15
TROUBLESHOOTING GUIDE (cont’d)
REPLACING THE FLUSH BALL SEAL AND
BOWL SEAL
1. Turnoffwaterandelectricalpowertotoilet.
2. Removewaterinlethosefromtoilet.
3. Removetoiletfromoorandturnitupside
down.
4. Removethreenutsandatwasherssecuring
baseassemblytotoiletbowlusinga1/4-inch
driveratchetwrench,7/16-inchdeep-well
socketandextension.
5. Pullcheckvalveoutofthesealinggrommet
locatedinrearoftoiletbowl.
6. Liftbaseassemblyfromtoilet.
7. Replaceoldsealswithacompletesealkit.
8. Reconnectbaseassemblytotoiletwithnew
mountingbolts(L-shaped)includedwithseal
kit.Tightennutsto20-25in.-lbs.torque.
9. Reattachwaterinlethosetotoilet
10.Reinstalltoilettooor.
REPLACING THE FLUSH BALL
1. Turnoffwatertotoilet.
2. Openushballbyinitiatingaushcycleand
immediatelyturningoffpowertopreventush
ballfromclosing.
3. Disconnectwaterinlethose.
4. Removetoiletfromoorandturnupsidedown.
5. Pullcheckvalveoutofsealinggrommetlo-
catedinrearoftoiletbowl.
6. Removethreenutsandatwasherssecuring
baseassemblytoceramictoiletbowlusinga
1/4-inchdriveratchetwrench,7/16-inchdeep-
wellsocketandextension.
7. Liftbaseassemblyfromtoilet.
8. Removebowlseal,ushballseal,andretainer
platetoexposeushball.
9. Loosensetscrewintherotorshaftcamusing
a1/8-inchhextool.
10.Removethe#8x1/4-inchlongscrewandat
washerfromlinkageslot.
11.Removethefourscrewssecuringthemounting
brackettobase.
12.Pullmountingbracketandrotorcamoffbase.
13.Rotateushballforwardandremoveushball
retainingscrew.
14.Replaceushballandreversedisassembly
procedure.
15.Pushrotorcamallthewayontorotorshaft.
Tightensetscrew.
16.Lubricatemovingpartswithsiliconegrease.
17.Beforemountingbasetotoilet,thecamswitch
mayrequireadjustment.See“AdjustingThe
CamSwitch”onpage14.
REPLACING THE ROTOR SHAFT
1. Followdisassemblysteps1through14under
“ReplacingtheFlushBall”.
2. Pullrotorshaftoutfrominsideofthebase.
3. LubricateO-ringsonnewshaftwithsilicone
grease.
4. Alignatsectiononrotorshaftwithatsec-
tionincamduringassembly.Pushrotorshaft
camfullyontorotorshaft.Tightensetscrew.
5. Lubricatemovingpartswithsiliconegrease.
6. Reversethedisassemblyprocedure.
7. Beforeattachingbasetotoilet,thecam
switchmayrequireadjustment.See
“AdjustingTheCamSwitch”onpage14.
REPLACING THE ROTOR SHAFT CAM
1. Followdisassemblysteps1through14under
“ReplacingtheFlushBall”.
2. Removelinkagepinclipandpin.
3. Attachnewrotorshaftcamtolinkageusing
pinandclip.
4. Lubricatemovingpartswithsiliconegrease.
5. Reversethedisassemblyprocedure.
6. Beforeattachingbasetotoilet,thecam
switchmayrequireadjustment.See
“AdjustingTheCamSwitch”onpage14.
REPLACING THE MOTOR DRIVE ARM
1. Followdisassemblysteps1through11under
“ReplacingtheFlushBall”.
2. Removethefourmotormountingscrews.
3. Removethemotorfromthemountingbracket.
4. LoosentheDriveArmsetscrewusinga3/32-
inchhextool,thenremoveoldDriveArm.
5. InstallnewDriveArmandpushontomotor
shaftasfaraspossible.Tightenthesetscrew.
6. Reversedisassemblyprocedure.
7. Lubricatemovingpartswithsiliconegrease.
8. Beforeattachingbasetotoilet,thecam
switchmayrequireadjustment.See
“AdjustingTheCamSwitch”onpage14.
REPLACING THE DRIVE LINKAGE
1. Followdisassemblysteps1through13under
“ReplacingTheFlushBall”.
2. Removelinkagepinclipandpinatrotorshaft
cam.
3. Removetheushspringretainingscrewand
washerfromtheretainingpost.
4. Removetheushspringfromtheoldlinkage.
5. Inserttheushspringintothenewlinkage
andreattachthespringtotheretainingpost.
6. Attachlinkagetorotorshaftcamusingpin
andclip.
7. Lubricatemovingpartswithsiliconegrease.
8. Reversethedisassemblyprocedure.