Door-Gard 232i Operating instructions

FEATURES AND PROGRAMMING GUIDE
SELF-CONTAINED ACCESS CONTROL SYSTEMS KEYPADS:
DOOR-GARDSELF-CONTAINEDACCESSCONTROLSYSTEMSofferfieldprovenreliabilityandcosteffectivesolutionsfor
residential,commercialandindustrialinstallations. Elegantyetdurable,Door•Gardsystemsblendwithvirtuallyany
decor.Designedforcompatibilitywithvirtuallyanyelectriclockingdevice,Door•Gardsacceptpowerfroma12or24V
AC/DCsupply.Noseparateprogrammerisevernecessary.
FEATURES:
•
LOCKRELEASERELAY
•
LOCK RELEASE TIMER
•
FORCED DOOR ALARM RELAY
•
PROPPED DOOR ALARM RELAY
•
ALARM ZONE SHUNTING RELAY
•
TIMED EGRESS INPUT
•
120 USERS
•
FRONT PROGRAMMING
MEMORY
Non-volatile EEPROM memory meansyourcodes and
instructionswillbetherewhetheryouremovepowerfor
5minutesor5 years.
CODES
TheDoor-GardSelf-ContainedAccessControlSystems
allowupto120 individualusercodestobevalid.Codes
maybefrom 1-6 digits inlengthanddigitsmaybe
repeated.TheMasterCodeisalwaysuserone(1)
FORCEDDOORRELAY
AssistedbytheDoorPosititionSensorInput,this1Amp
Form-Crelaywillenergizeifthedoorisopenedwithouta
validuserentryoregressinput.Thisoutputcanbepro-
grammedto energizeforupto15 minutesorlatch.It
canberesetbyavalidcodeentry.
PROPPEDDOORRELAY
Programminga1to15minuteopendoortimeallowsthe
Door-Gardtoalertyoutoaproppeddoorbyenergizinga1
AmpForm-Crelay.AssistedbytheDoorPositionSensor
Input,thisrelaywilldeenergizeuponclosureofthedoor.
ALARM ZONESHUNTRELAY
AssistedbytheDoorPositionSensorInput,this1Amp
Form-Crelayisenergizedsimultaneouslywiththelock
releaserelayprovidinganeasymeansofshuntingexisting
doorcontacts.Therelaywillcontinueshuntinguntilthe
Door•Gardseesthedoorclose;preventingnuisance
alarms(annunciatewiththeProppedDoorRelayinstead).
LOCKRELEASERELAY
Thisisan8Amp(10Ampsurge)Form-Crelaywhichcan
betoggled(bycode)ortimedfrom1to90seconds.
DOORPOSITIONSENSORINPUT
Bysimpleaddinganormallyclosedmagneticdoor
switch,theDoor•Gardsystemwillmonitortheposition
ofthedoorandimmediatelyrelock it aftervalidaccess
hasbeengained,preventingunwanted“tailgate” entries.
PROGRAMMING
Allprogrammingisaccomplishedentirelyfromthefront
ofthekeypad.LEDguidancemakesprogrammingeasy,
andchangingcodesamatterofsecondsforanautho-
rizeduser.
TIMED EGRESS INPUT
Uponamomentaryclosure,thisnormallyopenloopwill
trigger themainrelayfor the same time period as the
Master Code.
KEYPRESSFEEDBACK/ AUDIBLEKEYPRESS
Door-GardSelf Contained AccessControl Systems
willacknowledgeakeypressbymomentarilyilluminating
theyellowLEDontheindoor(i),weatherresistant(w),
mullion(m)stylesormomentarilysoundingthesounder
intheruggedized(r)andsealedenvironmental(se)styles.
Thiscanbeturnedoffthroughprogramming.
KEYPAD ACTIVE OUTPUT
Door-Gard Self Contained Access Control Systems canbe
programmedtoenergizeavoltageoutputwhenevera
keyistouched.Thiscanbeusedtoturnonlights,CCTV
camera,ornotifyaguard.Thisoutputisnot
availableiftheIEI250 PrinterInterfaceisused.
AUDIT TRAIL
Anaccuratereal-timeaudittrailcanbeprovidedbyany
Access Control Series Door-Gard (except 233/234) with
theadditionof amodel250 PrinterInterface(notinclud-
ed).Upto8keypadscanbemonitoredsimultaneously.
The250comeswithpowersupplyandprintercableand
easilyconnectstoanyparallelprinter(notincluded).
TESTING THE KEYPAD
1. Connect the positive (+) lead of your power
supply to the terminal strip (TS1) +V input.
2. Connect the negative (-) lead of your power
supply to the terminal strip (TS1) -V
input.Turn on your power supply.

1
2
2. To Change master code3
Press 1 # (new master code) * Flashes fast
Press (new master code) * Flashes slowly
If main relay time must be changed,
substitute option 2 from Programming
Options chart for step 2 above.
3. To Add/change second code
Press 2 # (new user code) * Flashes fast
Press (new user code) * Flashes slowly
4. To Add/change third code
Press 3 # (new user code) * Flashes fast
Press (new user code) * Flashes slowly
5. Up to 120 codes may be added in this fashion
Master Code (user 1) 1234 *
Lock Release Relay will energize for 5 secs.
Keypad Active Output Off
Keypress Feedback On
Propped door relay will energize after 30 secs.
Forced door relay will energize for 10 secs.
If defaults must be changed or additional functions
are desired, please refer to the PROGRAMMING
OPTIONS Chart after you are familiar with the
PROGRAMMING section.
PROGRAMMING
1. Enter programming mode1 Yellow LED2
Press 99 # (master code) * Flashes slow-
ly
6. Exit programming mode
Press * Out
NOTE:
•1 Door•Gard Self-Contained Access Control
Systems are factory programmed with a
master code of 1234 *.
•2 Some Door•Gard products contain a sounder in
place of the yellow LED. In these products the
flashing is replaced by a beeping.
•3 The master code is always user 1.
•The master code allows access to the
programming mode & activates the main relay.
•All codes must be followed by the *.
•Codes may be from 1-6 digits in length, and digits
may be repeated.
•If the master code is forgotten or does not seem to
be working, momentarily remove the programming
jumper (or push SW1 on the SE style, see wiring
diagram for location) to enter programming mode
and go to option #16 and default keypad.
•If the yellow LED lights (or soundersounds) solid
while in programmingmode an error has occurred.
Press * to clear (yellow LED should flash or sounder
sound) and start over from step 2 or 3 above.
PROGRAMMING OPTIONS CHART
If the pre-programmed default values must be changed
or additional functions are desired, the following
options may be programmed
4. Press 7890#123456*. If all 12 keypresses have
been verfied, the keypad will enter self test mode.
Either the LED’s will flash or the sounder will beep 3
times,.then light or sound continuously for 3 seconds
(except on the mullion). If these responses do not
happen, try the test mode again and then call tech
support. Note: self test mode can be used when trou-
bleshooting a keypad in the field. If you do not get the
continuous light or sound then the memory has been
corrupt and should be re-programmed with the 46
command (see option #16).
5. Enter the master code of 1234*. The relay will
energize. Refer to programming section to program
your keypad.
NOTE:
The keypad may be programmed in your shop or at the
installation site. Programmed information is stored in non-
volatile memoryso it will not be lost if power is removed.
ACCESS CONTROL DEFAULTS
Door-Gard Self-Contained Access Control Systems
are designed for easy installation in a minimum
amount of time. The following defaults have been fac-
tory programmed.

3
.
1. Enter programming mode
Press
99 # (master code) *
2. Change master code/set main relay time1
Press
(time) # 1 # (new code) * (new code) *
Example: Master code of 4321/relay time of 10 seconds Press 10 # 1 # 4321 * 4321 *
3. Add/change user code
Press
(user number) # (new code) * (new code) *
4. Add/change user code to toggle main relay1
Press
(00) # (user number) # (new code) * (new code) *
5. Delete user codes
Press
(user number) # * *
6. Turn keypress feedback/audible keypress on
Press
30 # 0 # 1 # **
7. Turn keypress feedback/audible keypress off
Press
30 # 0 # 0 # **
8. Turn yellow LED/sounder on with relay
Press
30 # 1 # 1 # **
9. Turn yellow LED/sounder off with relay
Press
30 # 1 # 0 # **
10. Turn auto entry on
Press
30 # 2 # 1 # **
11. Turn auto entry off
Press
30 # 2 # 0 # **
12. Turn keypad active on2
Press
43 # 0 # 99 # **
13. Turn keypad active off
Press
43 # 0 # 00 # **
14. Set propped door time3
Press
44 # (time) # 0 # * *
15. Set forced door relay time3
Press
45 # (time) # 0 # * *
16. Erase keypad memory/reset defaults
Press
46 # 00000 # 00000 # * *
NOTES:
1
Time must always be represented by 2 digits. Example: 5 seconds = 05.
Latching /toggle is accomplished by entering a time of 00
2
Keypad active is a negative voltage output (sink) available
on terminal (or wire) marked WB (see wiring diagrams for location).
3
Propped Door and Forced Door times must be programmed in intervals of
10 seconds. ie. 10, 30, 60, ... up to 900 seconds.Forced door time of 00 will latch output, until reset by code.

SELF CONTAINED ACCESS CONTROL SYSTEM STYLES:
232i-INDOOR STYLE
•Flushmount indoor design.
232w-WEATHER RESISTANT STYLE
•Flushmount outdoor design.
232r-RUGGEDIZED STYLE
•Weatherproof self-contained metal housing.
•Vandal resistant.
•Cast metal housing suitable for wall, post or
gooseneck mounting.
•Available in White or Black.
232se-SEALED ENVIRONMENTAL STYLE
•Weatherproof self-contained metal housing.
•Vandal resistant.
•Small design suitable for residential, commercial
and industrial applications.
232m-MULLION STYLE
•Weather resistant metal housing.
•Two-piece design with secured electronics.
•Narrow housing suitable for aluminum
door frame mounting.
•Available in Bronze or Satin Aluminum.
233 CARD READER SYSTEM
•Weatherproof metal housing.
•Two-piece design with secured electronics.
•Narrow style suitable for aluminum door frame mount-
ing.
•Uses any ABA standard track II magstripe card.
•120 users.
234 KEYPAD CARD READER SYSTEM
•Weatherproof metal housing.
•Uses any ABA standard track II magstripe card.
•Access via card, keypad or both.
•60 users.
ACCESSORIES:
DATA LOGGING
•IEI-250 P
RINTER INTERFACE
provides power, communica-
tion
inputs and outputs for up to 8 Door•Gard
Keypads. Interfaces
with any parallel printer for user/door activity logging.
INSTALLATION
•
IEI-280 WEATHERPROOF SURFACE BACK BOX.
•IEI-281 F
LUSH MOUNT BACK BOX
.
•IEI-290 12 VDC
PLUG
-
IN POWER SUPPLY
. 300MA.
•IEI-293 T
HREE RELAY PLUG
--
IN BOARD
with FORM C, 1 Amp
relays.
Converts transistor outputs to dry contacts (for use
with
Command and Control indoor, weather resistant and
mullion
styles).
MAGNETIC STRIPE CARDS –
Track II encoded, low coercivity cards.
•IEI-2010 –Pack of 10 cards.
•IEI-2025 –Pack of 25 cards.
TAMPER PROTECTION
•IEI-282 T
AMPER
S
WITCH
detects faceplate removal.
•IEI-283 S
ECURITY
M
ODULE
responds to tamper switch
(included)
and cuts all in/out power to the door lock. Wires can’t
be
crossed to unlock door. Must be reset from inside the
protected area.
•IEI-289 T
AMPER
S
CREWS
- T
RI
-
HEAD
.
•IEI-267 1/4”
DRIVER
.
•IEI-270
ADAPTER SOCKET
- T
RI
-
HEAD
.
•IEI-288 T
AMPER
S
CREWS
- A
LLEN WITH PIN
.
OTHER DOOR-GARD PRODUCTS FROM IEI
CONTROL PANEL INTERFACE SERIES
COMMAND & CONTROL SERIES KEYPADS
Please call to request more information.
LIMITEDWARRANTY
International Electronics, Inc. (IEI) warrants its products to be free from defects
in material and workmanship, when they have been installed in accordance with
the manufacturer’s instructions, and have not been modified or tampered with.
IEI does not assume any responsibility for damage or injury to person or proper-
ty due to improper care, storage, handling, abuse, misuse, normal wear and tear,
or an act of God.
IEI’s sole liability is limited to the repair or (at IEI’s option) the replacement of
the defective product or part when sent to IEI’s facility (freight and insurance
charges prepaid), after first obtaining IEI’s Return Merchandise Authorization.
IEI will not be liable to the purchaser or anyone else for incidental or conse-
quential damages arising from any defect in, or malfunction of, its products.
This warranty shall expire two years after shipping date for DOOR-GARD
keypads.
Except as stated above, IEI makes no warranties, either express or implied,
as to any matter whatsoever, including, without limitation to, the condition of its
products, their merchantability, or fitness for any particular purpose.
MADE INU.S.A.
605-0232
REV. 1.04