VERIFY CONTROL BOARD SOFTWARE
1) To verify the software program of the control board the unit will
need to be shut down and restarted. The chiller (if present) does
not need to be shut down and restarted.
2) Shut down the unit by unplugging the power cord from the wall
outlet or switching off the circuit breaker to the unit.
3) Restart the unit by plugging the power cord back into the wall
outlet or by switching on the circuit breaker to the unit.
4) Upon start up, the bottle count display will show the software
designation of BF11 or BF12.
ACCESSING THE PROGRAMMING BUTTON
7RDFFHVVWKHSURJUDPEXWWRQUHPRYHVFUHZSXOOEDFN
cover plate on lower fountain arm (Fig. 5). Reset button is located
above fountain arm.
RESET THE FILTER MONITOR
,QVWUXFWLRQVDSSO\WR¿OWHUHGXQLWVRQO\
'HSUHVVWKHSURJUDPEXWWRQIRUDSSUR[LPDWHO\VHFRQGVXQWLO
the display changes then release. The display will change and
scroll through two messages:
“RST FLTR” – Reset Filter Monitor
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again the display will scroll
through the two messages above for three cycles and then default
back to bottle count and be back in run mode.
3) When the display changes to “RST FLTR”, depress the button
again. The display will change to show “FLTR =”. Depress the
button again and the display will show “FLTR =0”
4) The Green LED should be illuminated indicating that the visual
¿OWHUPRQLWRUKDVEHHQUHVHW
SETTING RANGE OF THE IR SENSOR WHERE APPLICABLE
'HSUHVVWKHSURJUDPEXWWRQIRUDSSUR[LPDWHO\VHFRQGVXQWLO
the display changes then release. The display will change and
scroll through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again the display will scroll
through the two messages above for three cycles and then default
back to bottle count and be back in run mode.
2) When the display changes to “SETTINGS”, depress the button
again. The display will change to show
“RNG SET” - Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
³)/76,=(´6HOHFW¿OWHUFDSDFLW\
“RST BCNT” - Reset bottle count
3) When display shows “RNG SET” push program button once the
display will show current value (can be 1 – 10) e.g. “RNG = 3”.
4) Once display shows current value push the program button to
scroll through value of 1 – 10. Select the desired range setting,
"1" being closest to sensor and "10" being farthest away.
2QFHUDQJHLVVHOHFWHGDOORZDSSUR[LPDWHO\VHFRQGVWRSDVVDQG
then the display will go back to bottle counter and be in run mode.
7HVWERWWOH¿OOHUE\SODFLQJERWWOHRUKDQGLQIURQWRIVHQVRUWR
make sure water is dispensed.
SETTING UNIT TYPE
'HSUHVVWKHSURJUDPEXWWRQIRUDSSUR[LPDWHO\VHFRQGVXQWLOWKH
display changes then release. The display will change and scroll
through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again the display will scroll
through the two messages above for three cycles and then default
back to bottle count and be back in run mode.
2) When the display changes to “SETTINGS”, depress the button
again.
The display will change to show
“RNG SET” - Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
³)/76,=(´6HOHFW¿OWHUFDSDFLW\
“RST BCNT” - Reset bottle count
Continued from below:
3) When display shows “UNIT TYPE” push program button once the
display will show current value. Can be REFRIG or NON-RFRG
4) Push button once to change value. Once value is selected the display
will show the new value. (Can be REFRIG or NON-RFRG)
³5()5,*³VWDQGVIRUUHIULJHUDWHGSURGXFW,QWKLVVHWWLQJWKHÀRZUDWHLV
estimated at 1.0 gallon per minute.
“NON-RFRG“ - stands for nonrefrigerated product. In this setting the
ÀRZUDWHLVHVWLPDWHGDWJDOORQVSHUPLQXWH%RWK³5()5,*³DQG
“NON-RFRG“ simulate 1 bottle equal to 20 oz.
5) $OORZDSSUR[LPDWHO\VHFRQGVWRSDVVDQGWKHGLVSOD\ZLOOUHWXUQWR
bottle counter and be in run mode.
RESETTING BOTTLE COUNT
'HSUHVVWKHSURJUDPEXWWRQIRUDSSUR[LPDWHO\VHFRQGVXQWLOWKH
display changes then release. The display will change and scroll
through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again the display will scroll through
the two messages above for three cycles and then default back to bottle
count and be back in run mode.
2) When the display changes to “SETTINGS”, depress the button again.
The display will change to show:
“RNG SET”- Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
³)/76,=(´6HOHFW¿OWHUFDSDFLW\
“RST BCNT” - Reset bottle count
If the button is not pushed again the display will scroll through the four
messages above for three cycles and return to run mode.
3) When display shows “RST BCNT” push program button once the
GLVSOD\ZLOOVKRZFXUUHQWYDOXHHJ³´
4) Once display shows current value push the program button once more
WRUHVHWEDFNWR7KHGLVSOD\ZLOOVKRZ%7/&7 IRUDSSUR[LPDWHO\
seconds and then return to run mode showing 00000000 bottles.
NOTE: Once the bottle count is reset to zero there is no way to
return to the previous bottle count.
5) Testing the bottle counter:
5()5,*XQLWV3ODFHERWWOHRUKDQGLQIURQWRIVHQVRUIRUDSSUR[LPDWHO\
9 seconds to see bottle counter count 00000001,
7KLVLVEDVHGRQ¿OOLQJDR]ERWWOH
NON-RFRG units: Place bottle or hand in front of sensor for
DSSUR[LPDWHO\VHFRQGVWRVHHERWWOHFRXQWHUFRXQW
7KLVLVEDVHGRQ¿OOLQJDR]ERWWOH
SETTING FILTER CAPACITY
'HSUHVVWKHSURJUDPEXWWRQIRUDSSUR[LPDWHO\VHFRQGVXQWLOWKH
display changes then release. The display will change and scroll through
two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again the display will scroll through
the two messages above for three cycles and then default back to bottle
count and be back in run mode.
2) When the display changes to “SETTINGS”, depress the button again.
The display will change to show:
“RNG SET“- Range set for IR sensor.
“UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)
³)/76,=(´6HOHFW¿OWHUFDSDFLW\
“RST BCNT“ - Reset bottle count
If the button is not pushed again the display will scroll through the four
messages above for three cycles and return to run mode.
3) When display shows “FLT SIZE” push program button once. The display
will show current value. Can be 3000GAL or 6000GAL.
4) Push program button again to display the desired “FLT SIZE”.
$OORZDSSUR[LPDWHO\VHFRQGVWRSDVVDQGWKHGLVSOD\ZLOOUHWXUQWR
bottle counter and be in run mode.