Indoor Sensor WGTH-UP 1
Indoor Sensor WGTH-UP • Version: 01.04.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250
EN
Indoor Sensor WGTH-UP
For WS1 Color/Style, (KNX) WS1000 Color/Style
Technical specifications and installation instructions
Item numbers 20550, 20551
1. Description
The WGTH-UP Indoor Sensor transfers temperature and humidity to the control sys-
tem via radio. Several separate WGTH-UP can be taught to one control system. The
teaching is described in the chapter “Learn wireless connections” (manual of the
control system).
The WGTH-UP Indoor Sensor consists of the housing, the sensor PCB/base plate
and a frame. As an alternative to the supplied frame, a frame of the switch series
used in the building may be used. You will additionally require a junction box (Ø 60
mm, 42 mm deep, not included in scope of delivery).
For power supply (11…28 V DC), e. g. 12 V DC can be tapped from the connection
board of the control unit (multifunctional input).
2. Installation of the indoor sensor
2.1. Installation location
The interior sensor is to be installed flush to the wall surface in a junction box (Ø 60
mm, 42 mm deep). The ideal installation hight is approx. 1.40 m above the ground.
When selecting an installation location, please ensure that the measurement results
are affected as little as possible by external influences. Possible sources of interfe-
rence include:
• Direct sunlight
• Drafts from windows and doors
• Draft from ducts which lead from other rooms to the junction box in which the
sensor is mounted.
• Waste heat from the control unit (when mounted above the display)
• Warming or cooling of the building structure on which the sensor is mounted,
e.g. due to sunlight, heating or cold water pipes
• Connection lines which lead from warmer or colder areas to the sensor
Temperature variations from such sources of interference must be corrected in the
control unit menu in order to ensure the specified accuracy of the sensor (see ma-
nual chapter on Wireless connections > Status).
The indoor sensor must only be installed and used in dry,
interior spaces. Avoid condensation.
2.2. Layout
2.3. Rear view
2.4. Installation
First install the junction box. Seal the inlet tubes in order to prevent drafts.
Connect the power supply +/- to the connector terminals provided for this purpose
on the sensor board. Then screw the board/base plate onto the socket. Ensure that
the front side with the writing „TOP“ is directing out of the wall and that the arrows
point towards the top.
Position the frame of the switching programme. Insert the housing of the sensor
firmly onto the base plate using the catches, so that the housing and frame are fixed
together.
3. Notes on mounting and commissioning
Never expose the device to water (e.g. rain) or dust. This can damage the electro-
nics. You must not exceed a relative humidity of 95%. Avoid condensation.
4. Establish radio connection with WGTH-UP
1. Bring the control unit into learning readiness mode (note chapter Learn wireless
connection in the manual).
2. Press the programming button at the WGTH-UP sensor
3. Pay attention to the report of the control unit (“Device successfully learnt”).
5. Installation notes
Installation, testing, operational start-up and troubleshooting should
only be performed by an electrician.
CAUTION!
Live voltage!
There are unprotected live components inside the device.
• National legal regulations are to be followed.
• Ensure that all lines to be assembled are free of voltage and take
precautions against accidental switching on.
• Do not use the device if it is damaged.
• Take the device or system out of service and secure it against
unintentional use, if it can be assumed, that risk-free operation is
no longer guaranteed.
The device is only to be used for its intended purpose. Any improper modification
or failure to follow the operating instructions voids any and all warranty and gua-
rantee claims.
After unpacking the device, check it immediately for possible mechanical damage.
If it has been damaged in transport, inform the supplier immediately.
The device may only be used as a fixed-site installation; that means only when as-
sembled and after conclusion of all installation and operational start-up tasks and
only in the surroundings designated for it.
Elsner Elektronik is not liable for any changes in norms and standards which may
occur after publication of these operating instructions.
6. Technical specifications WGTH-UP
Fig. 1
1 Openings for air circulation
2 Opening programming LED
4 Opening programming but-
ton for configurating the de-
vice
5 Openings for air circulation
(BOTTOM)
3
1
2
4
Fig. 2
1 Connection for power sup-
ply 11…28 V DC (+/-)
1
Housing Plastic (partially painted)
Colours • White, glossy (similar to RAL 9016 Traffic
White)
• Matt aluminium
Installation Flush-mounted (installed in wall within junc-
tion box
Ø 60 mm, 42 mm deep)
Protection rating IP 20
Dimensions Housing approx. 55 × 55 (W × H, mm)
Installation depth approx. 15 mm
Backplate approx. 71 × 71 (W × H, mm)
Total weight approx. 50 g
Ambient temperature Operating -20…+70°C, Storage -55…+90°C
Ambient air humidity max. 95% RH, avoid condensation
Operating voltage 11…28 V DC
Current max. 35 mA
Data output Wireless
Wireless frequency 868.2 MHz
Protocol Proprietary protocol (Elsner RF)
Temperature measure-
ment range
-20…+70°C
Resolution (tempera-
ture)
0.1°C
Accuracy (temperature) ±0,6°C at -20...-10°C
±0,5°C at -10...+65°C
±0,6°C at +65...+70°C
Humidity measurement
range
0…95% RH
The programming button is situated be-
hind the right lower opening of the hou-
sing.
Indoor Sensor WGTH-UP 2
Indoor Sensor WGTH-UP • Version: 01.04.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250
The product conforms with the provisions of EU directives.
Resolution (humidity) 0,1%
Accuracy (humidity) ±7,5% RH at 0...10% RH
±4,5% RH at 10...90% RH
±7,5% RH at 90…95% RH
Drift (humidity) ±0.5% RH per year in normal atmosphere

This manual suits for next models

2

Other elsner elektronik Accessories manuals

elsner elektronik KNX R Guide

elsner elektronik

elsner elektronik KNX R Guide

elsner elektronik KNX AQS/TH-B-UP User manual

elsner elektronik

elsner elektronik KNX AQS/TH-B-UP User manual

elsner elektronik AQS/TH PF User manual

elsner elektronik

elsner elektronik AQS/TH PF User manual

elsner elektronik KNX W Series Guide

elsner elektronik

elsner elektronik KNX W Series Guide

elsner elektronik WG AQS/TH gl User manual

elsner elektronik

elsner elektronik WG AQS/TH gl User manual

elsner elektronik P04i-W User manual

elsner elektronik

elsner elektronik P04i-W User manual

elsner elektronik KNX W sl User manual

elsner elektronik

elsner elektronik KNX W sl User manual

elsner elektronik KNX R Guide

elsner elektronik

elsner elektronik KNX R Guide

elsner elektronik KNX VOC/TH-UP Touch User manual

elsner elektronik

elsner elektronik KNX VOC/TH-UP Touch User manual

elsner elektronik WGTH-UP User manual

elsner elektronik

elsner elektronik WGTH-UP User manual

elsner elektronik KNX VOC/TH-UP Touch CH User manual

elsner elektronik

elsner elektronik KNX VOC/TH-UP Touch CH User manual

elsner elektronik TH-UP basic User manual

elsner elektronik

elsner elektronik TH-UP basic User manual

elsner elektronik KNX TH-UP Touch User manual

elsner elektronik

elsner elektronik KNX TH-UP Touch User manual

elsner elektronik SO250-UI User manual

elsner elektronik

elsner elektronik SO250-UI User manual

elsner elektronik Intra-Sewi KNX T Guide

elsner elektronik

elsner elektronik Intra-Sewi KNX T Guide

elsner elektronik R 24 V User manual

elsner elektronik

elsner elektronik R 24 V User manual

elsner elektronik KNX T-B-UP User manual

elsner elektronik

elsner elektronik KNX T-B-UP User manual

elsner elektronik KNX L User manual

elsner elektronik

elsner elektronik KNX L User manual

elsner elektronik 30170 User manual

elsner elektronik

elsner elektronik 30170 User manual

elsner elektronik WG AQS/TH-UP User manual

elsner elektronik

elsner elektronik WG AQS/TH-UP User manual

elsner elektronik KNX AQS TH-B-UP Guide

elsner elektronik

elsner elektronik KNX AQS TH-B-UP Guide

elsner elektronik 20550 User manual

elsner elektronik

elsner elektronik 20550 User manual

elsner elektronik KNX AQS/TH-B-UP User manual

elsner elektronik

elsner elektronik KNX AQS/TH-B-UP User manual

elsner elektronik KNX L Guide

elsner elektronik

elsner elektronik KNX L Guide

Popular Accessories manuals by other brands

RC Logger 89141RC operating instructions

RC Logger

RC Logger 89141RC operating instructions

Imetec R1502 Instructions for use

Imetec

Imetec R1502 Instructions for use

hailie NF0101 product manual

hailie

hailie NF0101 product manual

WIFO WI-5000-T Manual and safety instructions

WIFO

WIFO WI-5000-T Manual and safety instructions

echoflex Elaho Dual Tech Ceiling-mount Vacancy Sensor installation guide

echoflex

echoflex Elaho Dual Tech Ceiling-mount Vacancy Sensor installation guide

Shop fox SHOP FOX D2254-6 instruction sheet

Shop fox

Shop fox SHOP FOX D2254-6 instruction sheet

Mercury 350.115UK user manual

Mercury

Mercury 350.115UK user manual

HP Kayak XA-s Series 02 install guide

HP

HP Kayak XA-s Series 02 install guide

Evenflo Pivot Xpand Stroller Market Basket instructions

Evenflo

Evenflo Pivot Xpand Stroller Market Basket instructions

Lightolier Lytespan 8675BD12 specification

Lightolier

Lightolier Lytespan 8675BD12 specification

SBS TTBB160002UFLCDK user manual

SBS

SBS TTBB160002UFLCDK user manual

Airnatural Saho user manual

Airnatural

Airnatural Saho user manual

LF Style Selections SS-7904 manual

LF

LF Style Selections SS-7904 manual

PCB Piezotronics IMI Sensors 602D01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI Sensors 602D01 Installation and operating manual

Beurer HK 54 Instructions for use

Beurer

Beurer HK 54 Instructions for use

Backyard Discovery 1706811 owner's manual

Backyard Discovery

Backyard Discovery 1706811 owner's manual

Sony COM-2BLACK - Mylo™ Internet Device license agreement

Sony

Sony COM-2BLACK - Mylo™ Internet Device license agreement

Anritsu MA24104A user guide

Anritsu

Anritsu MA24104A user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.