E2S BExCP3D-PB User manual

European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sa[email protected] Tel: +44 (0)208 743 8880
Document D150-00-151-IS Issue 6 11-08-2022 Sheet 1 of 3 www.e2s.com Fax +44 (0)208 740 4200
INSTRUCTION MANUAL
BExCP3B-PB, BExCP3D-PB & BExCP3E-PB Push Button Manual Call Point
For use
in
Flammable
Gas and
Dust Atmosphere
s
BExCP3B-PB, BExCP3D-PB &
BExCP3E-PB
Manual Call Point – Push Button
With resistor Modules
For use in Flammable Gas and
Combustible Dust Atmospheres
1) Introduction
The BExCP3B-PB/ BExCP3D-PB/ BExCP3E-PB is
a push button manual call point which is certified to
the European and International Gas and Dust
standards. The unit meets the requirements of the
ATEX directive 2014/34/EU and IECEx scheme.
The call point can be used in hazardous areas
where potentially flammable gas and dust
atmospheres may be present.
All units have up to two of the following series and/
or EOL devices:
Monitoring resistors per module: -
BExCP3B-PB - 2.0W Max
BExCP3D-PB - 1.0W Max
BExCP3E-PB - 1.75W Max
Monitoring diode
Monitoring Zener diode
The units are Group II, EPL (equipment protection
level) Gb. The equipment is certified ‘Ex db eb mb
IIC T4 Gb’ and as such may be used in Zones 1
and 2 with flammable gases and vapours with gas
groups IIA, IIB & IIC and temperature classes T1,
T2, T3 and T4.
These units are also Group III, EPL Db. The
equipment is certified
‘Ex tb IIIC T60ºC Db’ (BExCP3B-PB),
‘Ex tb IIIC T80ºC Db’ (BExCP3D-PB),
‘Ex tb IIIC T75ºC Db’ (BExCP3E-PB)
and as such may be used in Zones 21 and 22 for
combustible dusts groups IIIA, IIIB & IIIC.
2) Ratings & Marking
All units have a rating label, which carries the
following important information: -
Unit Type No.:
BExCP3B-PB Manual Call Point
BExCP3D-PB Manual Call Point
BExCP3E-PB Manual Call Point
Input Voltages:
48VDC nominal 56VDC Max 0.75A Max
24VDC nominal 28VDC Max 5.0A Max Resistive
Load; 3.0A Inductive Load
12VDC nominal 15VDC Max 5.0A Max
6VDC nominal 9VDC Max 5.0A Max
Code:
BExCP3B-PB
Ex db eb mb IIC T4 Gb
Ex tb IIIC T60ºC Db
IP66
–40ºC <= Ta <= +50ºC
BExCP3D-PB
Ex db eb mb IIC T4 Gb
Ex tb IIIC T80ºC Db
IP66
–40ºC <= Ta <= +70ºC
Certificate No.:
SIRA 09ATEX3286X
IECEx SIR 09.0121X
CSAE 21UKEX3556X
Epsilon x: II 2GD
CE Marking
Notified 2813
Body No.
UKCA Marking
Notified Body No. 0518
Year/Serial No. i.e. 20/1CP3BPB000001
Or 20/1CP3DPB000001
Or 20/1CP3EPB000001
WARNING - DO NOT OPEN WHEN AN
EXPLOSIVE ATMOSPHERE MAY BE PRESENT
3) Type Approval Standards
The beacon has an EC Type examination
certificate issued by SIRA and have been approved
to the following standards: -
EN60079-0:2018 / IEC60079-0:2017
EN60079-1:2014 / IEC60079-1:2014
EN60079-7:2015 / IEC60079-7:2017
EN60079-18:2015 / IEC60079-18:2014
EN60079-31:2014 / IEC60079-31:2013
The equipment is certified for use in ambient
temperatures in the range
BExCP3B-BG -40oC to +50oC
BExCP3D-BG -40oC to +70oC
BExCP3C-BG -40oC to +65oC
and shall not be used outside this range.
4) Installation Requirements
Installation of this equipment shall only be carried
out by suitably trained personnel in accordance
with the applicable code of practice e.g.
IEC 60079-14/EN 60079-14
Repair of this equipment shall only be carried out
by the manufacturer or in accordance with the
applicable code of practice e.g. IEC 60079-19/EN
60079-19.
Refer to certificates SIRA 09ATEX3286X, IECEx
SIR 09.0121X and CSAE 21UKEX3556X for
special conditions of safe use.
The certification of this equipment relies on the
following materials used in its construction:
Enclosure: Aluminium Pressure Die Cast Body
LM6
Through enclosure mechanism: Plastic Nylon Zytel
Injection Moulded
Sealing of enclosure and mechanism: O-ring
Acrylonitrile-Butadiene Rubber
Potting Compound of resistors where used: Epoxy
Resin
If the equipment is likely to come into contact with
aggressive substances, then it is the responsibility
of the user to take suitable precautions that prevent
it from being adversely affected, thus ensuring that
the type of protection is not compromised.
“Aggressive substances” - e.g. acidic liquids or
gases that may attack metals, or solvents that may
affect polymeric materials.
“Suitable precautions” - e.g. regular checks as part
of routine inspections or establishing from the
material’s data sheet that it is resistant to specific
chemicals.
5) Call Point Location and Mounting
The location of the call point should enable ease of
access for operation and testing. The unit should
be mounted using the 4 off fixing holes which will
accept up to M4 sized fixings.
View of base unit showing fixing centres.
To gain access to the mounting holes in the base
the front cover must be removed.
This is achieved by removing the 4 off M4 cap
head bolts holding on the cover.
BExCP3E-PB
Ex db eb mb IIC T4 Gb
Ex tb IIIC T75ºC Db
IP66
–40ºC <= Ta <= +65ºC

European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sa[email protected] Tel: +44 (0)208 743 8880
Document D150-00-151-IS Issue 6 11-08-2022 Sheet 2 of 3 www.e2s.com Fax +44 (0)208 740 4200
Once the screws are removed the cover will hang
down out of the way to gain access to the Ex e
terminal block, the internal earth terminal and
mounting hole recesses.
6) Earthing
The unit has both internal and external earth
terminals.
It is recommended that a cable crimp lug is used
on the earth wires.
The internal earth wire is placed under a earth
clamp which will stop the cable twisting. This
secured by an M4 screw and spring washer.
The external earth lug should be located between
the two M5 washers provided and securely locked
down with the M5 spring washer and two locknuts.
Internal Earth
terminals External
Earth Stud
Ex e terminal block
Note: Depending on options chosen an 8-Way DIN
Rail or 6-Way terminal block may be selected.
7) Cable connections
There are 3 off cable entry holes suitable for
M20x1.5 Ex e approved cable glands or stopping
plugs
The unit can be wired in a number of different ways
depending on the resistor combination selected.
For detail, refer to wiring schematic D150-06-051.
EOL (End of line) device;
resistor – ExxxR / diode – ED1 / zener – ExxxZ
Series (In line) device;
resistor – SxxxR / diode – SD1 / zener – SxxxZ
Microswitch 1 = M/S 1
Voltage
option
Max
Voltage
Min resistor
value
allowable in
module
Type B unit
(2.0W)
Min resistor
value
allowable
in module
Type D unit
(1.0W)
Min resistor
value
allowable
in module
Type E unit
(1.75W)
6 V dc 9 V dc 47 ohms 91 ohms 51 ohms
12V dc 15 V dc 120 ohms 240 ohms 150 ohms
24V dc 28 V dc 470 ohms 820 ohms 510 ohms
48V dc 56 V dc 1K8 ohms 3K3 ohms 2K0 ohms
When wiring to Increased Safety terminal
enclosures, you are only permitted to connect one
wire into each way on the terminal block, unless a
pair of wires are crimped into a suitable ferrule.
For the six-way terminal block wire sizes allowable
are 0.5mm² to 4.0mm². For the 8-way DIN rail wire
sizes allowable are 0.5mm² to 2.5mm².
Leads connected to the terminals shall be insulated
for the appropriate voltage and this insulation shall
extend to within 1mm of the metal of the terminal
throat. They shall only be installed and wired with
cable in an ambient temperature of -10°C to +80°C
All terminal screws, used or unused, shall be
tightened down to between 0.5 Nm and 0.7 Nm
7.1) Fitted LED, Diode or Zener Diode
If a diode module is pre-fitted as either an EOL or
series device, the following current limitation
applies:
Unit
Voltage
Max
.
Current
48V DC
0.75A
6, 12 & 24V DC 2.0A
If a Zener diode module is pre-fitted as either EOL
or Series device, the following current limitation
applies:
Zener
Vo
ltage
Max. Input
Voltage
Max. Current
3.3V
56V DC
230mA
4.7V
162
mA
5.1V
149mA
5.6V
136mA
6.2V 122mA
6.8V
112mA
10V
76mA
12V
63mA
In any scenario, the lowest value of maximum
current should be used. For example, if the unit
has both a diode and a Zener diode, the Zener
diode would determine the maximum input current
of the unit, since its max. current is lowest.
8) Testing unit operation
The push button unit can be tested without the
need to replace any element.
To test, lift the cover lift flap to reveal the push
button. The button should be pressed into the body
to activate the unit and place it into the operated
condition.
The call point switch will now change over its
contacts to operate the alarm.
Once testing is complete the unit needs to be reset
from the operated condition.
Rotate the push button anticlockwise by an angle
of 55º, see guide alignment marks on button and
cover, shown below (1). The push button should
pop back up to its original position.
Ensure that the push button has also twisted back
clockwise by 55º to its original position see guide
marks on button and cover, shown below (2).
The unit is now reset.
1. On operated unit 2. Button should pop
Twist push button up and twist back to
Anticlockwise 55º original position
to reset
Note: use alignment
marks circled to
indicate the push
button’s status
/position.
Unit currently shown
as ‘standby
condition’
Resetting an operated unit is the same as resetting
a tested unit.

European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sa[email protected] Tel: +44 (0)208 743 8880
Document D150-00-151-IS Issue 6 11-08-2022 Sheet 3 of 3 www.e2s.com Fax +44 (0)208 740 4200
9) SIL 2 Reliability Data
Reliability and Functional safety IEC/EN61508
which has been assessed and is considered
suitable for use in low demand safety function:
• Random Hardware Failures and Systematic
Failures (route 2H)
• As an unvoted item (i.e. hardware fault tolerance
of 0) at SIL 2
The product was assessed against failure modes:
• Failure to close a contact when the call point is
struck with specified force
• Failure to open a contact when the call point is
struck with specified force
• Spurious output despite no input
Integrity in respect of failure to
close
SIL 2
Total Failure rate 0.133 pmh
“hazardous” failure rate (revealed) 0 pmh
“hazardous” failure rate
(unrevealed)
0.1 pmh
“safe” failure rate (revealed) 0.033 pmh
“safe” failure rate (unrevealed) 0
Diagnostic Coverage 99%
System type A
Hardware Fault Tolerance 0
Safe Failure Fraction >99%
PFD (hazardous failure) 1.25 x 10-3
Proof Test Interval Up to 1 year

2 3 4
+
-
2 3 4
+
-
DEVICE POLARITY
ZENER
DIODE
DIODE
M/S 1
EOL
-
+
M/S 1
-
+
87654321
R Y B
M/S 1
SERIES
-
+
M/S 1
-
+
87654321
R Y B
M/S 1
SERIES
EOL
-
+
M/S 1
-
+
87654321
R Y B
SERIES
M/S 1
EOL
-
+
M/S 1
-
+
87654321
R Y B
3 4
+
-
3 4
+
-
DIODE
ZENER
DIODE
DEVICE POLARITY
+
21
+
21
DEVICE POLARITY
ZENER
DIODEDIODE
2
+
3
+
4
-
5
-
EOL
SERIES
5
-
4
-
3
+
2
+
2
+
3
+
4
-
5
-
EOL
SERIES
SERIES
EOL
5
-
4
-
2
+
1
+
Series Device
EOL Device
Voltage
Product Version
BEXCP3B-BG[s][t][l][e][m][d][v][x][n]-[v][e][s]
--
2 3 4
+
-
+
DIODE
ZENER
DIODE
DEVICE POLARITY
2 3 4
+
-
+
D.HOWGILL
warning signals
2S
BExCP3B/C/D/E CALL POINTS
3
ACN0077
2ADDED. D.A.H - 26-08-2020
INTRODUCTION
WWW.E2S.COM
C
LONDON W3 7QH
ACTON
MANSELL ROAD
IMPRESS HOUSE
EUROPEAN SAFETY SYSTEMS LTD
1
07-02-20
07-02-20
AS PER LATEST DATE OF ISSUE SHOWN ABOVE
EUROPEAN SAFETY SYSTEMS LTD.
WRITTEN CONSENT.
MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR
ANGULAR DIMENSIONAL TOLS
STANDARDS
MOD No. REASON - INITIAL - DATEISSUE
DATE
APPROVED
CHECKED DATE
DATE
DRAWN WEIGHT (Kg)
SURFACE FINISH
MATERIAL
ALTERNATIVE MATERIAL SHEETSCALE
TITLE
A3
LINEAR DIMENSIONAL TOLS
DO NOT SCALE
ALL DIMENSIONS IN MM
DRAWING NUMBER
A
B
C
D
E
F
G
109
G
F
E
78
6
5
D
C
134
2
A
B
D150-06-051
R.N.POTTS
TYPE E ADDED ; SIMPLIFIED DIAGRAMS
R.N.POTTS
07-02-20
OF
IF IN DOUBT, ASK -
CALL POINT WIRING SCHEMATIC
BExCP3B/C/D/E-BG/PB/PT MANUAL
D.A.H - 07-02-2020
NTS 1 1
THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE
MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND
IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY
SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY
BE DISCLOSED, LOANED, COPIED OR USED FOR
DRAWING TO BS8888:2000
GEOMETRIC TOLERANCES TO ISO1101:1983
DEVICE POLARITY DETAIL ADDED ;
CODING UPDATED D.A.H - 21-12-2021
Circuit shown in Unoperated condition
Unoperated condition
(Glass Intact / Standby Condition)
Terminals +(1,2) & -(4,5) M/S 1 open
Terminals +(1,2) & (6) M/S 1 closed
Operated condition
(Glass Broken / Button pushed in)
Terminals +(1,2) & -(4,5) M/S 1 closed
Terminals +(1,2) & (6) M/S 1 open
Circuit shown in Unoperated condition
Unoperated condition
(Glass Intact / Standby Condition)
Terminals +(2,3) & -(4,5) open
Terminals +(2,3) & (6) closed
Operated condition
(Glass Broken / Button pushed in)
Terminals +(2,3) & -(4,5) closed
Terminals +(2,3) & (6) open
Circuit shown in Unoperated condition
Unoperated condition
(Glass Intact / Standby Condition)
Terminals +(2,3) & -(4,5) open
Terminals +(2,3) & (6) closed
Operated condition
(Glass Broken / Button pushed in)
Terminals +(2,3) & -(4,5) closed
Terminals +(2,3) & (6) open
Circuit shown in Unoperated condition
Unoperated condition
(Glass Intact / Standby Condition)
Terminals +(2,3) & -(4,5) open
Terminals +(2,3) & (6) closed
Operated condition
(Glass Broken / Button pushed in)
Terminals +(2,3) & -(4,5) closed
Terminals +(2,3) & (6) open
Single
Alternative Wiring
EOL + Series
[S]
[W]
[Exxxx][Sxxxx]
Single
Standard
EOL + Series
[S]
[1]
[Exxxx][Sxxxx]
Single
Standard
Series Device
[S]
[1]
[Sxxxx]
Single
Standard
EOL Device
SWITCH TYPE [s]
PRODUCT OPTION [o]
SERIES MODULE [s]
[S]
[1]
[Exxxx]
CONFIG. 4CONFIG. 3
SWITCH TYPE [s]
PRODUCT OPTION [o]
MODULE [e][s]
SINGLE SWITCH WITH EOL & SERIES DEVICE
SWITCH TYPE [s]
PRODUCT OPTION [o]
MODULES [e][s]
SINGLE SWITCH WITH EOL & SERIES DEVICECONFIG. 2CONFIG. 1SINGLE SWITCH WITH EOL DEVICE
SWITCH TYPE [s]
PRODUCT OPTION [o]
EOL MODULE [e]
SINGLE SWITCH WITH SERIES DEVICESINGLE SWITCH WITH EOL DEVICE
SINGLE MICROSWITCH WITH DEVICES
Module Device Codes
EOL Series
Resistor ExxxR SxxxR
Diode ED1 SD1
Zener Diode ExxxZ SxxxZ
LED N/A L or C
Notes:
1. Other configurations of dual switch units are possible.
Contact E2S sales to discuss options.
PRODUCTS:
BExCP3B/C/D/E - BG
BExCP3B/C/D/E - PB
BExCP3B/C/D/E - PT
SINGLE SWITCH WITH EOL & SERIES DEVICE SINGLE SWITCH WITH EOL & SERIES DEVICE
Single
Standard
EOL + Series
Single
Alternative Wiring
EOL + Series
Circuit shown in Unoperated condition
Unoperated condition
(Glass Intact / Standby Condition)
Terminals +(2,3) & -(4,5) open
Terminals +(2,3) & (6) closed
Operated condition
(Glass Broken / Button pushed in)
Terminals +(2,3) & -(4,5) closed
Terminals +(2,3) & (6) open
Circuit shown in Unoperated condition
Unoperated condition
(Glass Intact / Standby Condition)
Terminals +(2,3) & -(4,5) open
Terminals +(2,3) & (6) closed
Operated condition
(Glass Broken / Button pushed in)
Terminals +(2,3) & -(4,5) closed
Terminals +(2,3) & (6) open
Circuit shown in Unoperated condition
Unoperated condition
(Glass Intact / Standby Condition)
Terminals +(2,3) & -(4,5) open
Terminals +(2,3) & (6) closed
Operated condition
(Glass Broken / Button pushed in)
Terminals +(2,3) & -(4,5) closed
Terminals +(2,3) & (6) open
Circuit shown in Unoperated condition
Unoperated condition
(Glass Intact / Standby Condition)
Terminals +(1,2) & -(4,5) M/S 1 open
Terminals +(1,2) & (6) M/S 1 closed
Operated condition
(Glass Broken / Button pushed in)
Terminals +(1,2) & -(4,5) M/S 1 closed
Terminals +(1,2) & (6) M/S 1 open

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sale[email protected] www.e2s.com DC-007_Issue_N (BExCP3) - Page 1 of 2 - QAF_252_Issue_5
EU Declaration of Conformity
Manufacturer: European Safety Systems Ltd.
Impress House, Mansell Road, Acton
London, W3 7QH
United Kingdom
Authorised Representative: E2S Warnsignaltechnik UG
Charlottenstrasse 45-51
72764 Reutlingen
Germany
Equipment Type: BExCP3A-BG, BExCP3A-PB, BExCP3A-PT, BExCP3B-BG, BExCP3B-PB, BExCP3B-PT,
BExCP3C-BG, BExCP3C-PB, BExCP3C-PT, BExCP3D-BG, BExCP3D-PB, BExCP3D-PT,
BExCP3E-BG, BExCP3E-PB, BExCP3E-PT
Directive 2014/34/EU: Equipment and Protective Systems for use in Potentially Explosive Atmospheres (ATEX)
Notified Body for EU type Examination (Module B):
Sira Certification Service
Notified Body No.: 2813
CSA Group Netherlands B.V, Utrechtseweg 310, 6812 AR, Arnhem, Netherlands
EU-type Examination Certificate (Module B):
SIRA 09ATEX3286X
Notified Body for Quality Assurance Notification / Conformity to EU-type
based on
quality assurance of the production process (Module D):
Sira Certification Service
Notified Body No.: 2813
CSA Group Netherlands B.V, Utrechtseweg 310, 6812 AR, Arnhem, Netherlands
Quality Assurance Notification (Module D):
SIRA 05 ATEX M342
Provisions fulfilled by the equipment: BExCP3A:
BExCP3B:
BExCP3C:
BExCP3D:
BExCP3E:
II 2G Ex db eb IIC T6 Gb (-40°C ≤ Ta ≤ +70°C)
II 2D Ex tb IIIC T75°C Db (-40°C ≤ Ta ≤ +70°C)
or
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +50°C)
II 2D Ex tb IIIC T60°C Db (-40°C ≤ Ta ≤ +50°C)
or
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +65°C)
II 2D Ex tb IIIC T75°C Db (-40°C ≤ Ta ≤ +65°C)
or
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +70°C)
II 2D Ex tb IIIC T80°C Db (-40°C ≤ Ta ≤ +70°C)
or
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +65°C)
II 2D Ex tb IIIC T75°C Db (-40°C ≤ Ta ≤ +65°C)
Standards applied:
EN IEC 60079-0:2018
EN 60079-1:2014
EN 60079-7:2015/A1:2108
IEC 60079-18:2015/AC:2018
EN 60079-31: 2014
IP6X Dust Protection to EN60079-0 / EN 60079-31
Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)
Standards applied:
EN 61000-6-1:2007
EN 61000-6-2:2005
EN 61000-6-3:2007 / A1:2011 / AC: 2012
EN 61000-6-4:2007 / A1:2011
Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic
equipment, including amendment by Directive 2015/863/EU.

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sale[email protected] www.e2s.com DC-007_Issue_N (BExCP3) - Page 2 of 2 - QAF_252_Issue_5
Martin Streetz
Document No.:
DC-007_Issue_N
Quality Assurance Manager
Date and Place of Issue:
London, 23/12/2020
EU Declaration of Conformity
Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
The product and all the components contained within it are free from substances of very high concern.
Other Standards and Regulations
EN 60529:1992+A2:2013 - Degrees of protection provided by enclosures (IP code) –enclosure rated IP66
Construction and design requirements according to EN54-11:2001 clause 4.7 –BExCP3A-BG / B-BG / C-BG / D-BG only (fitted with burning house symbol shown in
figure 3a and no lift flap)
On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment
conforms with all technical and regulatory requirements of the above listed directives, regulations and standards.
This Declaration is issued under the sole responsibility of the manufacturer.

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] www.e2s.com DC-093_Issue_A (BExCP3) - Page 1 of 2 - QAF_252_Issue_5
UKCA Declaration of Conformity
Manufacturer: European Safety Systems Ltd.
Impress House, Mansell Road, Acton
London, W3 7QH
United Kingdom
Equipment Type: BExCP3A-BG, BExCP3A-PB, BExCP3A-PT, BExCP3B-BG, BExCP3B-PB, BExCP3B-PT,
BExCP3C-BG, BExCP3C-PB, BExCP3C-PT, BExCP3D-BG, BExCP3D-PB, BExCP3D-PT,
BExCP3E-BG, BExCP3E-PB, BExCP3E-PT
Directive UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres
(UKCA)
Notified Body for
UK
type Examination
(Module B)
:
Sira
Certification Service
Notified Body No.: 0518
Rake Lane, Eccleston, Chester CH4 9JN, UK
UK
-
type Examination Certificate
(Module B)
:
CSAE 21
UKEX3556X
Notified Body for Quality Assurance Notification
/
Conformity to EU
-
type
based on
quality assurance of the production process (Module D):
Sira
Certification Service
Notified Body No.: 0518
Rake Lane, Eccleston, Chester CH4 9JN, UK
Quality Assurance Notification
(Module D)
:
CSAE 22UKQAN0046
Provisions fulfilled by the equipment:
BExCP3A
:
BExCP3B:
BExCP3C:
BExCP3D:
BExCP3E:
II 2G Ex
db
e
b
IIC T6 Gb
(
-
40°C
≤ Ta ≤ +
70
°C)
II 2D Ex tb IIIC T75°C Db (-40°C ≤ Ta ≤ +70°C)
or
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +50°C)
II 2D Ex tb IIIC T60°C Db (-40°C ≤ Ta ≤ +50°C)
or
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +65°C)
II 2D Ex tb IIIC T75°C Db (-40°C ≤ Ta ≤ +65°C)
or
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +70°C)
II 2D Ex tb IIIC T80°C Db (-40°C ≤ Ta ≤ +70°C)
or
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +65°C)
II 2D Ex tb IIIC T75°C Db (-40°C ≤ Ta ≤ +65°C)
Standards applied:
EN IEC
60079
-
0:2018
EN 60079-1:2014
EN 60079-7:2015/A1:2108
IEC 60079-18:2015/AC:2018
EN 60079-31: 2014
IP6X Dust Protection to EN60079-0 / EN 60079-31
Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)
Standards applied:
EN
61000
-
6
-
1:2007
EN 61000-6-2:2005
EN 61000-6-3:2007 / A1:2011 / AC: 2012
EN 61000-6-4:2007 / A1:2011
Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic
equipment, including amendment by Directive 2015/863/EU.
Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
The product and all the components contained within it are free from substances of very high concern.

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] www.e2s.com DC-093_Issue_A (BExCP3) - Page 2 of 2 - QAF_252_Issue_5
Martin Streetz Document No.: DC-093_Issue_A
Quality Assurance Manager Date and Place of Issue: London, 24/02/2022
UKCA Declaration of Conformity
Other Standards and Regulations
EN 60529:1992+A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66
Construction and design requirements according to EN54-11:2001 clause 4.7 – BExCP3A-BG / B-BG / C-BG / D-BG only (fitted with burning house symbol shown in
figure 3a and no lift flap)
On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment
conforms with all technical and regulatory requirements of the above listed directives, regulations and standards.
This Declaration is issued under the sole responsibility of the manufacturer.
This manual suits for next models
2
Table of contents
Other E2S Fire Alarm manuals
Popular Fire Alarm manuals by other brands

Eridan
Eridan IP535-07ea-RS Operation manual

INIM Electronics
INIM Electronics Praesidia series GUIDE TO NETWORKING

Teletek electronics
Teletek electronics SensoMAG MRB50 installation instructions

Honeywell
Honeywell Silent Knight IntelliKnight 5820XL Installation and operation manual

olympia electronics
olympia electronics BSR-1001 manual

Apollo
Apollo SA5900-908 installation guide