manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. EdgeStar
  6. •
  7. Kegerator
  8. •
  9. EdgeStar KC3000 User manual

EdgeStar KC3000 User manual

KC3000 Kegerator Installation Guide
1. Faucet Handle
2. Faucet
3. Beer Tower
4. Guard Rail
5. Drip Tray
6. Regulator
7. CO2Tube
8. CO2 Cylinder (supplied empty)
9. Cylinder Clip
10. American Sankey Keg Coupler
11. Metal Keg Floor Support
12. Casters (x4) and Washers (x2)
13. Beer Line
14. Half Barrel Keg (not included)
15. Neoprene Washer
16. Hose Clamps (2)
17. Tower Plug
18. Long Bolt and Nut
19. Tower Gasket
20. Screws (4)
Tools Needed:
- Wrench
- Flat Head Screwdriver
- Pair of Pliers/Clamp Crimper
15
16
17
18
19
20
14
1
2
3
4
5
6
7
8
9
10
11
12
13
For additional information
visit edgestar.com
Warning:
CO2can be dangerous! CO2cylinders contain high-pressured gas, which can be hazardous if handled improperly. Please handle with care.
12
34
5 6
Before assembly, make
sure to empty the inside
of the unit including all
shelves and metal keg
floor (# 11). Carefully
lay the unit on its back.
Attach the casters (#12)
into the existing holes at
the bottom of the unit.
The front two casters
require a flat washer
(part# 12) prior to
installation. Next, set
the unit upright and
reinstall the keg floor
(# 11).
Note: Allow the dispenser
to stand in an upright
position for 24 hours
before plugging in the
unit.
Install Caster Wheels Remove Plug
Install Tower Secure Tower
Install Railing
Carefully remove the
tower plug (#17)
located on the top of
the unit by opening the
cabinet, and with your
hand, push plug
through the top of the
cabinet from the inside.
Use flat head screw-
driver as a prying tool if
necessary.
Mount the tower gasket
(#19) by lining it up with
the preexisting holes at
the top of the unit.
Install the tower (#3) by
first unraveling the beer
line from the bottom of
the tower. Feed the beer
line (#13) through the
top opening that was
under the cabinet plug.
Once the beer line is fed into the
unit line up the holes at the
bottom of the tower and install
the four screws (#20).
Take the railing (#4) and
slide its “feet” into the
pilot holes in the top of
the cabinet.
Install Handle & Faucet
Screw the faucet
handle (#1) to the beer
faucet (#2). Line up
the beer faucet to the
tower shank at the
front of the tower (#3)
and tighten the collar.
Note:
This manual is intended as a guide for installation.
While there are many different ways to install this kit, we recommend you follow these instructions.
If you are uncomfortable in your ability to assemble this kit, seek professional assistance.
Attach the CO2regulator (#6) to
the CO2cylinder (#8) by
screwing the regulator nut onto
the cylinder valve and tightening
with pliers.
Note: A fiber washer is normally
required to connect a regulator to
a CO2cylinder, but the standard
regulator provided includes a
built-in o-ring.
Make sure the shut off
valve at the bottom of the
regulator is closed (9
o’clock position). Install
the CO2Tube (#7) to the
hose barb at the bottom of
the regulator (#6) and
secure with a hose clamp
(#16).
Mount the CO2cylinder (#8) onto
the step and inside the cylinder
clip (#9). Secure the tank into
the clip using the long bolt and
nut (#18).
Attach the remaining
end of the CO2tube
(#7) to hose barb on
the side of the coupler
(#10). Secure the tube
with a hose clamp
(#16).
Now connect the beer line
(#13) to the keg coupler
(#10). Insert the neoprene
washer (#15) into the
beer line hex nut (the beer
line is the line coming
from/going to the tower
and faucet). Remove the
blue rubber protective cap
located on top of the keg
coupler and screw the nut
with the rubber washer to
the top of the keg coupler,
hand-tighten firmly.
Connect Regulator to Cylinder Connect Tube to Regulator
Mount CO2Cylinder Attach Tube to Coupler
Connect Beer Line
To connect the keg coupler
(#10) to the keg (#14),
first make sure the black
pull handle of the keg
coupler is in the up position
(45° angle). Insert the keg
coupler into the valve on
top of the keg and turn
clockwise until it stops
about 90° to lock the
coupler into place. Now pull
the tap handle out (away
from the keg coupler (#10)
and push down until it
locks into position. Listen
for the “click” of the pull
handle when it shifts into
the final downward
position. The keg is now
tapped.
Connect Keg Coupler
78
910
11 12
Warning:
This guide is provided for informational purposes only. It is provided as a supplement to the owner’s manual.
Please refer to the owner’s manual for a full discourse on installation, usage and maintenance. If you have any questions about the installation of
this appliance, feel free to contact EdgeStar service at 866.319.5473 or consult a qualified installer. Neither the manufacturer nor its distributors
shall be liable for any incidental, consequential, indirect, special, or punitive damages of any nature, including without limitation, lost revenues or
profits, or any other damage whether based in contract, tort, or otherwise.
Co2 cylinder comes empty due to HAZMAT restrictions. It will need to be filled locally at any air/gas
supplier prior to use.
13 Calibrating the Regulator
(A) With the shut-off valve on the regulator closed, open the valve on the CO2 cylinder (#8) completely.
(B) With a pair of pliers, loosen adjustment nut allowing adjustment screw to be turned counter-clockwise until adjustment screw is completely open.
(C) Using a flathead screwdriver, slowly turn the regulator adjustment screw clockwise until the desired pressure is shown on the pressure gauge on the top. By turning
the screw clockwise it will increase (+) pressure and counterclockwise will decrease (-) pressure. Under normal circumstances, we recommend setting the regulator at
10-12psi. NOTE: When adjusting pressure from a high pressure to a lower pressure, you will need to release the higher pressure out by pulling the manual pressure
release valve ring located on the side of the coupler.
(D) Once the desired pressure is set, open the shut-off valve by turning the lever down (6 o’clock position or parallel to the CO2 tube). Gas should now be flowing from
the regulator to the keg coupler. You will hear the keg pressurizing. The output needle will drop momentarily while the pressure is equalizing. Then, the needle will
return to the point you set it at.
NOTE: Other conditions, such as altitude, beer type, and temperature may require some adjustment. It is always wise to follow up any adjustment to the regulator
with a brief pull of the pressure release valve ring on the regulator or coupler to ensure an accurate output reading.
Multiple Keg Configurations
ON
OFF
AB C D
CO2 LINE
BEER LINE
CO2 LINE
BEER LINE
For twin tap models For triple tap models
*Manifold included in triple tap models

Other EdgeStar Kegerator manuals

EdgeStar ECK24 User manual

EdgeStar

EdgeStar ECK24 User manual

EdgeStar BR2001BL User manual

EdgeStar

EdgeStar BR2001BL User manual

EdgeStar BR1500BL User manual

EdgeStar

EdgeStar BR1500BL User manual

EdgeStar BR7000SS User manual

EdgeStar

EdgeStar BR7000SS User manual

EdgeStar BR7001SS User manual

EdgeStar

EdgeStar BR7001SS User manual

EdgeStar BR1500SS User manual

EdgeStar

EdgeStar BR1500SS User manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.