0.Introduction
DSTouch oscilloscope e combines the high performance of a des
ktop oscilloscope with the touch screen experience of a smartphone. I
n terms of performance, it utilizes FPGA-based hardware waveform en
gine architecture, and a large storage depth based on DRAM. In terms
of operation, it creatively designed a set of "single-finger touch" metho
ds, simplifying all functions into 1-3 tap and swipe operations
DSTouch oscilloscope is equipped with a built-in high-capacity lit
hium battery, making it an ideal palm-sized portable instrument.
1. Power On/Off
To prevent accidental power on/off caused by touching the powe
r button, DSTouch provides a long press power button to switch on/of
f and touch screen shutdown function
Button Power On/Off:
Touch Power Off(→ → ):
2. Run/Stop
DSTouch oscilloscope has physical and touch buttons for easy ru
n/stop control, meeting common usage needs.
Button Run/Stop:
Touch Run/Stop( ):
3. Probe
BNC interface on DSTouch allows compatibility with all standard
BNC probes, expanding usability.
Probe compensation:
Connect probe to oscilloscope's compensation reference signal.
Adjust probe compensation capacitor until waveform matches
desired display.
Probe attenuation
Match probe attenuation w
ith oscilloscope channel probe r
atio during use.
4. Autoset
DSTouch Oscilloscopes offer powerful autoset features for conve
nient and stable display of measured waveforms with a single button
press.
Button Autoset:
Touch Autoset(→):
5. Auto measurement
DSTouch oscilloscope simplifies adding/removing measurement
s on traditional scopes. Just a few taps to add/delete auto measurem
ents from a menu of 20 commonly used options.
Measurement Selection(→→):
Probe Extension Port
Auto
Run
停止
Stop
/
停止
Reserved Charging Contacts
Press & hold 3s to power off
Press this btn to autoset
1
Tap battery icon
2
1
2
Tap the auto btn
1
Choose auto channel
1
Choose display position for MEAS
2
Choose MEAS CH
3
Choose MEAS Items
Run/Stop Acquisition
Run/Stop Acquisition
3
Swipe right to turn off
Tap power off
Press & hold 1s to power on
Extension Port
Power Button
Type-C Port
Power Indicator
Charging Indicator
BNC Connector
Signal Generator
mcx Port
Probe Compensation
Reference

6. Trigger
DSTouch oscilloscope has reliable hardware triggering and
adjustable sensitivity and hold-off time.
Trigger level(→):
Trigger Options(→</>):
Trigger Sensitivity: Adjust the trigger level hysteresis window.
Smaller values provide more sensitive triggering, while larger values
increase stability in noisy signals.
Hold-off time: Delay period after each trigger before the trigger cir
cuit resumes operation. It prevents triggering during this interval, even
if the trigger conditions are met. Setting a reasonable hold-off time all
ows stable capture and analysis of burst signal waveforms, commonl
y seen in communication signals with alternating "idle" and "transmiss
ion" patterns.
7. Horizontal System.
Horizontal Timebase:
Meth 1: Default Win( )
Meth 2: Hori Adjust(→)
Hori Position():
8. Vertical System and Channel Options
Vertical Sensitivity:
Meth 1: Default Win(→/)
Meth 2: CH Opt Win(→/)
Vertical pos.(→):
Channel options(→):
9. Save/Load session and file operations
DSTouch oscilloscope offers 9 one-click switching sessions for
different testing scenarios, eliminating the need to repeatedly adjust o
scilloscope parameters.
The internal disk provided by the DSTouch oscilloscope can be
used for screenshots and connected to a computer as a U-disk
function. Firmware upgrades and other operations can be completed
through U-disk mode.
2
2
2
Scroll wheel
Scroll wave area up/
Step adjustment
1
Click waveform area
Tap to open CH options
1
On/Off Hori Adjust
Open options
1
Scroll wave area horiz.
Leftmost of wave
Trigger position
Rightmost of the wave
ON/OFF
Probe ratio adjust
CH color
Bandwidth limit
V/I selection
DC/AC coupling
1
2
Save current session to file
On/off file menu
Swipe L/R to
select session
Load session with one click
Delete current session file
on/off session
2
Adjust trigger options
/
Trig level
1
Tap to hit trig level
1
2
Drag to set trigger Level
Upper half +1
Lower half -1
Tap to increase vert range
Tap to decrease vert range
2
Scroll waveform up/down
Tap on upper/lower waveform
1
Select channel to adjust
1
Select channel
2
Drag up/down
Upper middle position
Middle position
Lower middle position
Tap to open CH options
1
Scroll wheel to adj vert range
2
Tog options
1
2
panel
down

Other file-related operations are shown in the following figure.
"format disk" will not affect the function of the oscilloscope, but all
user-related personalized settings will be cleared.
10. Quick Menu
DSTouch oscilloscope provides Quick Menu. Most operations can
be completed with the thumb while holding the oscilloscope with the
left hand, freeing up the other hand to fix the probe and test points.
Long-press on left can bring up the Quick Menu. Switch settings
for vertical, horizontal, and trigger options. Adjust settings by sliding in
the waveform area.
11. More Features
DSTouch oscilloscope offers additional practical features includi
ng FFT, protocol decoders, cursor measurements, X-Y mode, persisten
ce function, auto calibration, and signal generator, etc.
Check user manual and other docs for more on DSTouch.
Persistence & cursors
X-Y mode
Signal generator
Horizontal cursor value
Vertical cursor value
Tap to hit
on/off X-Y mode
on/off persistence mode
Exit X-Y mode
XY-axis and channel mapping
Signal type select
Adjust signal amplitude
Adjust signal frequency
on/off AWG options
On/off the signal generator
screenshot
enter the gallery
disk usage
connect to PC (USB mode)
1
format disk
Vertical options
Horizontal options
Autoset when running
Trigger options
Long-press left sidebar blank space
2
Other manuals for DSTouch
1
Other DreamSourceLab Test Equipment manuals
Popular Test Equipment manuals by other brands

VOLTCRAFT
VOLTCRAFT VC-65 SE operating instructions

Factair
Factair F6100 operating instructions

Unit
Unit UTD2000M operating manual

Kyoritsu Electrical Instruments Works, Ltd.
Kyoritsu Electrical Instruments Works, Ltd. KEW 5410 instruction manual

Unit
Unit UT501B operating manual

Black Box
Black Box VT-101 instruction manual