WIRELESS
SHUTTER CONTROL
(CLASSIC VERSION)
EN
Combination of iNELS wall-mounted wireless controller and shutter switching device.
Package
On-wall button controller PLASTIC - 2 buttons
RFWB-20/G
Switch unit for shutters
RFJA-32B-SL
Range up
200 m
The individual elements in the iNELS set are paired and their functions are preset.
iNELS Wireless shutters control enables it´s remote control.
The settings of the wall controllers can be changed - see detailed manuals of iNELS elements.
UP/STOP
DOWN/STOP
EAN 8595788183147 (On-wall button controller PLASTIC - 2 buttons + Switch unit for shutters)
56
12
3
4
RFWB-20/G
On-wall button controller
2 buttons RFWB-20/G
Characteristics
• The wireless controller is used to control switches and dimmers (lights, gate, garage door,
blinds, etc.).
• RFWB-20/G: two buttons enable control one or two units independently (depending on the
type of switching element).
• The flat design with level base makes it ideal for fast installation on any surface (fixation with
adhesive or screws in the installation box).
Safe handling
Replacement of a battery RFWB-20
Using a screwdriver,
carefully pry o
the device from the
frame.
Slide the CR2032
battery into the
battery holder.
Observe the
polarity.
Snap on the cover.
The LED opening
must be located
in the upper part
(for the RFWB-
40, observe the
positioning of the
left and right cover
Place the frame
on the rear part.
Snap the device
with the cover
into the prepared
frame.
When handling a device unboxed it is important to avoid contact with liquids. Never place the device
on the conductive pads or objects, avoid unnecessary contact with the components of the device.
Detailed manual
Gently pull to
remove the cover.
RFWB-20/GTechnical parametres
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.
Supply voltage:
Transmission indication:
Number of buttons:
Transmitter frequency:
Signal transmission method:
Range in free space:
Other data
Operating temperature:
Operating position:
Mounting:
Protection:
Contamination degree:
Dimensions:
LOGUS90 frame - plastic:
LOGUS90 frame
- metal, glass, wood, granite:
Weight:
Related standards:
3 V battery CR 2032
red LED
2
868.5 MHz
unidirectionally addressed message
up to 200 m
-10 ... +50 °C (14 ... 122 °F)
any
glue, screws
IP20
2
85 x 85 x 16 mm (3.3“ x 3.3“ x 0.6“)
94 x 94 x 16 mm (3.7“ x 3.7“ x 0.6“)
38g * (1.3 oz)
EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No
426/2000 Coll.
(Directive 1999/EC)
* Comes with plastic frame.
RFJA-32B-SL
Switch unit for shutters
RFJA-32B-SL
Characteristics
• The switching unit for blinds has 2 output channels used to control garage doors,
gates, blinds, awnings, etc…
• It can be combined with system components iNELS RF Control2with RFIO2protocol.
• The BOX design lets you mount it right in an installation box, a ceiling or motor drive cover.
• Short presses of the controller enable tilting of lamellas, and a long press enables you to draw the blinds up
or down to the end position.
• Each of the units may be controlled by up to 25 channels (1 channel represents one assigned controller).
• The programming button on the unit is also used for manual control of the output.
• For components it is possible to set the repeater function via the RFAF / USB service device.
• Range up to 200 m (in open space), if the signal is insucient between the controller and unit, use the
signal repeater RFRP-20 or protocol component RFIO2that support this feature.
• Communication frequency with bidirectional protocol iNELS RF Control2(RFIO2).
Detailed manual
Installationoptions
mounting into a non-conducting drive housing flush mounting ceiling mounted
RFJA-32B-SLTechnical parameters
230 V AC / 50 - 60 Hz
7 VA / cos φ= 0.1
0.7 W
+10 -15 %
2x switching (AgSnO2)
8 A / AC1
2000 VA / AC1
10 A / <3 s
250 V AC1
868.5 MHz
PROG (STOP, , STOP, )
-15 ... + 50 °C (5 ... 122 °F)
any
free at lead-in wires
IP30
III.
43 x 44 x 22 mm
45 g
EN 60730, EN 63044, EN 300 220, EN 301 489
Supply voltage:
Apparent input:
Dissipated power:
Supply voltage tolerance:
Output:
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Control:
RF, by command from transmitter:
Manual control:
Other data:
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltage category:
Dimensions:
Weight:
Related standards:
L
NSS
L
N
PE
M
1
2
35
46
Indication, manual control
•LED STATUS - indication of the device status.
• Manual control is performed by pressing the PROG button.
• Programming is performed by pressing the PROG button for more than 1s.
• Terminal block for connection of buttons. IN1 - direction button up IN2- button down.
In the programming and operating mode, the LED on the component lights up at the
same time each time the button is pressed - this indicates the incoming command
Connection
1. LED / button PROG
2. Addresses for individual relays (channels)
3. Terminal block - connection for external button
4. Terminal block - connecting the neutral conductor
5. Terminal block - load connection
6. Terminal block for connecting the phase conductor
60 - 90 % 80 - 95 % 20 - 60 % 0 - 10 % 80- 90 %
x
RFRP-20
Radiofrequency signal penetration through various construction materials
brick walls wooden structures
with plaster boards reinforced concrete metal partitions common glass
Range up to 200 m in open space, if the signal is insucient between the controller and unit, use the signal
repeater RFRP-20 or protocol component RFIO2that supports this feature.
Instruction manual is designated for mounting and also for the usafe of the device. It is always a part of its pac-
king. Installation and connection can be carried out only by a person with adequate professional qualification
with understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller.
It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before
starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting
and servicing observe safety regulations, norms, directives and professional, and export regulations for working
with electrical devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity
of RF signal, observe correct location of RF components in a building where the installation is taking place. RF
Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors
and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal
door – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – radio-
frequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get flat etc. and
thus disable remote control.
Warning
Designed & Manufactured by:
ELKO EP, s.r.o. Palackého 493, 769 01 Holešov, Všetuly,
Czech republic, www.elkoep.com, Hotline: +420 800 100 671

Other manuals for RFWB-20/G

6

Other Elko Home Automation manuals

Elko Inels Air AirIM-100L User manual

Elko

Elko Inels Air AirIM-100L User manual

Elko iNELS Bridge User manual

Elko

Elko iNELS Bridge User manual

Elko Smart User manual

Elko

Elko Smart User manual

Elko SmartDim EKO0727 Series User manual

Elko

Elko SmartDim EKO0727 Series User manual

Elko Smart EKO09692 User manual

Elko

Elko Smart EKO09692 User manual

Elko iNels RFSA-61M User manual

Elko

Elko iNels RFSA-61M User manual

Elko RF KEY User manual

Elko

Elko RF KEY User manual

Elko EKO07699 User manual

Elko

Elko EKO07699 User manual

Popular Home Automation manuals by other brands

WOOX R7047 quick start guide

WOOX

WOOX R7047 quick start guide

Freedompro Easykon for KNX Quick manual

Freedompro

Freedompro Easykon for KNX Quick manual

Samsung HD2018GH user manual

Samsung

Samsung HD2018GH user manual

Cytech VI-CON-SYS-01 installation guide

Cytech

Cytech VI-CON-SYS-01 installation guide

NuTone NWO15Z quick start guide

NuTone

NuTone NWO15Z quick start guide

Frontpoint TOUCHSCREEN Get started

Frontpoint

Frontpoint TOUCHSCREEN Get started

DELTA DORE TYDOM 3.0 Configuration guide

DELTA DORE

DELTA DORE TYDOM 3.0 Configuration guide

IntesisHome PA-AW-WIFI-1 installation guide

IntesisHome

IntesisHome PA-AW-WIFI-1 installation guide

Miboxer Mi-Light SWE01 instruction manual

Miboxer

Miboxer Mi-Light SWE01 instruction manual

Hitachi CH-UNIT Installation and operation manual

Hitachi

Hitachi CH-UNIT Installation and operation manual

urmet domus Bitron Home 902010/21 Quick start manual

urmet domus

urmet domus Bitron Home 902010/21 Quick start manual

Velux KUX 110 manual

Velux

Velux KUX 110 manual

3Sense Pro-E 4.0 user manual

3Sense

3Sense Pro-E 4.0 user manual

Silux Control Tolleno Operation manual

Silux Control

Silux Control Tolleno Operation manual

ZooZ MULTIRELAY ZEN16 instructions

ZooZ

ZooZ MULTIRELAY ZEN16 instructions

Ednet 84291 Quick installation guide

Ednet

Ednet 84291 Quick installation guide

EVE button 20EAU9901 Get started

EVE

EVE button 20EAU9901 Get started

TP-Link Kasa Smart KP401 user guide

TP-Link

TP-Link Kasa Smart KP401 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.