PRODUCT DATASHEET
2. PRODUCT DATA SHEETSHEET
2.1 JGF009 / VGF0092.1 JGF009 / VGF009
Model Indoor UnitModel Indoor Unit JGF009JGF009
Model Outdoor Unit VGF009
Installation Method of Pipe Flared
Characteristics Units Cooling Heating
Capacity (4) kW 2.64 2.81
Power input (4) kW 0.82 0.78
EER (Cooling) or COP(Heating) (4) W/W 3.21 3.61
Energy efficiency class A A
V 220-240
Ph 1
Power supply
Hz 50
Rated current A 3.8 3.6
Power factor 0.92 0.92
Prated (IDU+ODU) W 1120
Circuit breaker rating A 10A
Fan type & quantity Crossflow x 1
Cooling SH/H/M/L RPM 1390/1280/1180/1080
Fan speeds Heating SH/H/M/L RPM 1350/1250/1140/1040
Air flow (1) SH/H/M/L M3/hr 400/370/340/310
External static pressure Min Pa 0
Sound power level (2) SH/H/M/L dB(A) 50/47/45/42
Sound pressure level(3) SH/H/M/L dB(A) 40/37/35/32
Moisture removal l/hr 1.0
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 730x255x174
Net Weight kg 8
Package dimensions WxHxD mm 790x325x245
INDOOR
Packaged weight kg 10.5
Refrigerant control Capillary
Compressor type, model Rotary, Panasonic-5PS102EAA22
Fan type & quantity Propeller(direct) x 1
Fan speeds H RPM 830
Air flow H M3/hr 1500
Sound power level H dB(A) 60
Sound pressure level(3) H dB(A) 50
Dimensions WxHxD mm 785x540x320
Net Weight kg 31
Package dimensions WxHxD mm 820x580x355
Packaged weight kg 34
Refrigerant type R410A
Standard charge kg(4m) 0.76
Additional charge g/m 30g/m(4m<L<15m)
Liquid line In.(mm) 1/4"(6.35)
Suction line In.(mm) 3/8"(9.53)
Max.tubing length m. Max. 15
OUTDOOR
Connections
between units
Max.height difference m. Max. 10
Operation control type Remote control
(1)Airflow in ducted units; at nominal external static pressure.
(2)Sound power in ducted units is measured at air discharge.
(3)Sound pressure level measured at 1-meter distance from unit.
(4)Rating conditions in accordance to ISO 5151 and ISO 13253 (for ducted units).
SM JGF 1-A.1 GB 2-1