EasyPro Eco-Clear EC2600U Use and care manual

1
EC1300 • EC1300U
How does the Eco-Clear
Pressure Filter work?
These lters receive dirty water
from the pump and return sparkling
clear water to your pond. The EasyPro
pressure lter is ideal for pond keepers who
want simplicity, clear water and an attractive,
hidden lter system.
Eco-Clear
Pressurized Filters
Instructions for Operation • Safety • Warranty

2
Pressure Filter Installation
Please read all instructions carefully and keep for future reference
Safety and Electrical Connections
• Always disconnect the electrical supply before starting to handle, maintain, repair
or install any pond equipment.
• This product is not submersible, and it must be situated where it cannot fall into the water.
However, the design is weather resistant, and EasyPro Eco-Clear lters can safely be
installed outdoors.
• Direct exposure to ultraviolet light can damage eyes and skin. Do not attempt to
view the lamp when lit.
• Connect UV units only to a receptacle protected by a Ground Fault Circuit Interrupter.
(GFCI)
• Protect from the frost. In freezing climates, drain the lter and remove from the ground and
store in a warm dry place to avoid damage caused by ice.
• All electrical work must be performed by a qualied technician. Always follow the National
Electrical Code (NEC) or the Canadian Electrical Code as well as all local, state and
provincial codes. Code questions should be directed to your local electrical inspector.
Failure to follow electrical codes and OSHA safety standards may result in personal injury
or equipment damage. Failure to follow manufacturer’s installation instructions may result
in electrical shock, re hazard, personal injury or death, damaged equipment, provide
unsatisfactory performance and may void manufacturer’s warranty.
Installation of the Eco-Clear Pressure Filter
1. The EC1300U comes with the UV light already installed.
2. Position pump at the furthest point from the waterfall for best circulation. Run the tubing
out of the pond to the lter. Bury or conceal the tubing as desired.
3. Solids handling Eco-Clear pumps work well with the Eco-Clear Filters.
4. Position the pressure lter anywhere around the pond. Avoid placing the lter where it
could get ooded or fall into the pond. Since the discharge is under pressure, the lter
can be located downhill from the waterfall. For units with UV lights, be sure the power
cord can reach your outlet.
5. Dig a hole big enough for the lter to sit in and at a
depth where the retaining ring is left exposed out of
the ground to allow for easy maintenance.
6. Recess the lter into the previously dug hole and
carefully backll around the lter.
7. To maximize ow performance, use a hacksaw to
remove any smaller steps on the barb tting than the
tubing being used.
Step 7
Cut here for
1" tubing
Cut here for
3/4" tubing

3
8. Secure the prepared barb ttings to the lter inlet
(arrow pointing in) and outlet (arrow pointing out).
Be sure to use the gasket as shown and hand
tighten nut onto lter. Do not overtighten.
9. Connect the tubing from the pump to the barbed
tting on the inlet of the lter and secure with a
clamp.
10. Connect the tubing for the waterfall to barbed
tting on the outlet of the lter and secure with a
clamp.
11. Run the tubing to the waterfall and attach to a waterfall device if applicable. Burying
the tubing will produce the most natural look for your pond.
12. If the pressure lter unit is equipped with a UV
light make sure it is properly plugged into a GFCI
protected outlet. DO NOT operate the UV light until
the pump is running.
13. For units with UV, there is a connection at the
ballast to be made. Connect the 2-pin ttings by
aligning the ends properly and rmly pushing them
together. Secure by hand tightening the nut to
create a weatherproof seal. This connection is not
meant to be submersed but is good for outdoor
use.
14. Plug in the pump and UV. Observe the lter and
connections for any leaks.
15. Conceal your pressure lter and tubing with your choice of landscaping. Fake rocks
are a good option to hide the lter.
Operation Tips
Running the ltration system continuously is the best way to keep your pond looking its
best. Once installed the lter will take a few weeks to build up sucient nitrifying bacteria
in the system.
To maximize the lter’s performance and avoid ineectiveness or damage to the lter, be
sure to match the ow rate with the lter’s specications.
These lters are not to be used in the winter during freezing conditions. Be sure to
disconnect and drain the lter to store in a warmer location for the winter.
Step 8
Step 13

4
Cleaning or Replacing the Filter Pads.
When installed on a dirty pond, the foam pads will need to be cleaned more frequently
until the pond clears. As pond conditions stabilize, the time between cleanings will
increase. Pads are meant to be slightly dirty, there is no need to overclean them. If you
notice a decrease in water ow, the lter may need to be cleaned. Also, be sure to check
that the pump is not clogged. Replacing the pads should be done as they begin to show
signs of wear to maximize ltration capabilities.
1. For EC1300U with UV, be sure to turn this o or
unplug it before servicing. Unplug the pump before
opening lter.
2. Loosen the locking nuts that secure the tubing
connectors to the lter and remove them from
the
lid. Be sure not to lose the gaskets that seal the
connectors to the lter.
3. To access the pads and bio-balls for cleaning or
replacement, the top of the lter can be removed by
taking o the clamp. Start by sliding the locking wedge
to release tension.
4. T o remove the clamp completely depress the tab and
open the clamp wide enough to remove from the lter.
5. Carefully lift the lid o the tub. Be sure to not lose the
O-Ring that seals the lid and tub.
6. Filter pads can be removed and rinsed with clean water.
Replace with new pads if they are showing signs of
wear.
7. Bio-balls can be accessed by removing the plate at the
bottom. Bio-balls can be rinsed with pond water to get
larger debris from them, but do not overclean these. This
is where the benecial bacteria grow.
8. Replace items in reverse order and install the O-ring with
lid assembly back on lter body.
9. Secure the clamp around the lter by closing the clamp
rmly and sliding locking wedge into place for a tight
seal.
10. Reattach hose connections with gaskets and locking
nuts securely in place.
11. Plug in pump and UV. Observe the lter and check for
leaks.
Step 3
Step 4
Step 6

5
UV Lamp and Quartz Sleeve Replacement – EC1300U
For units with UV lights it is recommended that a new lamp be installed after 12 months of
use. While the light might still turn on, the eectiveness of the UV light diminishes over time.
A glow from the clear section on the top indicates that the UV light is in use. Quartz sleeves
are typically long lasting and only require replacement if they break or develop a leak due to
the age of the seals.
UV Lamp Replacement
1. Unplug the UV unit and the pump.
2. Remove the six screws from around the top of the lter.
Take care not to lose any of the screws during this
process.
3. Remove the circular retaining ring and the top cover.
4. Remove the two screws and the plastic retainer clip that
holds the cord in place.
5. Unscrew the clear plastic UV lamp connector nut and
carefully remove from housing.
6. Remove the old UV lamp.
7. Carefully remove the black stabilizing protector on the end
of the bulb.
8. Do not touch the new bulb with your ngers. The oil from
your skin can cause pre-mature failure of the lamp.
9. Hold the new 9 watt lamp with a glove or clean cloth and
plug into the UV housing. Transfer the black stabilizing
protector unit to the new lamp.
10. Carefully slide the new lamp into the sleeve and screw
the connector back into place.
11. Reattach the cord retainer clip with the two screws.
12. Line up the cord properly in the housing and replace the
top cover and circular retaining ring. Secure with the six
screws.
13. Return the unit back to service.
UV Quartz Sleeve Replacement
1. Unplug the UV unit and the pump.
2. Loosen the locking nut that secures the outlet tubing
connector to the lter and remove it from the lid. Be sure
not to lose the gaskets that seal the connector to the
lter.
3. Remove the six screws from around the top of the lter.
Take care not to lose any of the screws during this
process.
4. Remove the circular retaining ring and the top cover.
Step 2
Step 4
Step 5
Step 9

6
5. Remove the two screws and the plastic retainer clip that holds the cord in place.
6. Unscrew the clear plastic UV lamp connector nut and carefully remove from housing.
7. Carefully set the UV assembly aside being careful not to touch the UV lamp. If you are
replacing the UV lamp, follow the instructions above.
8. Gently pull straight up on the treaded connection in the middle and remove the UV housing.
9. Be sure to use caution as the quartz sleeve is glass and can break. If the sleeve is broken use
proper protection for your hands and eyes while cleaning glass from the lter.
10. To remove the sleeve from the UV housing, unscrew the top
tting. The glass section is secured to the top section and the
whole piece will be replaced.
11. Thread the new quartz sleeve assembly onto the UV housing.
12. Reuse the black end piece from the old sleeve and place on the
new sleeve.
13. Carefully replace the UV housing into the lter. Be sure it is
seated properly.
14. Replace the UV lamp assembly and screw it back in place being
careful not to touch the UV lamp.
15. Reattach the cord retainer clip with the two screws.
16. Line up the cord properly in the housing and replace the top cover and circular retaining
ring. Secure with the six screws.
17. Return the unit back to service.
Filter Specications
EC1300 EC1300U
Maximum Pond Size with Fish* (gallons) 650 650
Maximum Pond Size without Fish* (gallons) 1300 1300
UV/Watts n/a 9 Watts
Inlet/Outlet Sizes
1
/
2
",
3
/
4
", 1"
1
/
2
",
3
/
4
", 1"
Recommended maximum GPH 1300 1300
Volts / Frequency n/a 115 V / 60 Hz
Cord Length n/a 16 feet
*Fish load, amount of sunlight, etc. all aect actual maximum gallons ltered.
Step 10
15.47"
14.80" 12.24"

7
Coarse Pad
Fine Pad
Bio-Balls
Bottom Plate
O-Ring
Clamp
Part # Description
EC13UB 9 Watt UV Replacement Lamp
EC13US Replacement Quartz Sleeve Assembly
EC13BK Barb Hose Connector Set
(Includes 2 Connectors, 2 Nuts, 2 Gaskets)
EC13F Replacement Filter Pads
(Includes 1 Coarse Pad, 1 Fine Pad)
EC13L O-Ring - Seals Lid and Tub
EC13C Clamp - Secures Lid
9 Watt UV Lamp
Barb Hose
Connector
Locking
Nut
Retaining Ring
Lamp Connector
Cord Retainer Clip
Outlet Base &
UV Housing
Sleeve Top Fitting
Quartz Sleeve
Filter Lid
Exploded View
Replacement Parts
Troubleshooting
If there is no water through the lter to the pond…
• Check if the pump is on and working.
• Check if the pump is clogged and clear debris if needed.
• Check if the plumbing lines to and from the lter are blocked or loose/leaking.
continued...
Image for reference only

Troubleshooting cont.
If there is reduced ow through the lter...
• Check if pump is clogged and clear debris if needed.
• Check if lter pads are clogged and clean/replace if needed.
• Check if the plumbing lines to and from the lter are blocked or loose/leaking.
If the water is not clear…
• The lter may be new and requires a few weeks to “mature” with nitrifying bacteria.
• The lter may be the wrong size for the pond.
• The
pump may be the wrong size for the pond and lter. See specication chart or box for details.
• The UV lamp may be burned out or old. Replace if broken or after 12 months of use.
• The foam pads may need to be cleaned.
• The sh load and/or feeding rates may be too high.
If the lter is leaking…
• Check
that the gaskets and O-rings are seated properly and in good repair. Replace if needed.
• Check that the pump is properly sized for the lter.
• Check that the lter itself is not damaged or broken.
EasyPro Pond Products Limited Warranty
EasyPro Pond Products (“EasyPro”) warrants to the purchaser that this product ("Product") will be free from any
mechanical or material defects for a period of three years from the date of purchase.
UV bulbs, quartz sleeves, lter
pads and O-rings are considered wearable items and are not covered under this limited warranty
This warranty only covers properly installed and maintained Products sold by authorized EasyPro Sellers who are subject
to and follow EasyPro’s quality control standards. Please note that because EasyPro is unable to control the quality
of Products sold by unauthorized sellers, unless otherwise prohibited by law, this warranty does not cover Products
purchased from unauthorized sellers.
This warranty does not cover normal wear and tear, nor any deterioration suered through overloading, improper use,
negligence, improper installation, acts of God or accident. Similarly, any modication made by the purchaser to the
Product will cause the warranty to be null and void. This warranty does not cover any cost associated with the installation
or removal of the Product subject to a warranty claim.
All returned items will be inspected to determine cause of failure before a warranty claim is approved.
The exclusive remedies provided hereunder shall, upon EasyPro’s inspection and option, be either repair or replacement of
the Product or parts covered under this warranty.
Making a Claim: A Return Authorization (“RA”) number must rst be obtained by calling EasyPro at 800-448-3873 or
via email at [email protected]. It is the purchaser’s responsibility to pay the return shipping charges. Be sure to
include the RA number, original receipt (in the form of an invoice or sales receipt), your name, your return address and
your phone number inside of the package. No warranty claims will be honored without the original receipt that shows that
your purchase was made from an Authorized EasyPro Seller. Ensure the product is properly packaged and insured for the
replacement value. Damage due to improper packaging is the responsibility of the sender.
ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING MERCHANTABILITY OF FITNESS FOR A PARTICULAR
PURPOSE ARE HEREBY LIMITED IN DURATION TO THE DURATION OF THE WARRANTY AS DESCRIBED ABOVE. Some
States do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
EasyPro shall not be held liable for any damages caused by defective components or materials of this Product; or for
loss incurred because of the interruption of service; or any consequential/incidental damages and expenses arising from
the production, sale, use or misuse of this Product. Some States do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.
EasyPro shall not be held liable for any loss of sh, plants or any other livestock as a result of any failure or defect of this
Product. This warranty gives you specic legal rights, and you may also have other rights that vary from State to State.
800-448-3873 • Grant, Michigan
www.easypro.com • [email protected]
6344 • 10/20
A4