees that the Moduflex
Compact anesthesia machine is free from
manufacturing defects for a period of five
(5) years from the date of delivery to the
customer, provided that it is used according
to the instructions provided and that the
prescribed maintenance and service are
performed.
Dispomed shall not be held liable for
damage, injury or loss arising out of the
use of the product, whether as a result of a
defect in the product or otherwise, if, prior
to such damage, injury or loss, the product
was:
1. Damaged, misused or misapplied;
2. Repaired, altered or modified by a
person other than a Dispomed Ltd.
technician or approved service person;
3. Not installed in strict compliance with
the instructions provided by Dispomed
or with the applicable codes and
ordinances in place;
4. Cleaned using alcohol or other
damaging products.
Plastic, rubber and consumable items are
guaranteed to be free of defects at the date
of delivery to the customer.
Any product which proves to be defective in
workmanship or material will, at Dispomed’s
discretion, either be repaired or replaced.
Dispomed Ltd. is not responsible for
deterioration, wear or abuse of this unit.
This warranty shall be void for any product
on which the serial number has been
altered, defaced or removed.
Shipping charges for any unit repaired
or replaced are the responsibility of the
customer. Loaner units are available while
your unit is being repaired.
SERVICE AND INFORMATION
CENTER
Contact us at:
T: 1-800-363-1746
T: 1 450 759-9395
F: 1 450 759-8181
Email: [email protected]
Website: www.dispomed.com
blog: www.veterinary-equipment.net
Facebook: www.facebook.com/dispomed
Twitter: twitter.com/Dispomed
Youtube: www.youtube.com/dispomedltd

805-0975-800
16
REPLACEMENT
PART NUMBERS
Flowmeter shield
930-0100-110
Flowmeter valve
930-0105-000
Preassembled flush cartridge
975-0300-275
Quick connect
850-LC10004
845-S010 x2
845-S106 x2
845-S113 x2
845-S114 x2
Fresh gas elbow
850-0030-000

805-0975-800 17
REPLACEMENT
PART NUMBERS
Fresh gas elbow
850-0030-000
Quick Connect
850-LC10004

Manufactured by Dispomed ltd
745 Nazaire-Laurin Joliette (QC) Canada J6E 0L6
T : 1-800-363-1746 (Canada and U.S.A only)
T : 1-450-759-9395
Fax : 1-450-759-8181
www.dispomed.com
PRINTED IN CANADA
Table of contents
Other dispomed Medical Equipment manuals
Popular Medical Equipment manuals by other brands

SENSIRION
SENSIRION Winnipeg Ventilator Quick reference guide

Dräger
Dräger Infinity Acute Care System Evita Infinity... Pocket guide

Atmos
Atmos E 201 Thorax operating instructions

LINET
LINET Virtuoso User manual and technical description

Orliman
Orliman MANUTEC MFP-D91 INSTRUCTIONS FOR USE AND PRESERVATION

NDS
NDS ZeroWire Mobile user manual