manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elkay
  6. •
  7. Timer
  8. •
  9. Elkay BDH 550B-1 Manual

Elkay BDH 550B-1 Manual

Other Elkay Timer manuals

Elkay 570A-1 Manual

Elkay

Elkay 570A-1 Manual

Elkay 374B-1 Manual

Elkay

Elkay 374B-1 Manual

Elkay Energy sense User manual

Elkay

Elkay Energy sense User manual

Elkay energysense 380A-1 Manual

Elkay

Elkay energysense 380A-1 Manual

Elkay 374C-1 Manual

Elkay

Elkay 374C-1 Manual

Elkay 350A-1 Manual

Elkay

Elkay 350A-1 Manual

Elkay BDH 3875A-1 Manual

Elkay

Elkay BDH 3875A-1 Manual

Popular Timer manuals by other brands

SATO TM-29 instruction manual

SATO

SATO TM-29 instruction manual

Full Gauge Controls ICEMATIC quick start guide

Full Gauge Controls

Full Gauge Controls ICEMATIC quick start guide

CEI Ultrak T-3 instructions

CEI

CEI Ultrak T-3 instructions

Raindrip R675CT Installation & programming

Raindrip

Raindrip R675CT Installation & programming

Intermatic P1131 owner's manual

Intermatic

Intermatic P1131 owner's manual

Profile 010200280 instruction manual

Profile

Profile 010200280 instruction manual

Gizmo T4 instructions

Gizmo

Gizmo T4 instructions

Tekmar Timer 031 Data brochure

Tekmar

Tekmar Timer 031 Data brochure

Daikin DST301B61 Operation manual

Daikin

Daikin DST301B61 Operation manual

sisel ENDA ETM2432 manual

sisel

sisel ENDA ETM2432 manual

B&Q TE103 Installation and use instructions

B&Q

B&Q TE103 Installation and use instructions

Hozelock AC Plus 2700 instructions

Hozelock

Hozelock AC Plus 2700 instructions

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

Emos EMT400F quick start guide

Emos

Emos EMT400F quick start guide

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Citizen ME2 series instruction manual

Citizen

Citizen ME2 series instruction manual

Primex OneVue Sync B100 install guide

Primex

Primex OneVue Sync B100 install guide

Rain Bird Optima PRT-4 owner's manual

Rain Bird

Rain Bird Optima PRT-4 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The Standard Outdoor Pushbutton
Timer (3 wire) is part of the Elkay
family of switches, timers and
detectors which save energy and
increase convenience in and around
your home, garden or premises.
Rating at 240V ac 50Hz
• Time Delay: 2 min - 1 hour
• Lighting load types only 10A - Including
lighting loads that are LED, Compact
Fluorescent, Incandescent and Resistive
• This switch can also switch contactors
provided a capacitor is fi tted across
the coil
• IP66
Fitting and Operating Instructions
This product can ONLY be used with the
back box supplied and can be used in
outdoor and bathroom applications.
Failure to use the back box provided will
invalidate the warranty. It is essential that
that the correct IP66 rated connections
are made to keep the IP66 rating of
the back box maintained.
1. Take the surface mount box and remove
knockouts as required. Ideally remove
with a hole saw for cleanest eff ect and
remove any burrs. Drill a small 3mm
drain hole at the back of the box in the
position marked ‘DRAIN‘. Drill outwards
from the inside of the box.
2. Mount the surface mount box on a secure
surface using the mounting pack supplied.
Place screw cover seal over the rear
mounting screws after screwing the box
to the wall.
3. It is essential to maintain the IP rating with
all connections to the box. Please use a
suitable M20 cable gland and use
appropriate sealing washers. For steel wired
armoured connections to the box use a nylon
20mm seal to maintain IP rating. Seals have
been provided for your convenience.
4. Prior to fi tting ensure mains power is
switched OFF and live in, live out and neutral
wires are identifi ed. Where applicable
remove metal back box lugs that are
not being used.
5. Securely fi t live in, live out and neutral
wires into terminals marked Lin, Lout & N.
–
STANDARD
OUTDOOR
PUSHBUTTON
TIMER
550B-1
3 wire
Instruction Guide
BROOK DESIGN HARDWARE LTD
BDH
BDH
BROOK DESIGN
HARDWARE LTD
BDHBROOK DESIGN
HARDWARE LTD
BDH
BROOK DESIGN
HARDWARE LTD
BDH
Brook House,
Dunmurry Industrial Estate,
Dunmurry,
Belfast BT17 9HU
T +44 (0)28 9061 6505
F +44 (0)28 9061 6518
E info@elkay.co.uk elkay.co.uk
BROOK DESIGN HARDWARE LTD
BDH
B
DH
BROOK DESIGN
HARDWARE LTD
BDHBROOK DESIGN
HARDWARE LTD
BDH
BROOK DESIGN
HARDWARE LTD
BDH
Diagram 1 – Time settings
Please note: The black bar denotes the position of the dip switch.
10-15 sec 2 mins 3 mins 4 mins 5 mins 7 mins 10 mins 15 mins
TEST MODE
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
20 mins 25 mins 30 mins 35 mins 40 mins 45 mins 50 mins 60 mins
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
LIVE IN
LIVE OUT
NEUTRAL
SL L SL LN
LIVE IN
LIVE OUT
NEUTRAL
SL L
LIVE IN
LIVE OUT
NEUTRAL
SL LN
NSLL
5 - 7m
4 - 6m
5 - 7m
3 - 4m
SL L
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
SL L SL LN N
LIVE IN
LIVE OUT
NEUTRAL
SL L SL LN
LIVE IN
LIVE OUT
NEUTRAL
SL L
LIVE IN
LIVE OUT
NEUTRAL
SL LN
NSLL
5 - 7m
4 - 6m
5 - 7m
3 - 4m
SL L
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
SL L
SL L
N
N
LIVE IN
LIVE OUT
NEUTRAL
SL L SL LN
LIVE IN
LIVE OUT
NEUTRAL
SL L
LIVE IN
LIVE OUT
NEUTRAL
SL LN
NSLL
5 - 7m
4 - 6m
5 - 7m
3 - 4m
SL L
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
SL L
SL L
N
N
Diagram 2 – Wiring
Multiple switchingSingle switching
Important Notice
All wiring should be carried out by a competent person
or a qualifi ed electrician and should be fi tted to current
IEE wiring regulations BS 7671. The circuit should be
isolated before carrying out any work. Failure to adhere
to the instructions will invalidate the warranty.
Technical Helpline
For further help, or information on this and the other products in the Elkay range
go to www.elkay.co.uk or call +44 (0)28 9061 6505. These instructions are
available in other languages. Please refer to our website www.elkay.co.uk
Instrukcje są również dostępne w innych językach. Prosimy o zapoznanie się z
naszą stroną internetową www.elkay.co.uk lub www.elkaypolska.pl
Elkay (Europe), 51C Milicka, Trzebnica, 55-100, Poland
6. Turn mains power ON. Put the product
in 10-15 second test mode.
7. Press the Pushbutton timer button
to switch the load ON. The Pushbutton
timer will turn the Load OFF
automatically once the required time
delay selected has elapsed.
8. The Timer can be also act as an on/off
switch. Press to turn switch ON and to
turn OFF simply press and hold the timer
button for 3 seconds and the load will
switch OFF immediately.
9. Set the required time delay with reference
to Timing Diagram.
10.Once the installation is fully tested and
working as required ensure the timer is
secured to the back box.
11. A capacitor will be required when switching
low power or low energy lighting.
For example: LED, 2-D fi ttings, energy
saving lamps, etc. One capacitor per
circuit must be fi tted at the light fi tting.
Elkay Capacitor Product Code PFCC-1.