INSTALLATION INSTRUCTIONS
1. Install mounting frame. See rough-in diagram (Figure 4) and mounting frame installation instructions.
2. Install remote chiller. Verify that lter has been installed inside chiller. Slide chiller onto shelf and center it within the shelf
guides. NOTE: Building construction must allow for adequate air ow on both sides, top, and back of chiller. See chiller
instructions for additional information.
3. Make water supply connections. Install a shut-off valve and union connection to building water supply (valve and union
not provided).
4. Make connection between chiller inlet and building supply line (3/8" O.D. copper tube). DO NOT SOLDER TUBES
INSERTED INTO THE UNIONS AS DAMAGE TO THE O-RINGS MAY RESULT. (See Figure 10).
5. Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting frame. Be
sure that panel is engaged with hanger at top of frame before releasing it.
6. Install the fountain. Remove access cover plate on underside of fountains and save the screws. Mount the fountain to
the upper panel and the wall frame with (4) 5/16" x 3/4" (19mm) long bolts and nuts (provided). Tighten securely.
7. Insert waste tube (provided) into drain on fountain. Attach waste tube (1-1/4" O.D.) to 1-1/4" O.D. slip trap (provided by
others).
8. Make connections between remote chiller and fountain. Outlet port is marked on the chiller (3/8" O.D. copper tube).
Install a 3/8" x 1/4" union (provided) on the marked chiller outlet port. Insert the 1/4" poly tubing coming from the fountain
into the union. Turn on water supply, ush line thoroughly, and check for leaks. DO NOT SOLDER TUBES INSERTED
INTO THE UNIONS AS DAMAGE TO THE O-RINGS MAY RESULT. (See Figure 10).
9. These products are designed to operate on 20-105 PSI (0.14-0.72 MPa) supply line pressure. If inlet pressure is above
105 PSI (0.72 MPa), a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting
these products to supply line pressures lower than 20 PSI (0.14 MPa) or higher than 105 PSI (0.72 MPa) is not covered
by warranty.
10. Make electrical connections to the chiller. See chiller instructions.
11. Check stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this,
adjust the screw on regulator item 10 by using a small screwdriver through the small hole in the push button item 3
(See Figure 3). Clockwise adjustment will raise stream height and counter-clockwise will lower stream height. For best
adjustment stream should hit basin approximately 6-1/2" from the bubbler.
12. Mount lower panel. Slide upper ange of lower panel up and behind lower edge of already installed upper panel. Tighten
previously loosened screws securely. Install (2) #10-24 x 5/8" (16mm) screws at frame bottom lip.
13. Replace bottom access panel to fountain basin using screws provided. Tighten securely.
TROUBLE SHOOTING AND MAINTENANCE
1. Orice Assy: Mineral deposits on orice can cause water ow to spurt or not regulate. Mineral deposits may be removed
from orice with a small round le not over 1/8" diameter or a small diameter wire.
CAUTION: Do not le or cut orice materials.
2. Stream Regulator: If orice is free of material deposits, regulate ow according to instruction 11 stated above.
3. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water
seal. To remove tubing from the tting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Fig. 1)
To insert tubing, push tube straight into the tting until it reaches a positive stop, approximately 3/4".