WARNING
•Please read these instructions before installing or using this appliance for the first
time. The warranty of the combined storage heater will not cover any damage
caused by non observance of any of these instructions.
•This Guide must be kept and given to any new owner.
•The installation of the heater should be carried out by trained personnel.
•Should the heater be moved and reinstalled it is essential that the work is carried
out by trained personnel.
•If during any reinstallation the thermal insulation shows any sign of damage, it is
necessary for the faulty part to be removed and replaced by an identical part.
•The use of storage heaters is forbidden in any area where there is a presence of
gases, explosives or inflammable objects.
•Do not use this heater to dry clothes.
•Do not cover this heater at any time.
•Do not place objects in contact with the heater.
•The air outlet grill at the top of the heater cabinet and the air inlet at the bottom of
the heater are provided to ensure the most efficient operation of the appliance.
They also protect the heater from overheating, therefore, it is essential that at no
time are they covered.
•This heater should be switched off at the isolating switch before any repair work is
carried out. This action should also be taken during the times of the year when
heat is not required.
•The installation of the heaters must be carried out in such a way that each pole can
be disconnected from the supply having a contact separation of at least 3 mm.
•The storage heater should not be installed just below an electrical socket.
•The appliance must be installed in such a way that it is impossible for anyone
using a bath or shower, to touch the controls.
•The nominal charging time of this storage heater must be controlled by means of a
programmer.
•The installation must be carried out in accordance with the current electrical
regulations.
•This appliance must be earthed.
•After installation a survey of the first charging cycle should be carried out to ensure
that the main input thermostat switches off. Ventilate the room during this first
cycle.
•Before carrying out any work inside the appliance, the heater must be
disconnected from the electricity supply.
•Never open a charged heater.
•The presence in the air of particles of smoke, dust and other pollutants could, in
time, discolour the walls and surfaces around the heater.
•To maintain stability, it is essential that the heater is placed on a level surface and
care should be taken to avoid irregular surfaces, such as may result from carpets
or tiled surrounds partially protruding under the heater.
- 1 -
By leaving in this position, the heater will automatically maintain the selected temperature.
It is recommended to switch off the convector at the beginning of the overnight charge.
Models CSH12A, CSH18A and CSH24A:
The direct acting convector element should be switched off prior
to the storage heaters night time charge period engaging. This
is to avoid the possibility of the automatic charge regulator
reducing the total charge taken, due to it reading a high room
temperature.
MAINTENANCE OF YOUR COMBINED STORE HEATER
This storage heater does not require any special care. During the first few charges you may be
aware of an unusual odour. This is normal and if it happens, please ventilate the room until the
odour disappears.
If dust accumulates on the heater surface it can be removed using a wet cloth when the heater is
cold. Do not use solvents or a abrasive products.
WIRING DIAGRAMS
R1, R2, R3, R4…Heating elements CE…… Convector element with built in thermal cut out
RAC………...Accelerating resístance C…….. Switch
Tc…………..Charge control thermostat PE…… Earth
Ts…………..Safety cut out L………Phase
Ta…………..Ambient thermostat N…….. Neutral
- 6 -