PR6 / PR7
ELSTER Messtechnik GmbH
Otto-Hahn-Strasse 25
68623 Lampertheim, Germany
T +49 (0) 62 06 933 0
F +49 (0) 62 06 933 100
www.elstermesstechnik.com
Falcon_D_14.02e / 11.10
Changes without notice and
falcities excepted
Copyright ELSTER Messtechnik GmbH
Pulse module Ordering number
CH1P CH2P PR6 PR7
1 litres/pulse*; 10 litres/pulse* 2925M1265 2925M1224
1 litres/pulse*; 100 litres/pulse* 2925M1261 2925M1263
1 litres/pulse*; 1000 litres/pulse* 2925M1262 2925M1264
1 litres/pulse; 1 litres/pulse 2925M1221** —
10 litres/pulse*; 10 litres/pulse* — 2925M1222
25 litres/pulse*; 25 litres/pulse* — 2925M1282**
........................................................................................................................................................................
Connecting cable m 2 5
........................................................................................................................................................................
Battery lifetime 10 years
Operating temperature -15 °C up to +70 °C
Protection class IP68
........................................................................................................................................................................
Output load max. 30 Vdc
max. 30 mA
Frequency max. 75 Hz
Pulse width CH 1P min. 5 ms (typical 8-12 ms)
Pulse width CH 2P min. 50 ms (**CH1P also)
Pulse/pause 1:1 (**CH1P also)
* for meters up to DN 125/Qn 100, from DN 150/Qn 150 upwards pulse rate x 10.
Pin assignment
Pulse module
Pin assignment
CH1P Volume pulses (independent of flow direction),
active „low“
CH1D Direction flag, „high“ = forward flow
CH2P adjusted volume pulse =
forward flow minus backflow,
active „low“.
During a backward flow no pulses are send
to the output. After renewed forward first the
pulse numbers which are stored in the
memory will be deleted. This pulse numbers
are generated from the previous backward
flow. After deleting the memory forward
pulses will be send to the output only.
CH2C Backflow compensations flag.
This flag is „low“, if currently a backflow
compensation is running
TAMP Alarm flag,
signalizes the removal of the pulse module
from the register or low charge of battery,
active „high“
GND Ground
Radio module Ordering number
TPR6 TPR7
internal antenna 2925M1301 2925M1305
external antenna (2 m fixed cable) 2925M1302 2925M1306
.....................................................................................................................................................................
Protocol Wavenis
Frequency technology FHSS (15 radio channels)
(Frequency Hopping Spread Spectrum)
Frequency 868 MHz, ISM band
Type of transmission Bi-directional
Transmitting power mW 25
Range m up to 600 (depending on env. circumstances)
.....................................................................................................................................................................
Connection velocity up to 9.6 kbits/s
Power of emission 8 dBi
Standard CE (EN300-683)
Certification ART (EN300-220-1)
Conformity RTTE 99/5/EC
Operating temperature -15 °C up to +70 °C
Protection class IP68
Battery lifetime up to 15 years
.....................................................................................................................................................................
Protocol content
Minimum Initial meter reading
Pulse value
Data memory 24 values
programmable
– monthly, weekly, daily values
– free interval (1 min - 31 h.)
Alarm signal Battery,
cable break, burst pipe,
backflow,
manipulation
Time management Day/night switch off
weekend switch off
Programming via ECM software
M-Bus module Ordering number
Standard PR6M PR7M
EN1434 2925M1268 2925M1269
........................................................................................................................................................................
Connecting cable m 2 5
2 wires reverse polarity protection
........................................................................................................................................................................
Power supply Remote power supply of the M-Bus
with automatic changeover to battery
if the bus fails
........................................................................................................................................................................
M-Bus operation max. 1.5 mA (1 standard load),
standby current M-Bus max. 1.5 mA, typ. 1.4 mA
........................................................................................................................................................................
Space (0-Bit) current standby current + typ. 13 mA
M-Bus Interface TI TSS721 with 2 x 215Ohm
protective resistor
........................................................................................................................................................................
Operating temperature -15 °C up to +70 °C
Protection class IP68
........................................................................................................................................................................
Connection velocity 300 and 2400 Baud
Protocol content 13 monthly vloume values with date
13 flow rate maximum values with date
13 leckage alarm
Due date volume
Date and time
Alarm signal
– battery
– manipulation with date
– backflow with date
pulse value
momentary flow rate l/h or m3/h
flow rate calculation 1 min – 60 min
backflow volume
decimal place
Long and short telegram switchable
Write protection for important settings
Programming via MB Conf-software
.....................................................................................................................................................................
Primary/secondary addressing with wildcard
.....................................................................................................................................................................
Supported functions FCB-Bit, SND_NKE, REQ_UD2, SND_UD,
RSP_UD
Application for meters of type:
.................................................................................................................................................
PR6/PR6M/TPR6 PR7/PR7M/TPR7
V200 H4000
V210 H4200
S2000
C4000 bypass meter C4000 main meter
C3100 main meter
yellow
white
red
green
brown
black