EKM 15IDS-N User manual

Load
current
Power
factor
COS
Basic error%
Basic error%
Load
current
Power
factor
COS
Class 0.5 Class 1
0.05Ib
1.0
±1.0
±1.5
0.1Ib~Imax
1.0
±0.5
±1.0
0.1Ib
0.5(L)
±1.0
±1.5
0.1Ib
0.8(C)
±1.0
±1.5
0.2Ib~Imax
0.5(L)
±0.5
±1.0
0.2Ib~Imax
0.8(C)
±0.5
±1.0
METERING SOLUTIONS FOR FOR A MORE EFFICIENT FUTURE.
EKM METERING
EKM METERING http://ekmmetering.com – (831)425-7371 – [email protected]
EKM-15IDS and EKM-15IDS-N Spec Sheet
Use these meters for accurately measuring 120 volt 2-wire loads
Use if you have easy access to your wires, and if you wires are under
3/8” in diameter. For larger amperages and wire sizes use our
EKM-Omnimeter.
Single Phase 120 volt 2-wire, 50amp, DIN Rail Mount
Nominal Voltage Ranges:
120 volt , 2-wire, Single-phase, 1 Hot and 1 Neutral
Range of allowable environmental conditions: Pollution Degree 2,
Measurement Category III, Altitude rating 2000 meters max.
Maximum Temperature Range: -30 Deg. C to 70 Deg. C. Tamper
Detection Class 1.
The equipment is protected throughout
by double insulation as indicated by:
Safety Precautions
•Meter should be installed by a qualified electrician.
•Turn off all power supplying the equipment before perform-
ing any wiring operations. Use a properly rated volt meter to confirm
power is off.
•Use of this device inconsistent with this manual can cause
permanent damage to the unit and/or serious harm to the operator.
Tools/Materials List
•Volt meter
•Small standard screwdriver
•Wire stripper
•DIN-Rail
•16-22 AWG UL rated stranded copper wire
Specs:
1. Rated voltage: 120V 2-wire (1 Lines, 1 Neutral)
2. Rated current: 5(50)A
3. Pulse Output:800imp/kWh
4. Rated frequency: 60Hz
5. Class of Accuracy: 1.0
6. Start current: 0.4%Ib(1.0)
7. Creep: logical design of Anti-creep
8. Power consumption: ≤1W(when 120V)
9. Temperature -20—45°C
Max. limit work temperature -30—55°C
relative humidity ≤85%
10. Weight:12.8oz.or0.32kg
11. Outside dimensions:78×100×65mm
Installation Instructions
For All Systems
1. Disconnect or switch power off before attempting to install,
connect, disconnect or service the meter. ALL POWER MUST BE
DISCONNECTED!
2. Mount the meter using 35mm DIN Rail in a protected indoor
location; an enclosure is always recommended.
3. IMPORTANT: Distinguish and then identify the Neutral and the
Line(s) (‘hot’ wire(s), usually black or red). Label the Neutral and
then, depending on your electrical system, assign labels as
described below.
120V, Single Phase, 2-Wire
Wiring Diagram 1: for EKM-15IDS
1. Label hot line - “L” and Neutral - “N”.
2. Pass the L stranded copper wire through the L port (the tube in
the body of the meter. Pass the N stranded copper wire through
EKM METERING http://ekmmetering.com – (831)425-7371 – [email protected]
the N port in the meter. If the wire will fit through the provided
centering bushings, then the bushings should be used. These
wires should be passed so that the power flows from bottom of
meter (source side) to the top of the meter (load side). The Neutral
wire will bypass the meter.
3. Tighten down the L wire tap and the N wire tap.
4.Secure the terminal block cover.
Wiring Diagram 2: for EKM-15IDS-N
Both EKM-15IDS and EKM-15IDS-N have 7 digits. Displayed as
99999.99
They also have a pulse output of 800 pulses per kWh
Communications:
For EKM-15IDS-N RS-485: Connect RS-485 A on meter to
RS-485 A on the communication converter. Connect RS-485 b on
meter to RS-485 b on the communication converter. Up to 256 of
these meters can be daisy chain connected to the meter network
on up to 4000 feet of wire.
For a lot more information on installation, communications, and
operation of these meters, please go to this page on the web:
http://www.ekmmetering.com/information/the-complete-guide.html
Warranty:
These meters come with a 2 year warranty.
CE Mark
IEC 62052-11
IEC 62053-21

This manual suits for next models

1

Other EKM Measuring Instrument manuals

EKM Omnimeter I User manual

EKM

EKM Omnimeter I User manual

EKM IENC User manual

EKM

EKM IENC User manual

EKM 15IDS User manual

EKM

EKM 15IDS User manual

EKM 25IDS-N User manual

EKM

EKM 25IDS-N User manual

Popular Measuring Instrument manuals by other brands

JAMAR Technologies DB-100 user manual

JAMAR Technologies

JAMAR Technologies DB-100 user manual

OHAUS 8000 Series user guide

OHAUS

OHAUS 8000 Series user guide

Teledyne Lecroy Frontline Sodera LE quick start guide

Teledyne Lecroy

Teledyne Lecroy Frontline Sodera LE quick start guide

Mohr CT100 Operator's manual

Mohr

Mohr CT100 Operator's manual

LaserLiner MoistureMaster Compact Plus manual

LaserLiner

LaserLiner MoistureMaster Compact Plus manual

Energybox Hub installation manual

Energybox

Energybox Hub installation manual

Benning CFlex 1 operating manual

Benning

Benning CFlex 1 operating manual

Spectra Precision Focus 10 user guide

Spectra Precision

Spectra Precision Focus 10 user guide

Casella 620 Series manual

Casella

Casella 620 Series manual

kruss DS7000 Series user manual

kruss

kruss DS7000 Series user manual

Tyre ?are T802C instruction manual

Tyre ?are

Tyre ?are T802C instruction manual

Hioki IM3523A Startup guide

Hioki

Hioki IM3523A Startup guide

ComSonics Companion user guide

ComSonics

ComSonics Companion user guide

Bante Instruments TB100 instruction manual

Bante Instruments

Bante Instruments TB100 instruction manual

Entes EVM-3 Quick user guide

Entes

Entes EVM-3 Quick user guide

Triplett CM450 user manual

Triplett

Triplett CM450 user manual

Anritsu MT1000A Network Master Pro Configuration guide

Anritsu

Anritsu MT1000A Network Master Pro Configuration guide

Trox Technik CAV controllers installation manual

Trox Technik

Trox Technik CAV controllers installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.