EAW KF730P User manual

EasternAcoustic Works One Main Street Whitinsville, MA01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RDxxxx (A) KF730P SPEC Preliminary March 2004
KF730P Specifications group · M
FEATURES
• Highest output to size ratio for small format line arrays
• Large MF/HF horn and PhaseAligned™ LF drivers for
exceptional 110° horizontal pattern to 160 Hz
• KF730 Wizard auto-designs flown and ground-stacked arrays
•IncludedSplayBracketsfixthesplayanglesbetween enclosures
•16ohminputsallowpowering 8KF730swith2 amplifierchannels
DESCRIPTION
The KF730P Series is a compact, fixed installation, line array
systemthatsetsaperformancebenchmarkabovesimilarsystems.
Itdelivers3-way, KF Series performance in a flexible,easy-to-use
system that can deliver concert-level output in an exceptionally
widerangeofvenues.TheKF730Pisanexcellentsolutionforfixed
installationapplications such as houses of worship, theatres,hotel
ballrooms, arenas, and concert halls. The system is also ideal for
supplemental coverage for larger line arrays, such as the KF760
Series. Such uses include audience side fill, delayed arrays for
balconies,andstage/performercoverage.
OnelargeMF/HFhornfillstheentirefaceoftheenclosure,better
maintaining horizontal pattern control throughout the MF/HF
passband. The curved aperture MF loading slots effectively
move the MF acoustic origin further into the horn than physical
space permits. The side-mounted LF drivers provide a forward-
firing, figure eight type pattern. The drivers are spaced so that
theLF beamwidthmatchesthe MFthroughcrossover.
The KF730P input features barrier strip terminals. A separate
terminal strip is provided for loop-through connection for daisy-
chaining additional KF730Ps. The KF730P is configured using
the included KF730P Splay Angle Brackets to bolt the
enclosurestogether. Thisriggingsystemisfullycompatiblewith
thecompanionSB730Psubwoofer.Six yearwarranty.
3-WAY FULL-RANGE BI-AMP(passive MF/HF filter)
Performance is for a single KF730P.Array performance is determined using the KF730 Wizard.
See TABULAR DATAnotes for details
CONFIGURATION
Subsystem Transducer Loading
LF 2x10 incone PhaseAligned™
MF 2x 7in cone Horn-loaded
HF 2x 1in exit,1.75 in voice Horn-loaded
coilneodymium
compressiondriver
Operating Mode Amplifier Channels External Signal Processing
Bi-amp LF,MF/HF DSPw/2-wayfilters
PERFORMANCE 1
Operating Range 80Hz to20 kHz
Nominal Beamwidth
Horz 110°
Vert 12°
Axial Sensitivity (wholespaceSPL)
MF/HF 105dB 230Hz to20 kHz
LF 91dB 80Hz to230 Hz
Peak Sensitivity (wholespaceSPL)
MF/HF 112 dB 20Hz to20 kHz
LF 92dB 20Hz to20 kHz
Input Impedance (ohms)
Nominal Minimum
MF/HF 16 15.9@ 680Hz
LF 16 15.1@ 250Hz
Recommended High Pass Filter
HighPass =>80 Hz,24 dB/octave
Accelerated Life Test 2
MF/HF 75V 350W @16 ohm
LF 106V 700W @16 ohm
CalculatedAxial Output Limit (whole spaceSPL)
Average Peak
MF/HF 130dB 136dB
LF 119 dB 125dB
ORDERING DATA
Description Part Number
KF730P Black LineArray Loudspeaker 0007663
KF730P White LineArray Loudspeaker 0009645
OptionalAccessories
KF730P/SB730PFly-Bar 0008108
KF730PPull-Bar 0008363
1To achievespecified performance,the listedexternal signalprocessing withEAW-provided settings is required.
2Forrecommendations toselect poweramplifier sizerefer to: “HOW MUCHAMPLIFIERPOWERDO INEED?” onthe EAW web site.

EasternAcoustic Works One Main Street Whitinsville, MA01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RDxxxx (A) KF730P Preliminary March 2004
KF730P Specifications group · M
ENCLOSURE
Material Balticbirch plywood
Finish Wearresistanttexturedblack paint
Grille Powder-coatedperforated steel
1.59
7.66
12.10
15.19
12°
6.00
RIGHT SIDE
DIMENSIONS APPLY TO BOTH SIDES
NOTES:
1. SYMBOL INDICATES MOUNTING POINT,
3/8-16 THREADED HOLE (PI ANGLE) .
2. SYMBOL INDICATES MOUNTING POINT,
3/8-16 THREADED HOLE (STRAPPING).
3. SYMBOL INDICATES CENTER OF BALANCE.
4. WEIGHT APPROX. 78 LB.
5. SHIPPING WEIGHT APPROX. 86 LB.
GRILLE PARTIALLY SHOWN
FRONT
13.03 10.23 7.23 C
L
24.72
28.75
(2.01)
DIMENSIONS APPLY TO
TOP AND BOTTOM
VIEW A-A
8.25
C
L
12.17
1.73
AACCESS PANEL
A
PRODUCTION
2X HANDLE
(9.83)
7.69
4.69 C
L
EASTERN ACOUSTIC WORKS
2.42
INPUT
5.00
9.134.00
C
L
BACK
KF730P

EasternAcoustic Works One Main Street Whitinsville, MA01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RDxxxx (A) KF730P Preliminary March 2004
KF730P Specifications group · M
PERFORMANCE DATA See NOTES GRAPHIC DATA Notes for details
Frequency Response: Processed Bi-amplified
LF = green MF/HF = orange Complete = blue
SPL(dB)
Frequency Response: Unprocessed
LF = green MF/HF = orange
SPL(dB)
Frequency Response: Digital Signal Processor
LF = green MF/HF = orange
dB re 0.775 V
Beamwidth (-6 dB SPL Points)
Horizontal = orange Vertical = black
Degrees
Impedance Magnitude
LF = green MF/HF = orange
Ohms
120
110
100
90
80
70
60
100
10
1
400
100
10
1100 1000 20000
Frequency(Hz)
10 100 1000 20000
Frequency (Hz)
120
110
100
90
80
70
60
20
10
0
-10
-20
-30
-40
10 100 1000 20000
Frequency (Hz)
10 100 1000 20000
Frequency (Hz)
10 100 1000 20000
Frequency (Hz)
120
110
100
90
80
70
60 10 100 1000 20000
Frequency (Hz)

EasternAcoustic Works One Main Street Whitinsville, MA01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RDxxxx (A) KF730P Preliminary March 2004
KF730P Specifications group · M
INPUT PANEL
WHITINSVILLE, MA USA S/N
-- +-- +
-- +-- +
LF MF/HF
LF MF/HF
LOOP THRU
Before suspending, read all rigging warnings in the Owner's Manual.
DANGER
KF730P
NOTES
TABULARDATA
1. PrimaryMeasurement/DataProcessingSystem: FChart:proprietary EAWsoftware.
2. SecondaryMeasurement System: Brüel &Kjær2012.
3. MicrophoneSystems: EarthworksM30; Brüel&Kjær 4133
4. Measurements: DualchannelFFT;length: 32768samples; sample rate:48kHz; logarithmicsinewave sweep.
5.Measurement System Qualification(includesall uncertainties):SPL: accuracy +/-0.2dB@ 1kHz,precision +/-0.5 dB20Hz to20kHz, resolution 0.05dB;Frequency: accuracy+/-1%,
precision+/-0.1Hz, resolutionthelarger of 1.5Hzor 1/48octave;Time:accuracy+/-10.4 µs,precision+/-0.5 µs, resolution10.4µs;Angular:accuracy+/-1°, precision +/-1°,resolution1°.
6. Environment: Measurementstime-windowedandprocessedtoeliminate roomeffects,approximatingananechoicenvironment.Dataprocessedasanechoic orfractionalspace,asnoted.
7. MeasurementDistance: 7.6to8.0m. Datais referencedtoother distances using theInverseSquare Law.
8. Volts: Measuredrmsvalue ofthetest signal.
9. Watts: Peraudioindustrypractice, “loudspeakerwatts”arecalculated as voltagesquareddividedby ratednominalimpedance. Thus, thesearenotTrueWattunitsof energyasdefined by
InternationalStandard.
10. SPL: (SoundPressureLevel) Equivalenttothe average levelofa signalreferencedto 0 dBSPL=20microPascals.
11.Subsystem: Thisliststhe transducer(s)andtheiracoustic loadingforeach passband. Sub Bass=Subwoofer,LF=Low Frequency,MF =MidFrequency,HF= HighFrequency.
12.Operating Mode: User selectableconfigurations.Betweensystemelements,acomma(,)= separateamplifierchannels;a slash (/) =singleamplifierchannel.DSP=DigitalSignalProcessor.
IMPORTANT:Toachievethespecified performance,thelisted external signalprocessingmust beusedwith EAW-providedsettings.
13.Operating Range: Range wheretheprocessed Frequency Responsestayswithin-10 dBSPLofthepoweraveraged SPLwithinthisrange;measuredon thegeometricaxis. Narrow band
dipsareexcepted.
14.Nominal Beamwidth: Designanglefor the-6dB SPLpoints,referencedto 0dBSPLasthehighest level.
15.AxialSensitivity: PoweraveragedSPLovertheOperating Rangewithan input voltagethatwouldproduce 1Wat the nominalimpedance;measured withnoexternal processing onthe
geometricaxis,referenced to1m.
16.Peak Sensitivity: HighestaxialSPLmeasuredwithinthe 20Hzto 20 kHzbandpasswithaninput voltagethatwouldproduce 1 Watthe nominal impedance;measured with noexternal
processingonthe geometricaxis,referenced to 1m.
17.Nominal Impedance: Selected 4,8,or 16 ohmresistancesuchthat theminimumimpedance point isnomore than20%below this resistanceovertheOperating Range.
18.AcceleratedLifeTest: Maximumtestinputvoltageapplied withanEIA-426B defined spectrum;measuredwith recommendedsignalprocessing and RecommendedProtectionFilter.
19.CalculatedAxialOutput Limit: Highest average andpeakSPLs possibleduringtheAcceleratedLifeTest. ThePeak SPLrepresentsthe2:1 (6dB)crest factor oftheLifeTest signal.
20.Recommended High PassFilter: Thisshould be usedtohelp protecttheloudspeaker from excessiveinputsignal levelsbelowthe Operating Range.
GRAPHICDATA
1.Resolution:To removeinsignificantfinedetails,1/12 octavecepstralsmoothingwasapplied to acousticfrequencyresponse and1/3octavecepstralsmoothing wasappliedto the
beamwidthandimpedancedata. Othergraphs areplottedusing raw data.
2.Frequency Responses: The variationinacoustic output levelwithfrequency foraconstantinputsignal of2volts(4 ohm nominalimpedance),2.83 volts(8ohmnominal impedance),
or4volts(16 ohmnominalimpedance) referenced toadistanceof 1m.For processed systems,thisapplies wheretheprocessor gain is0dB intheProcessor Frequency Responsegraph.
3.Processor Response: The variationinoutput level withfrequencyfor aconstantinputsignalof 0.775V= 0 dBreference.
4.Beamwidth:Averageangleforeach 1/3octavefrequencyband where, startingfromtherear oftheloudspeaker,the outputfirstreaches -6 dBSPLreferencedto0 dB SPLas thehighest
level.Thismethodmeans theoutputmay drop below-6dB SPLwithin the beamwidthangle.Referencedto 20m.
5.Impedance: Variationin impedance magnitude,inohms, withfrequencywithout regard tovoltage/currentphase.Thismeans the impedancevalues may not
beusedto calculateTrueWatts(see 9above).
DSP
EQ
DELAY
HPF/LPF
3-Way, Bi-Amp (LF, MF/HF)
AMP
HF
XVR
LF
MF
AMP
SIGNAL DIAGRAM
LEGEND
DSP: User-supplied Digital Signal Processor for EQ, crossover, and delay.
HPF: High Pass Filter for crossover or Recommended High Pass Filter.
LPF: Low Pass Filter for crossover.
LF/MF/HF: Low Frequency / Mid Frequency / High Frequency.
PWRAMP: User-supplied PowerAmplifier.
XVR: Passive LPFs, HPFs, and EQ integral to the loudspeaker.
Table of contents
Other EAW Amplifier manuals

EAW
EAW POWER AMPLIFIER CXA120 User manual

EAW
EAW CAM80 User manual

EAW
EAW Commercial CXA160 User manual

EAW
EAW UXA4403 User manual

EAW
EAW UXA4401 User manual

EAW
EAW UXA4406 series User manual

EAW
EAW CAZ1400 User manual

EAW
EAW Commercial CXA 80 User manual

EAW
EAW CAZ1400 User manual

EAW
EAW UXA4403 User manual