Option B – ventilation through the roof
Prior to installation of the Installation Kit and Connection Kit are
needed. These can be purchased from the place where the toilet was
bought.
1. Lift the upper section (5) of the toilet, remove the urine
container (8) and waste container (3)
2. Fasten the wallbracket temporairly on the lower section (7),
put the the lower sektion in posision aginst the wall. Mark for
the bracket.
3. Remove the wallbracket from the toilet. Install the bracket on
the wall.
4. Put the 90 degrees bend on the outlet.Set the lower section
in position and fasten it to the wallbracket.
5. Make a hole in the roof for the ventilation pipe, 55 mm.
6. Install the ventilation pipes unsleeved end into the 90 degrees
coupling.
7. Insulate all piping that passes through cold spaces (e.g. in the
attic and on above roof). This is to prevent condensation.
8. Cut the exterior pipe to t the angle of the roof.
9. Position the roof ashing. For tin roof, its better to have a
sheetmetal worker to make the ashing.
10. Put the outer pipe with the roof ashing over the insulated
ventilation pipe.
11. Adjust the roof ashing to the external roof and seal rmly
with asphalt sealant between the ashing and the roof.
12. Once all the piping is insulated and covered, t the reducing
coupling on top, and then t the insect netting.
13. Place a bag in the composting chamber and fold it over the
edge. Put the frame in position to lock the bag. bag. Place the
container inside the lower section and make sure that the bag
does not cover the fan.
14. Put back the top.
15. Connect to power.