EasyIO EasyIOeu SH-SystemView7 Instruction sheet

EasyIOeu SH-SystemView7 Configuration
1
!
!
!
EasyIOeu!SH-SystemView7!Configuration!v1.9!
!
! ! ! !
! !

EasyIOeu SH-SystemView7 Configuration
2
Document Change Log
30th Jun 2015
Document created.
4th Aug 2015
Updated some info.
!
12th Jan 2016
Updated info about SystemView app.
31th Aug 2016
Clarify info about SystemView app.
23th Apr 2017
Update to SystemView 2.0a app and new Android touch panel version.
29th Aug 2017
Update SystemView pages.
10th Nov 2017
Update measurement.
28th Jan 2019
Update to Android 6.0.
24th May 2019
Update mounting instructions.
!

EasyIOeu SH-SystemView7 Configuration
3
!
Table&of&Contents&
Introduction ............................................................................................................................................ 4
Specifications .......................................................................................................................................... 5
Dimension ............................................................................................................................................... 6
Hardware Installation - Flush mounting ................................................................................................. 7
Ethernet/Date & time ............................................................................................................................. 9
SystemView 2.0a .................................................................................................................................. 10
SystemView 2.0a Settings ..................................................................................................................... 11
Configurations ...................................................................................................................................... 12
Technical Support ................................................................................................................................. 13
!

EasyIOeu SH-SystemView7 Configuration
4
Introduction!
Thank you for purchasing EasyIO products.
This user guide will help you to configure SystemView7 in a fast and efficient manner.
This device is based on Android OS and so there are several settings that device is expecting to get
from the network in order to work properly.
Date & Time
IP Address
If you are using the device without connection to Internet / DHCP Router make sure you setup this
properties correctly in order to get the device working correct.
As Android device gets the date and time from the Internet on every power up.
Please note that these SystemView touch panels are developed to present the graphic pages from
the EasyIO controllers.
Every other use of these touch panels should be tested prior to commissioning.

EasyIOeu SH-SystemView7 Configuration
5
!
Specifications!
Model:
SystemView7
Hardware Specs
Processor:
Allwinner A83T processor
CPU:
8-Core ARM Cortex A7 CPU, 1.2Ghz
Display:
7 Inch IPS Display, Resolution:1024 x 600,
Brightness: 350 cd/m2
RAM:
2GB
Nand Flash:
8GB
Software Feature
System:
Google Android 6.0.1
Video:
H.264 2160p video decoding,
Multi-format FHD video decoding, including
Mpeg1/2, Mpeg4 SP/ASP GMC, H.263, H.264,
VP6/8, AVS jizun, Jpeg/Mjpeg,etc.
H.264 High Profile 1080p@30fps or 720@60fps
encoding
3840 x 1080@30fps 3D decoding, BD/SBS/TAB/FP
supported
Complies with RTSP, HTTP, HLS, RTMP, MMS
streaming media protocols
Audio:
Two Speakers 2 X 1 Watt (Integrated 3W Amplifier
For External Speakers)
Language:
Support multi-languages
Interfaces
Back:
HDMI Out
DC IN Power Plug
Ethernet Interface (RJ45)
USB Port 2.0
Network
WIFI
WIFI (802.11b/g/n)
LAN Port
Ethernet RJ45
Accessories
Power Supply:
Power Supply: 12V/1500mA
Mounting:
Integrated bracket for in/on-wall mounting and
metal clips for flush mounting.
!

EasyIOeu SH-SystemView7 Configuration
6
Dimension!

EasyIOeu SH-SystemView7 Configuration
7
Hardware!Installation!-!Flush!mounting!
Step 1
Make the cut-out for the touch panel (dimensions in millimeters).
Step 2
Place it in the touch panel cut-out.

EasyIOeu SH-SystemView7 Configuration
8
Step 3
Put the 4 brackets into the touch panel backplate holes.
Step 4
Tighten the screw to secure the touch panel to the panel (4x).
Allen key 2,5mm

EasyIOeu SH-SystemView7 Configuration
9
Ethernet/Date!&!time!
To connect the touch panel to some device by Ethernet you need to configure the Ethernet network.
This needs to be done in the Android system settings.
Go to Settings->Ethernet, enable Ethernet and if you want to use Static IP address click on Static IP
• Set the IP Address of your SystemView7;
• Set the Subnet mask of your network (usually 255.255.255.0);
• Set the Gateway.
• Set the DNS1 and DNS2. (8.8.8.8 and 8.8.4.4 for Google DNS or set the IP of the router as
your DNS)
Don’t use/enable both networks at same time, Ethernet and Wi-Fi.
To have your touch panel showing the graphics in the right time you need to make sure you have the
date and time updated.
Disable Automatic time zone and Select time zone of your country. If the touch panel is not
connected to internet disable Automatic date & time, so Set date and Set time.

EasyIOeu SH-SystemView7 Configuration
10
SystemView!2.0a!
This app was made to keep the web page opened and to exit only through password.
SystemView app will open on boot and even when the touch panel reboots it will open
automatically.
To configure this app you just need to set the IP of your device and first time you power the touch
panel you need to set to open this app always on boot.
How to exit from SystemView
To exit from SystemView you have to swipe down on top of the screen, then press the three dots in
the top right corner and then click on Settings. You will be prompted to enter a password, the
default password is “345710ʺ (without quotation marks). On SystemView Settings you can change
the settings of the app, if you want to go to Android Settings or Android launcher you have to go to
Admin and then click on System Settings or Exit to Launcher depending on where you want to go.
How to change the IP on SystemView
To change the IP on SystemView you need to go to SystemView Settings (step above), then click on
General and change the SystemView URL. (it has to start with http:// or https://)
How to exit from Android Settings
To exit from Android Settings you need to go to Settings>Apps click on Settings and then Force Stop.
Doing this you are stopping the Settings and then it will open the SystemView (if you were there
before).
How to install a new SystemView version
To install a new version of SystemView first go to Settings->Apps and click on SystemView then
Uninstall.
Power down the touch panel and connect an USB stick with the latest SystemView app.
Power on and go to Menu->File Manager->USB->usbhost0 and click on latest SystemView apk file.
Installation will start.
Power down and remove the USB stick.

EasyIOeu SH-SystemView7 Configuration
11
Power on and go to SystemView Settings->Advanced, Set “Prevent keyboard form submission” OFF.
SystemView!2.0a!Settings!
Screensaver and Auto-refresh
SystemView app has an Auto-refresh and Screensaver option enabled by default, this means after 5
minutes the SystemView app will open the screensaver (black image) and it will keep refreshing the
web page on background every 5 minutes.
General
Idle Page Timeout
Enables page timeout, causes reload of SystemView URL and displays screensaver if enabled.
(Default = ON)
Timeout
Specified in minutes, the time that SystemView is considered to be idle.
(Default = 5 minutes)
Features
Screensaver
Display screensaver when the idle timeout limit has been reached.
(Default = ON)
Zoom on web page
The zooming is enabled by default so the zoom in/out can be done on the web page. When
SystemView loads/reloads the web page it will show in Overview mode by default, it can also
loads/reloads the page based on a Initial Zoom Level.
General
Page Zooming
Enables pinch zooming/double tap – note changes may require restart.
(Default = ON)
Overview Mode
Loads page in overview i.e. zoomed out – may require restart.
(Default = ON)
Initial Zoom Level
Zoom when page first loads, setting to zero disables. Overrides overview mode if enabled.
(Default = 0)
! !

EasyIOeu SH-SystemView7 Configuration
12
Configurations!
By default this SystemView device must come with this configuration from factory, anyway you can
check these configuration to make sure it works correctly.
- SystemView 2.0a app installed.
- screensaver.png image must be pasted into folder /storage/emulated/0/systemview/screensaver/
Settings:
Display
- Hide status bar -> enable;
- SystemUI Gestures -> disable; (Make sure this is disabled)
Location
- Off;
Language & input
- Language -> English;
Date & time
- Automatic time zone -> disable;
- Select time zone -> GMT+02:00, Central European Summer Time (Amsterdam, Berlin);
- Use 24-hour format -> enable;
Developer options
- Stay awake -> enable;
- Show touches -> enable;
- Don't keep activities -> enable;

EasyIOeu SH-SystemView7 Configuration
13
Technical!Support!
To get the latest software or for any technical question contact technical support.
Email:[email protected]u
Table of contents
Other EasyIO Control Unit manuals
Popular Control Unit manuals by other brands

Sony
Sony HDCU4300 Operation manual

SilverStone
SilverStone LSB01 installation guide

Yingli Solar
Yingli Solar YL P-35b Series Installation and user manual

GBD
GBD BA100 Instructions for installations

Trenz Electronic
Trenz Electronic TEC0117 Schematics

Bosch
Bosch Rexroth IndraControl XFE 01.1 Series operating manual

Booth & Co
Booth & Co AXBRIDGE user guide

Texas Instruments
Texas Instruments LED171596AEVM user guide

DH Instruments
DH Instruments CONSTANT VOLUME VALVE installation instructions

Telit Wireless Solutions
Telit Wireless Solutions CC864-DUAL Hardware user's guide

Opentrons
Opentrons GEN1 quick start guide

AVK
AVK 41 Series Operation and maintenance instructions