2Eastwood Technical Assistance: 800.544.5118 >> techelp@eastwood.com To order parts and supplies: 800.345.1178 >> eastwood.com 3
ASSEMBLY
• Thread the Flexible Metal “Gooseneck” Fluid
Outlet Tube onto the Pump Outlet Fitting (Fig A).
• Place the Parts Cleaning Tray over the ledges
on the walls of the tub. Make sure the Nozzle
of the Flexible Metal “Gooseneck” Fluid Outlet
Tube is shaped to be facing in and downward
toward the center of the Tub (Fig B).
• Fill unit with suitable, water-based degreasing
solution sufficiently to cover the entire Pump
(approx. 1.5 gallons) (Fig C).
Important Notes:
- Follow degreasing solution mixing, usage
and safety label instructions carefully
before using.
- Be sure the cleaning solution level fully
covers the Pump or it will not function
properly.
• Plug power cord into an approved, grounded
and GFI equipped 120 Volt AC, 60hz. outlet.
• Turn Power Switch to the “On” position.
The Parts Washer is now ready for use.
OPERATION
• Place parts to be cleaned on the Parts Tray.
• Allow cleaning solution to flow completely over
the part surface, wetting it completely. Allow
time for solution to soften any grease and
debris then use a suitable parts cleaning
brush to remove stubborn deposits.
• Let excess solution drain from parts then
remove from washer and rinse in warm water.
• When done, turn pump to the off position,
close lid and unplug unit.
Your Eastwood 3.5 Gallon Benchtop Parts Washer is specifically designed with heavy-duty
components and a quality powder-coated finish to provide years of trouble-free service. It features
a flexible, positionable metal “Gooseneck” fluid outlet tube with nozzle for added convenience.
SAFETY INFORMATION
SPECIFICATIONS
• 120 Volt AC, 60hz current requirement
• Maximum pump capacity @ outlet: 1 gallon per minute
• 3.5 gallon tub capacity, 1.5 gallon operating capacity
INCLUDES
(1) 3.5 Gallon capacity tub (1.5 gallon actual operating capacity)
(1) Parts tray
(1) Flexible, positionable metal “Gooseneck” fluid outlet tube with nozzle
READ INSTRUCTIONS!
Thoroughly read and understand manual before using this Parts Washer Tool.
Save for future reference.
WARNINGS!
• NEVER use solvent based or flammable cleaning agents in this parts washer.
The recirculating pump is designed to operate with water based cleaning agents
only. Solvents will quickly destroy the pump and could present a fire hazard.
• DO NOT use paint or powder dissolving solutions that would remove the
powdercoated finish of the Tub and components.
• NEVER let parts washer run while unattended. Clogging of the filter and resulting
overheating of the pump motor can occur.
• ALWAYS plug into an approved, grounded and GFI equipped 120 Volt AC,
60hz. outlet.
• For indoor use only.
• ALWAYS wear chemical resistant gloves and adequate eye protection.
Fig. A
Fig. B
Fig. C