manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Electra
  6. •
  7. Intercom System
  8. •
  9. Electra VPM.1FR02 User manual

Electra VPM.1FR02 User manual

VIDEO OUTDOOR PANELS
(1 – 5 Families)
for TL door phone systems
User manual
4 wires
1 Fam. Video 2 Fam. Video
3 Fam. Video 5 Fam. Video
EN
0ContentsEN
1Safety instructions
2Description of the video outdoor panels
4Recommended cables. Installation
5Use of the video outdoor panels
1Safety instructions
2Description of the video outdoor panels
3Functions of the video outdoor panels
= 12 … 14 Vd.c.
+U
294 x 144 x 53 mm
1,52 kg
o o
- 30 C … + 60 C
VPM.1FR02
Video outdoor panelVPM.2SR02
260 x 110 x 33 mm
1,3 kg
= 12 … 14 Vd.c.
+U
294 x 144 x 53 mm
o o
- 30 C … + 60 C
VPM.3FR02
Video outdoor panelVPM.5SR02
260 x 110 x 33 mm
1,3 kg
CMOS, 1/3", 573(H) x 597(V), 800 TVL
video 1 Vpp / 75 W; PAL
70º ± 25º orientable video camera
Case: aluminum + 4 mm chemically toughened glass
IR LEDs, 850 nm, IR-CUT for night vision - 10m
TOUCH keys for call and family name,
backlighted during night
Access – RFID card Access – RFID card
Wall mounting height: 160 cm
1,52 kg
EN
EN
Any intervention on the installation must be performed by AUTHORIZED PERSONNEL!
DO NOT power the product at 110 – 230 Va.c.!
DO NOT hit the glass screen with hard objects!
If the glass screen is broken, DO NOT touch the product.
Protect the products against lime and dust during renovation activities.
o
70
175 cm
130 cm
115 cm
160 cm
o
20
o
50
6Maintenance of the video outdoor panels
7Warranty
EN
1
3Functions of the video outdoor panels
4Recommended cables. Installation.
The outdoor panel is mounted on the wall at a height of 1.60 m from the upper edge of the panel (see page 1).
Depending on the maximum distance between the outdoor panel and the last terminal in the installation, the recommended
cables are the following:
2
Option 1) 4 wires x 0.5 mm (type H03VV-F4G 0.5) for maximum 75 lm
2
Option 2) 4 wires x 0.75 mm (type H05VV-F4G 0.75) for maximum 150 lm
Build features:
Solid mechanical construction, built in embedded technology, with chemically toughened glass.
Weatherproof, waterproof and with an operating temperature range between -30º…+ 60º C.
Electronic anti-condensation system for the video camera screen.
Anti-theft sensor that is activated during unauthorized unmounting from the wall.
Day/night sensor for the command of TOUCH keyboard backlighting and the lighting of the IR LEDs and IR-CUT.
TOUCH keyboard with the name of the resident, backlighted during night.
1/3 CMOS, 900TVL color video camera and IR LEDs for b/w image during night.
Blinking red LED, signaling the presence of potential video monitoring from the panel.
In-built RFID reader. Access by secured RFID tag/card.
Allows the connection of a DVR, for extended monitoring and video recording from the panel.
Settings/Programming
Programming and deletion of RFID building access tags/cards.
Programming of new address 2, 3 or 4, for parallel connected panels, in case of buildings with multiple entrances.
(maximum 4 outdoor panels for one building).
Enabling or disabling of video monitoring signaling (Red LED ON/OFF), through the JP1: RED LED/0. (ch. 4.1-step 4)
Enabling or disabling DVR video recording (ON/OFF) through the jumper JP40: 1-2 (OFF) / 2-3(ON) (ch. 4.1)
Extensions
Allows the parallel connection of maximum 4 outdoor panels, through a video selection box (VSB).
Allows the connection of an additional video camera directly to the central supply unit (SCU), or of 4 additional
video cameras, through a video selection box (VSB).
Connections
to the VPM
outdoor panel
+U
C/D
GND
+U
C/D
GND
UTP cat5e (AWG24)
UTP cat6e (AWG23)
25-30mm
6mm
VinVout
6mm
25-30mm
Connections
to the SCU
central supply unit
+U
C/D
GND
Vin
+U
C/D
6mm
25-30mm
GND
Vout
6mm
25-30mm
Connections
to the SCU
central supply unit
Connections
to the VPM
outdoor panel
EN
2
*Important:
Maintain the same colors for the same connections.
Example: +U = Red, C/D = Blue, GND = Black, Vin/Vout = Green.
For electrical safety reasons, we recommend installing an earthing cable between the panel and the SCU, connected to an
earth grounding (ISO - IEC 60950-1:2005)
Option 3) UTP cat5e (AWG24) or UTP cat6e (AWG23), for maximum 250 lm
The wires will be arranged as per the below table:
EN
EN
o
70
4.1 Installation of the smart Video Outdoor Panel (VPM)
STEP 1
Mounting on the wall - Flush
Only for maximum 8 fam. video outdoor panels
Setting of image recording on DVR from the outdoor panel, with JP2: DVR
o
+25
o
+25
o
25
o
25
o
30
o
30
EN
3
5cm ≈20cm ≈20cm
1.5
cm
Mount back the family name module
Signaling of video monitoring: JP1 on RED LED position
No video monitoring signaling: JP1 on 0 position
Mounting on the wall - Surface
Unmount the module and add name labels
EN
STEP 2
STEP 3
STEP 4
STEP 5
JP1
RED
LED 0
o
70
0
JP2
DVR
DVR
JP 2
0
Video camera angle adjustment. (The video camera will be oriented towards the entrance door/gate!).
Torx
Flush
Torx
Electrical connections diagram for the smart Video Outdoor Panel (VPM)
Electrical connections in the panel
Torx
Mounting the outdoor panel on the wall
Surface
Important: For both types of mounting, the Torx screws for fastening the outdoor panels on the
wall will be very well tightened, to prevent the anti-theft alarm sensor from setting off.
+U
C/D
GND
Vout
+U
C/D
GND
Vout
4.2 EN
STEP 1STEP 1.1
EN
4
+U
C/D
GND
Vin
+U
C/D
GND
Vout
+U
C/D
GND
Vout
Electrical connections diagram for 1 and 2-family residences
Vcam
+U
GND
Vin2
110Va.c., 50Hz, 60Hz
230Va.c., 50Hz, 60Hz
SWC 1
SWC 2
SWC
LC 1
LC 2
LCK
AUX 1
AUX 2
LA 1
LA 2
LS 1
LS 2
AUX
,
L N
2x6Aa.c.
Fam. 1
(address 1)
VPM
(address 1)
GNG 2
GNG 1
DBL 1
DBL 2
Doorbell
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vin
+U
C/D
GND
Vin
OUT IN
Fam 1
GONG
4.3 EN
Vcam
+U
GND
Vin2
110Va.c., 50Hz, 60Hz
230Va.c., 50Hz, 60Hz
SWC 1
SWC 2
SWC
LC 1
LC 2
LCK
AUX 1
AUX 2
LA 1
LA 2
LS 1
LS 2
AUX
,
L N
2x6Aa.c.
VPM
(address 1)
+U
C/D
GND
Vout
+U
C/D
GND
Vin
OUT IN
Fam 2
GNG 2
GNG 1
DBL 1
DBL 2
Doorbell GONG
Fam. 1
(address 1)
+U
C/D
GND
Vin
Note2: Any type of TL terminal can be mounted indoors.
For Fam. 1, the terminal has address 1, which is set by the producer.
The additional terminals mounted in parallel will have the address of the main terminal
For Fam. 2, the terminal will be programmed with address 2. See Ch. 6
of the user manual for TL audio-video terminals.
Note1: For residences with 1 family and one entrance (entrance 1),
the outdoor panel has address 1, which is set by the producer.
For multiple entrances: Entrance 2, Entrance 3, Entrance 4, panels
2, 3 and 4 will be programmed according to the procedure in Ch. 4.6.
GNG 2
GNG 1
DBL 1
DBL 2
Doorbell GONG
Fam. 2
(address 2)
SCU
OUT1
+U
PROG
BAT 110/230V
OUT2
SCU
OUT1
+U
PROG
BAT 110/230V
Fam 1
EN
5
Vcam
+U
GND
Vin2
110Va.c., 50Hz, 60Hz
230Va.c., 50Hz, 60Hz
SCU
OUT1
+U
PROG
BAT 110/230V
SWC 1
SWC 2
SWC
LC 1
LC 2
LCK
AUX 1
AUX 2
LA 1
LA 2
LS 1
LS 2
AUX
,
L N
2x6Aa.c.
OUT3
+U
C/D
GND
Vin
OUT2
+U
C/D
GND
Vin
GNG 2
GNG 1
DBL 1
DBL 2
Doorbell
+U
C/D
GND
Vout
GNG 2
GNG 1
DBL 1
DBL 2
Doorbell
GNG 2
GNG 1
DBL 1
DBL 2
Doorbell
+U
C/D
GND
Vin
+U
C/D
GND
Vin
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vout
Fam. 3
(address 3) Fam. 2
(address 2)
Fam. 1
(address 1)
VPM
(address 1)
OUT IN
GONG
GONG
GONG
Fam 2
Fam 1
Fam 3
Note: For residences with 3 families and one entrance (entrance 1),
the outdoor panel has address 1, which is set by the producer.
For multiple entrances: Entrance 2, Entrance 3, Entrance 4, panels 2, 3
and 4 will be programmed according to the procedure in Ch. 4.6.
Note: Any type of TL terminal can be mounted indoors.
For Fam. 1, the terminal has address 1, which is set by the producer.
The additional terminals mounted in parallel will have the address of the
main terminal
For Fam. 2 and Fam. 3, the terminal will be programmed with address 2,
respectively address 3. See Ch. 6 of the user manual for TL audio-video
terminals.
Electrical connections diagram for 3-family residences
EN
6
4.4 EN
Electrical connections diagram for 5-family residences
EN
7
Note: Any type of TL terminal can be mounted indoors..
For Fam. 1, the terminal has address 1, which is set
by the producer.
The additional terminals mounted in parallel will have the
address of the main terminal
For Fam. 2, 3, 4 and 5, the terminal will be programmed with
address 2, respectively addresses 3, 4 and 5. See Ch. 6
of the user manual for TL audio-video terminals.
OUT IN
Note: For residences with 5 families and one entrance (entrance 1),
the outdoor panel has address 1, which is set by the producer.
For multiple entrances: Entrance 2, Entrance 3, Entrance 4,
panels 2, 3 and 4 will be programmed according to the
procedure in Ch. 4.6.
VPM
(address 1)
GONG
GONG
GONG
GONG
Vcam
+U
GND
Vin2
110Va.c., 50Hz, 60Hz
230Va.c., 50Hz, 60Hz
+U
C/D
GND
Vin
SCU
OUT1
+U
PROG
BAT 110/230V
SWC 1
SWC 2
SWC
LC 1
LC 2
LCK
AUX 1
AUX 2
LA 1
LA 2
LS 1
LS 2
AUX
,
L N
2x6Aa.c.
OUT2
+U
C/D
GND
Vout
+U
C/D
GND
Vout
Doorbell
GNG 2
GNG 1
DBL 1
DBL 2
+U
C/D
GND
Vin
Doorbell
Fam. 4 (address 4)
GNG 2
GNG 1
DBL 1
DBL 2
+U
C/D
GND
Vin
Doorbell
GNG 2
GNG 1
DBL 1
DBL 2
+U
C/D
GND
Vin
Doorbell
GNG 2
GNG 1
DBL 1
DBL 2
+U
C/D
GND
Vin
OUT 4
OUT 2
OUT 3
OUT 1
+U
C/D
GND
Vin
+U
C/D
GND
Vout
+U
C/D
GND
Vin
Doorbell
GNG 2
GNG 1
DBL 1
DBL 2
GONG
OUT
IN
VCB
Fam. 5 (address 5)
Fam. 3 (address 3)
Fam. 2 (address 2)
Fam. 1 (address 1)
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
4.5 EN
Electrical connections diagram for multiple parallel panels
(more entrances in a building)
EN
8
4.6 EN
To one or
more families
C/D
GND
Vout
+U
C/D
GND
Vout
+U
VPM1 (address 1)
110Va.c.
230Va.c.
+U
C/D
GND
Vin
VPM2 (address 2)
+U
C/D
GND
Vin
+U
C/D
GND
Vin
+U
C/D
GND
Vin
110Va.c.
230Va.c.
110Va.c.
230Va.c.
110Va.c.
230Va.c.
OUT 1
C/D
GND
Vout
+U
C/D
GND
Vin
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
SCU1 SCU2 SCU3 SCU4
VSB
OUT 1 OUT 1 OUT 1
12 3 4
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
VPM3 (address 3) VPM4 (address 4)
Important: One VPM outdoor panel and one SCU central unit will be mounted at each entrance.
The VPM1 panel keeps address 1, which is set from the factory.
The VPM2 panel with address 2 Long press the PROG. button at SCU 2 Long touch the Fam.1 key at the VPM2 panel.
long beep Short touch the Fam.1 key, twice Two short beeps confirmation.
The VPM3 panel with address 3 Long press the PROG. button at SCU 3 Long touch the Fam.1 key at the VPM3 panel.
long beep Short touch the Fam.1 key, three times Three short beeps confirmation.
The VPM4 panel with address 4 Long press the PROG. button at SCU 4 Long touch the Fam.1 key at the VPM4 panel.
long beep Short touch the Fam.1 key, four times Four short beeps confirmation.
Note: After the beep confirmation of the new address in the panel, go to the SCU of the panel and short press the
PROG. button. The programming of the address is finished.
The programming of the addresses for the panels connected in parallel is done as follows:
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Use of the Video Outdoor Panels
1. STAND-BY: The call keys with the name of the residents are permanently backlighted during night. The Red LED
blinks permanently.
2. CALL: Touch the key corresponding to the name of the family you are looking for. The call is acoustically signaled
with a ding-dong. Each touch of the key reinitiates the call.
4. END OF TALK: - After 1 min. from the call, if the resident does not answer.
- At 10 sec. after the door/gate is opened.
- Immediately, if the resident decides to end the talk without opening the door/gate.
3. TALK: If the resident answers, talk is initiated. The maximum duration of the talk is 2 min.
5. ACCESS: The door/gate will be open during the time set at the SCU (maximum 10 sec.). Access granting is
acoustically signaled through a confirmation beep sequence.
6. RFID TAG/CARD ACCESS: If you program the RFID tags/cards in the outdoor panel, each resident of the building has
access using the secured RFID tag/card from ELECTRA. Approach the tag/card to the RFID area marked on the
outdoor panel. The access is signaled acoustically, through a confirmation beep sequence, and visually – the
symbol blinks white.
EN
9
Manual programming of the RFID TAGs/CARDs in the panel
At the moment of the delivery from the factory, the TL video outdoor panels do not have access tags/cards memorized.
In order to have access in the building after installation, it is mandatory to program the RFID tags/cards in the
outdoor panel.
During programming the installation has to be connected to the grid (110V/230Va.c.) and fully operational.
1. Go to the place where the SCU central unit of the installation is mounted. Long press (3 sec.) the PROG button on
the SCU. The Red LED turns on.
2. Take the RFID tags/cards to the outdoor panels. To program them, approach every tag/card for one second to the
RFID area of the outdoor panel. For each programmed tag/card, the panel issues two short beeps. Repeat this step
for programming all the RFID tags/cards.
3. Go to the place where the SCU central unit of the installation is mounted. Short press the PROG button on the SCU.
The Red LED turns off. The installation returns to normal functioning, successfully ending the programming mode
Orientable video camera
RFID reader.
RFID tag/card access
Microphone
Fastening Torx screw
IR LEDs
(night lighting)
Touch keys for call,
with the name of the residents
Speaker
Fastening Torx screw
1 Fam. 5 Fam.
2 Fam., 3 Fam.
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 1
294 mm
274 mm
115 mm
145 mm
5EN
Deleting the RFID access TAGs/CARDs from the panel
5.2 EN
This procedure applies when you wish to give up access with RFID tags/cards. During the deletion of the RFID
tags/cards, the installation has to be connected to the grid (110V/230Va.c.) and fully operational.
1. Go to the place where the SCU central unit of the installation is mounted. Long press (3 sec.) the PROG button on
the SCU. The Red LED turns on. The installation enters programming mode:
Note: The Red LED can be disabled through jumper JP1 (RED LED) on the board of the keyboard, when the
name labels are added.
5.1 EN
EN
10
2. To delete the RFID access tags/cards from the memory of the panel:
- Long touch the Fam. 1 key until the acoustic confirmation of the panel with a long beep.
- Short touch the Fam. 1 key 7 times. The panel issues two short confirmation beeps.
- Immediately after, long touch (2-3 sec.) the Fam. 1 key. All the codes of the RFID access tags/cards are deleted
permanently. The action is acoustically confirmed by a long beep.
3. Go to the place where the SCU central unit of the installation is mounted. Short press the PROG button on the SCU.
The Red LED turns off. The installation returns to normal functioning mode.
4. Optional: From the outdoor panel, check if the old RFID tags/cards grant access. When each RFID tag/card that has
been deleted from the memory is approached to the panel, a low frequency beep will be issued.
Adding a new RFID access TAG/CARD in the panel
This procedure applies when you wish to add new RFID access tags/cards in the outdoor panel.
1. Collect all the RFID tags/cards from all the people who have access in the building and prepare the new access
tags/cards.
2. First, follow the procedure described in chapter 5.2 for deleting all the tags/cards from the memory of the panel.
3. Follow the procedure described in chapter 5.1. In this case, when you perform point 2 of chapter 5.1, it is mandatory
to approach both the new access tags/cards, and the old tags/cards to the RFID area of the panel,
for reprogramming.
4. After performing point 3 of chapter 5.1, check if access is granted for all the programmed and reprogrammed
RFID access tags/cards.
The Touch Line audio-video terminals must be kept away from water, lime or any liquid substances, blows, fumes, powders,
dust etc.
For cleaning the glass screens, use a clean cloth and a special solution for glass washing.
In case of renovation activities, the entire surface of the panels will be protected with plastic foil.
DO NOT undo the electrical connections of the video door phone installation components.
DO NOT short-circuit the electrical connections of the video door phone installation components.
a. Warranty is granted according to the current legislation in the buyer's country of residence, based on the purchase documents.
b. Warranty is granted for the hidden defects of the components used in production and in case of the system not functioning
according to the present user manual.
WARRANTY IS NOT GRANTED FOR:
c. Inappropriate installation and use.
d. Deterioration, intentional blows.
e. Unauthorized interventions to any of the components of the installation
f. Theft, fire, natural disasters
g. Lack of protection of the installation components in case of renovation activities.
6Maintenance of the video outdoor panels
7Warranty
5.3 EN
EN
EN
Designed and produced by ELECTRA Made in EU 11.2017 USM.VPM.5XR02.ELY04
ELECTRA s.r.l
Bd. Chimiei nr.8,Iași - 700291 - RO
+40 232 214.370 +40 232 232.830
[email protected]
www.electra.ro
ELECTRA
Bischoffgasse 5/3-4, 1120 Wien - AT
+43 1 810 20 99
[email protected]
www.electra-automation.at
Building Communications GmbH
Certificate no. E307311
ISO 9001:2008
ISO 14001:2009
Certificates no. 73 100 4856, 73 104 4856
by TÜV HESSEN
The products are manufactured under
Quality and Environment Management System
The products are
CE certified.
R
The products contain UL-compliant
printed circuit boards.
Certificate by
R709 ICPE
ELECTRA is a trademark of ELECTRA Group - No. 008958332 EUIPO - Alicante, Spain
ELECTRA products are registered as Industrial Models at EUIPO - Alicante, Spain

This manual suits for next models

3

Other Electra Intercom System manuals

Electra ATM.0S042 User manual

Electra

Electra ATM.0S042 User manual

Electra SMART+ User manual

Electra

Electra SMART+ User manual

Electra KIT AUDIO DOOR PHONE basic1 family User manual

Electra

Electra KIT AUDIO DOOR PHONE basic1 family User manual

Electra evolution User manual

Electra

Electra evolution User manual

Electra BELLCOME Touch Line User manual

Electra

Electra BELLCOME Touch Line User manual

Electra APE.1S1.x&x User manual

Electra

Electra APE.1S1.x&x User manual

Electra APE.2S1.x&x User manual

Electra

Electra APE.2S1.x&x User manual

Electra SMART+ series User manual

Electra

Electra SMART+ series User manual

Electra Basic TL User manual

Electra

Electra Basic TL User manual

Electra Touch Line Series User manual

Electra

Electra Touch Line Series User manual

Popular Intercom System manuals by other brands

V-Tec AT27TD7 user manual

V-Tec

V-Tec AT27TD7 user manual

RTS MC-ADAM Hardware guide

RTS

RTS MC-ADAM Hardware guide

Toa RS-410EC e operating instructions

Toa

Toa RS-410EC e operating instructions

Sigtronics SPA-600 Installation and operating instructions

Sigtronics

Sigtronics SPA-600 Installation and operating instructions

Fanvil i20S Quick installation guide

Fanvil

Fanvil i20S Quick installation guide

Panasonic VF540-V quick start guide

Panasonic

Panasonic VF540-V quick start guide

Vimar ELVOX 40135 Installer's guide

Vimar

Vimar ELVOX 40135 Installer's guide

Videx 4000 Series manual

Videx

Videx 4000 Series manual

Aiphone IX SERIES Web Setting Manual

Aiphone

Aiphone IX SERIES Web Setting Manual

Amroad DP3211 installation manual

Amroad

Amroad DP3211 installation manual

Vimar ELVOX Pixel Series Installer's guide

Vimar

Vimar ELVOX Pixel Series Installer's guide

urmet domus VOG 5W Installation handbook

urmet domus

urmet domus VOG 5W Installation handbook

Futura Digital VDT591 user manual

Futura Digital

Futura Digital VDT591 user manual

Extel WECR 61004 Installation and user guide

Extel

Extel WECR 61004 Installation and user guide

3M Audio Greeter A300 installation instructions

3M

3M Audio Greeter A300 installation instructions

chinavasion CVAEE-J108 user manual

chinavasion

chinavasion CVAEE-J108 user manual

urmet domus VOG 5 User handbook

urmet domus

urmet domus VOG 5 User handbook

urmet domus IPerCom 1160/3 User handbook

urmet domus

urmet domus IPerCom 1160/3 User handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.