Electra Touch Line Series User manual

4 Wires
1/2/3 Families
VIDEO DOOR PHONE KIT 3.5”/7”
User manual
EN

KIT INSTALLATION. Follow the steps below, in the described order.
STEP 1. Read the diagrams in this brochure and the technical manuals of the KIT (VPM, VTx, SCU).
STEP 2. Make the electrical connections to the terminals (ATM, VTM, VTE) and then to the VPM outdoor panel.
STEP 3. Make the electrical connections of the LCK door lock and LOCK SUPPLY to the terminals of the SCU central unit
and, if necessary, the connections to: the EXIT button; AUX additional installations; BAT; Vcam analog video camera.
STEP 4. AUTHORIZED PERSONNEL!!! READ THE SAFETY INSTRUCTIONS FROM THE MANUAL OF THE SCU CENTRAL
SUPPLY UNIT!!! DISCONNECT the fuses and make the L,N, connections to the SCU CONNECT the fuses to the
power network. The , S2 LEDs turn on, and S1 turns on only if the battery (12V/max. 42Ah) is connected.
STEP 5.1. PROGRAMMING THE MAIN ENTRANCE PANEL: RFID CARDS/TAGs At the SCU, long press (2-3 sec.) the PROG
button (point 6). The PROG Red LED turns on Go to the VPM panel from the main entrance and touch each
RFID CARD to the (RFID) area for one second. For each programmed RFID CARD/TAG, the panel issues
two beeps. Follow the same steps for programming all the RFID CARDS/TAGs, for all the residents of the building
Return to the SCU and short press the PROG button. The Red LED turns off. The main panel keeps address 1, which
is set from the factory and is ready to function.
STEP 5.2. PROGRAMMING THE ADDITIONAL PANEL: NEW ADDRESS and RFID CARDS/TAGs. If the access in the building is
made through two entrances, the VPM2 additional panel (point 11) from entrance 2 must be set up with address 2.
At SCU 2 long press the PROG button. The PROG Red LED turns on. At the VPM2 panel, long touch the Fam.1 key
(long confirmation beep), then short touch the Fam.1 key, twice. The panel confirms the storage of address 2 with
two short beeps. Continue programming the CARDS/TAGs in the VPM2 panel. Each touch of the CARD/TAG to the area is
confirmed by the VPM2 with two beeps. Return to the SCU2 and short press the PROG button. The Red LED turns off.
The VPM2 and VPM1 panels are ready to function, with all the terminals in the building.
STEP 6.1 PROGRAMMING THE ADDRESS OF THE Fam.1 TERMINAL. The terminals keep Address 1, which is set by the
manufacturer.
STEP 6.2 PROGRAMMING THE ADDRESS OF THE Fam.2, Fam.3 or more TERMINALS. The terminals for Family 2 will have
address 2, the terminals for Family 3 will have address 3 and so on for 4, 5 etc.
Program the new addresses as follows: At SCU 1 long press (3 sec.) the PROG button. The PROG Red LED turns on
At the terminals for Family 2, long touch the key. The terminal confirms with one long beep. Short touch the
key twice. Two short beeps are issued. The terminal stores address 2. Continue programming address 3 at Family 3 following
the same steps. Long touch the key and after the long beep, short touch the key three times. Storage is confirmed
with three short beeps. Return to the SCU and short press the PROG button. The Red LED turns off. The terminals are ready
to function.
RECOMMENDED CABLES (point 1, pg. 15) Maintain the same wire colors for the same connections.
2
Out of electrical safety reasons, we recommend installing a grounding cable (minimum 1.00 mm – Green/Yellow) from the
panel (VPM) to the central unit (SCU).
1
DETAILED PRODUCT CODES
VPM - smart video outdoor panel; Product codes: 1Fam.VPM.1S(F)R02.xxy04; 2Fam.VPM.2S(F)R02.xxy04;
3Fam.VPM.3S(F)R02.xxy04; 5Fam.VPM.5S(F)R02.xxy04 (S= Surface mounting, F= Flush mounting, R= RFID CARD/TAG access)
RFID access CARD/TAG (secured at reading and copying). They are stored and can be deleted from the VPM.
ATM - smart+ audio terminal; Product code: ATM.0S402.xxy04
VTM - smart+ 3.5” video terminal; Product code: VTM.3S402.xxy04
VTM/VTE - smart+/extra 7” video terminal; Product codes: VTM.7S402.xxy04/ VTE.7S902.xxy04
VCB – Video connection box (1 video input/4 video outputs - 4 Fam.); Product code: VCB.4DN02.xxy04
EN
INSTALLATION INSTRUCTIONS – VIDEO DOOR PHONE KIT
Thank you for choosing the ELECTRA products. We will assist you throughout the entire warranty period.
For technical support and assistance you can contact us at ELECTRA Building Communications GmbH,
+43 1 810 20 99, sales@electra-automation.at.
2
1) Max. 75 ml 4 x 0.5 mm (H03VV-F4G 0.5)
2
2) Max. 150 ml 4 x 0.75 mm (H05VV-F4G 0.75)
3) Max. 250 ml UTP cat5e (AWG24) or UTP cat6e (AWG23)

EN
VSB – Video selection box; Product code: VSB.4DN02.xxy04 (4 video inputs/1 video output)
SCU – Central supply unit for 1 Fam; Product code: SCU.VDR02.xxy14 (110-230 Va.c., 50 Hz / 13,5 Vd.c.-2 Ad.c.).
Central supply unit for 3 Fam; Product code: SCU.VDR02.xxy34 (110-230 Va.c., 50 Hz / 13,5 Vd.c.-2 Ad.c.).
PSU – Additional supply unit; Product code: PSU.VDR02.xxy04 (110-230 Va.c., 50 Hz / 13,5 Vd.c.-2 Ad.c.), necessary when,
due to various reasons, the supply voltage (+U, GND) at the hubs of the terminals drops below 12V.
Vcam – Additional video camera connection, analogic 1Vv-v, PAL
LCK/LCK – Connection of an alternating current lock (max.5Aa.c./24Va.c.), a direct current lock (max.3Ad.c./24Vd.c.) or an
electromagnetic lock (max.3Ad.c./ 24Vd.c.)
LOCK SUPPLY – Connection of the door lock supply (max. 24 Va.c./24Vd.c.). A direct current lock of max. 0.6Ad.c./12Vd.c.
can be powered directly from the SCU by making the connections at the +U - GND connections of the VIDEO DOOR PANEL
connector.
NO/NC – Setting of the door lock functioning. NO-Normal Open - LCK relay normal open; NC-Normal Closed - LCK relay
normal closed.
EXIT/EXIT – Connection of EXIT button (mounted inside the building)
AUX1/AUX2 – Connection of additional installations – auto gate, garage door, outdoor lighting etc. (point 4)
+ BAT/- BAT – Connection of rechargeable battery
DBL1/DBL2 – Connection of entrance doorbell (apartment doorbell)
GONG1/GONG2 – Connection of distance call doorbell (GONG)
B.
1. Normal functioning mode, without BAT: the and +U LEDs are green. The PROG and BAT LEDs are turned off.
2. Normal functioning mode, with BAT connected: the , BAT and +U LEDs are green.
3. The system functions only on battery (the installation functions correctly until the full discharge of the battery): the
BAT LED is green, the and +U LEDs are turned off. Check the fuses on the SCU (FUSE T-1, 6A) and 2x6A from the network .
4. The system functions with a broken battery. The , +U LEDs are green, the BAT LED is turned off. Change the battery!
5. The outdoor panel does not function (the red LED from the outdoor panel does not blink, the call keys are not backlighted):
The , BAT and +U LEDs are green. At the SCU, the VIDEO DOOR PANEL LED is red. Check the continuity and the accuracy of
the +U and GND connections from the SCU to the panel.
6. A terminal does not function (the keys are not backlighted when touched, there is no image and sound): the , BAT and
+U LEDs are green. One of the OUT1, OUT2 or OUT3 LEDs is red. Check the continuity and accuracy of the +U or GND
connections from the SCU to the terminal.
7. The lock does not function (LCK, LCK): check the accuracy of the connections from the SCU to the lock.
8. The display of the terminal is blue (during call, the terminal is blue, there is sound): check the continuity and accuracy of the
Vin, Vout and GND connections from the outdoor panel to the video terminal.
9. The terminals are not called, the PROG LED is red: check the continuity and the accuracy of the C/D, +U and GND
connections from the outdoor panel to the video terminal.
10. The terminal for Family 2, Family 3 or with higher addresses cannot be called (The Family 1 terminal is always called):
reprogram the terminal with the correct address (the number of the apartment) according to the procedure in the user manual
of the terminal.
TROUBLESHOOTING AND SERVICE FOR THE VIDEO DOOR PHONE SYSTEM
PARALLEL CONNECTION OF TWO OUTDOOR PANELS (See the diagram from point 11)
If the building has multiple entrances, you can install VPM outdoor panels with their own SCU central supply unit, which will
command its own gate. The VPM1 main outdoor panel keeps address 1, set by the manufacturer and only the RFID access
cards/tags will be programmed at the VPM1 (see Step 5.1). The VPM2 additional panel is programmed with address 2 and
with the RFID access cards/tags (see Step 5.2).
PARALLEL CONNECTION OF THE ADDITIONAL TERMINALS (See the diagram from point 10)
Inside the residence you can install TL additional terminals (ATM/VTM 3.5”/ VTM 7”/ VTE 7”) using the same type
of cable, for the same connections (+U, C/D, GND, Vin/Vout). All the terminals in one apartment will have the
address of the main terminal. For Fam.1 the terminals have address 1 set by the producer. For Fam. 2, 3
(Fam. 4, 5 or more), program the terminals with addresses 2, 3 (or 4, 5 etc.). See Step 6.2.
2

2
+U
C/D
GND
Vin
+U
C/D
6mm
25-30mm
GND
Vout
6mm
25-30mm
2
1) Max. 75 ml 4 x 0.5 mm (H03VV-F4G 0.5)
2
2) Max. 150 ml 4 x 0.75 mm (H05VV-F4G 0.75)
3) Max. 250 ml UTP cat5e (AWG24)/UTP cat6e (AWG23)
3
1
EN
+U
C/D
GND
20-25mm
6mm
Vin
+U
C/D
GND
20-25mm
6mm
Vout
NF
AC 110/230V
EXIT
EXIT
LOCK
SUPPLY
==
LCK
LCK
DOOR LOCKS NF
AC 110/230V
FUSE-T1.6A
E307311
NO NC
2x6Aa.c.
N
L
max. 24 Va.c.
50Hz/60Hz
LCK
LCK
max. 24Va.c./5Aa.c.
110Va.c./230Va.c.
50Hz/60Hz
110Va.c./230Va.c.
50Hz/60Hz
max. 24 Va.c./5Aa.c.
50Hz/60Hz
NF
AC 110/230V
+U
C/D
GND
Vin1
VIDEO DOOR PANEL
6 A
VPMSCU

4
5
3
4
LED PROGPROG
SCU
NF
AC 110/230V
+U
C/D
GND
Vin1
VIDEO DOOR PANEL
EXIT
EXIT
LOCK
SUPPLY
==
LCK
LCK
DOOR LOCKS NF
AC 110/230V
FUSE-T1.6A
E307311
NO NC
max. 24Vd.c./3Ad.c.
2x6Aa.c.
N
L
max. 24 Vd.c. Electromagnet
110Va.c./230Va.c.
50Hz/60Hz
110Va.c./230Va.c.
50Hz/60Hz
max. 24 Vd.c.
max. 3 Ad.c.
!
+U
C/D
GND
Vin1
VIDEO DOOR PANEL
NF
AC 110/230V
6 A
3-5 sec.
max. 24V/1A(a.c./c.c.)
SCU
OTHER VIDEO
CAMERA(S)
Vin2
AUX1
AUX2
+BAT
VPMSCU
SCU
NF
AC 110/230V
EXIT
EXIT
LOCK
SUPPLY
==
LCK
LCK
DOOR LOCKS NF
AC 110/230V
FUSE-T1.6A
E307311
NO NC
2x6Aa.c.
N
L
max. 24 Vd.c.
50Hz/60Hz
LCK
LCK
max. 24Vd.c./3Ad.c.
110Va.c./230Va.c.
50Hz/60Hz
max. 24 Vd.c.
50Hz/60Hz =
110Va.c./230Va.c.
50Hz/60Hz
NF
AC 110/230V
+U
C/D
GND
Vin1
VIDEO DOOR PANEL
6 A
VPMSCU
SCU
EN
6

7
5
Vout2
GNV
GND
+U
VPM (Adr. 1)
Fam 1
Fam. 1
(Adr. 1)
GONG2
GONG1
DBL1
DBL2
Doorbell
+U
C/D
GND
Vin
GONG
SCU
+U
PROG
BAT 110/230V
OUT1
+U
C/D
GND
Vout
Vcam
EN
LCK
max. 24Va.c./24Vd.c.
EXIT
S1: 2x6Aa.c. 110Va.c./50Hz
230Va.c./50Hz
N
L
+U
C/D
GND
Vin
LOCK
SUPPLY
+U
C/D
GND
Vout
AUX
,
BAT
+
-
max. 42Ah/12V

6
8
Vout2
GNV
GND
+U
SCU
+U
PROG
BAT 110/230V
OUT1
Vcam
Fam. 2 (Adr. 2)
GONG2
GONG1
DBL1
DBL2
Doorbell
+U
C/D
GND
Vin
GONG
Fam. 1 (Adr. 1)
GONG2
GONG1
DBL1
DBL2
Doorbell
+U
C/D
GND
Vin
GONG
OUT2
+U
C/D
GND
Vout
+U
C/D
GND
Vout
VPM (Adr. 1)
Fam 2
EN
LCK
max. 24Va.c./24Vd.c.
EXIT
S1: 2x6Aa.c. 110Va.c./50Hz
230Va.c./50Hz
N
L
+U
C/D
GND
Vin
LOCK
SUPPLY
+U
C/D
GND
Vout
AUX
,
BAT
+
-
max. 42Ah/12V
Fam 1

9
7
+U
C/D
GND
Vin
GONG 2
GONG 1
DBL 1
DBL 2
Doorbell
GONG 2
GONG 1
DBL 1
DBL 2
Doorbell
+U
C/D
GND
Vin
Fam. 3
(Adr. 3)
Fam. 2
(Adr. 2)
GONG
GONG
Vout2
GNV
GND
+U
SCU
+U
PROG
BAT 110/230V
OUT1
+U
C/D
GND
Vout
Vcam
OUT2 OUT3
+U
C/D
GND
Vout
+U
C/D
GND
Vout
VPM (Adr. 1)
GONG 2
GONG 1
DBL 1
DBL 2
Doorbell
+U
C/D
GND
Vin
Fam. 1
(Adr. 1)
GONG
EN
AUX
,
BAT
+
-
max. 42Ah/12V
LCK
max. 24Va.c./24Vd.c.
EXIT
S1: 2x6Aa.c. 110Va.c./50Hz
230Va.c./50Hz
N
L
+U
C/D
GND
Vin
LOCK
SUPPLY
+U
C/D
GND
Vout
Fam 2
Fam 1
Fam 3

LCK
max. 24Va.c./24Vd.c.
EXIT
S1: 2x6Aa.c. 110Va.c./50Hz
230Va.c./50Hz
N
L
+U
C/D
GND
Vin
+U
C/D
GND
Vout
LOCK
SUPPLY
10
+U
C/D
GND
Vin
+U
C/D
GND
Vout
GONG
DOORBELL
DBL1
DBL2
GONG1
GONG2
VTM.7S402.xxy04/VTE.7S902.xxy04
VIDEO 7"
+U
C/D
GND
Vin
+U
C/D
GND
Vout
+U
C/D
GND
VIDEO 3.5"
VTM.3S402.xxy04
AUDIO
ATM.0S402.xxy04
11
8
VPM1
(Adr. 1)
1
VPM2
(Adr. 2)
2
Vout2
GNV
GND
+U
VPM (Adr. 1)
SCU
+U
PROG
BAT 110/230V
OUT1
+U
C/D
GND
Vout
AUX
,
Vcam
Vout2
GNV
GND
+U
SCU
+U
PROG
BAT 110/230V
OUT1
AUX
,
Vcam
VPM (Adr. 2)
VTM.7S402.xxy04/
VTE.7S902.xxy04/
VTM.3S402.xxy04/
ATM.0S402.xxy04
+U
C/D
GND
Vout
+U
C/D
GND
Vin
VSB
+U
C/D
GND
Vin
+U
C/D
GND
Vin
OUT
IN 1
IN 2
VCB
OUT 1
IN
OUT 2 OUT 3
OUT 4
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vout
OUT
Fam.1
Fam.2
Fam.3
IN 4IN 3
Fam 2
Fam 1
Fam 3
EN
+
-
max. 42Ah/12V
BAT
+
-
max. 42Ah/12V
BAT
LCK
max. 24Va.c./24Vd.c.
EXIT
S1: 2x6Aa.c. 110Va.c./50Hz
230Va.c./50Hz
N
L
+U
C/D
GND
Vin
+U
C/D
GND
Vout
LOCK
SUPPLY
+U
C/D
GND
Vout
Fam 2
Fam 1
Fam 3

12.2018 INS.VK3.ELY04
ELECTRA s.r.l
Bd. Chimiei nr.8, Iași - 700291 - RO
+40 232 214.370 +40 232 232.830
www.electra.ro
Certificate no. E307311
ISO 9001:2015
ISO 14001:2015
Certificates no. 73 100 4856, 73 104 4856
by TÜV HESSEN
The products are manufactured under
Quality and Environment Management System
R
The products contain UL-compliant
printed circuit boards.
ELECTRA is a trademark of ELECTRA Group - No. 008958332 EUIPO - Alicante, Spain
ELECTRA products are registered as Industrial Models at EUIPO - Alicante, Spain
The products are
CE certified.
License by
R709 ICPE
ELECTRA
Bischoffgasse 5/3-4, 1120 Wien - AT
+43 1 810 20 99
Building Communications GmbH
www.electra-automation.at
Designed and Manufactured by ELECTRA Made in EU
Table of contents
Other Electra Intercom System manuals

Electra
Electra SMART+ User manual

Electra
Electra VPM.1FR02 User manual

Electra
Electra BELLCOME Touch Line User manual

Electra
Electra ATM.0S042 User manual

Electra
Electra SMART+ series User manual

Electra
Electra evolution User manual

Electra
Electra Basic TL User manual

Electra
Electra KIT AUDIO DOOR PHONE basic1 family User manual

Electra
Electra APE.2S1.x&x User manual

Electra
Electra APE.1S1.x&x User manual