Eltako FIUS65 User manual

Wireless signal generator pure white
glossy for single mounting 84x84x17mm
or mounting into the E-Design65 swit-
ching
system. Internal acoustic signal ge-
nerator for a minimum volume of 80dB.
Power supply 230V. Only 0.8 watt
standby loss. Smart Home sensor.
Up to 24 wireless universal pushbuttons,
wireless window contacts, window
handles, smoke detectors FRWB, water
sensors as well as motion sensors
FB65B and FBH65SB can be taught in.
Mounting over a 55mm switch box.
16mm over and 33mm into the box.
230V power supply terminals on the rear.
Startup:
After power supply is switched on, the
teach-in mode is activated automatical-
ly for 2 minutes if the memory is empty
(as-delivered state) or if the teach-in
mode was not blocked. Teach-in stand-
by is alerted by a short beep.
Teach in wireless pushbutton:
Universal pushbutton: tap briefly 3 times;
Direction pushbutton: tap briefly 4 times;
Doorbell pushbutton: tap briefly 5 times.
Wireless window contact: Close and
open the window briefly 3 times;
Wireless window handle sensor FFG7B:
(EEP: A5-14-09)
Wireless window/door contact FTKB-hg:
(EEP: A5-14-0A)
Wi l i FB65B
GB
30 065 067 - 1
Wireless indoor UP signal
generator
FIUS65
Only skilled electricians may install
this electrical equipment otherwise
there is the risk of fire or electric
shock!
Temperature at mounting location:
-20°C up to +50°C.
Storage temperature: -25°C up to +70°C.
Relative humidity:
annual average value <75%.
(EEP:
A5 14 0A)
Wireless motion sensor FB65B,
FBH65SB: (EEP: A5-07-01)
Smoke alarm and water sensor:
(EEP: A5-30-03)
Wireless water probe FWS81: Press
briefly the piston slide valve once.
GFVS: (EEP: A5-38-08) this automati-
cally switches on confirmation tele-
grams and blocks the teach-in mode.
After a pushbutton is taught in, it is
confirmed by a short acoustic signal;
the teach-in mode is active for a further
2 minutes.
To avoid teach-in by accident, the
teach-in mode is blocked automatically
2 minutes after the last teach-in if a
universal or a direction pushbutton was
previously taught in. This is alerted by
two short beeps.
Block teach-in mode immediately:
Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 3 times short and once long
(>2 seconds). Blocking is signalled by
two beeps.
Unblock teach-in mode:
Tap the pushbutton under the front panel
or an already taught-in direction push-
button 4 times short and once long
(>2 seconds).
Teach-in standby is signalled by a short
beep.
Clear memory content completely
(restore as-delivered state):
1. Switch the power supply off and on.
2. Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 8 times short and once
long (>2 seconds).
Clear is signalled by a short acoustic
signal.
3. Apply on 'Teach in wireless push-
button'.
Switch on/off confirmation telegrams:
1. Switch the power supply off and on.
2. Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 7 times short and once
long (>2 seconds).
ON is signalled by two short acoustic
signals.
OFF is signalled by a short acoustic
signal.
Deactivate acoustic signal generator
for alarm:
1. Switch the power supply off and on.
2. Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 5 times short and once
long (>2 seconds).
Deactivation is signalled by two short
acoustic signals.
Activate acoustic signal generator for
alarm (as-delivered state):
1. Switch the power supply off and on.
2. Tap the pushbutton under the front
panel or an already taught-in direction
pushbutton 6 times short and once
long (>2 seconds).
Activation is indicated by a short
acoustic signal.
Switch on alarm standby:
(Alarm readiness is always active for
smoke alarm and water sensors)
Press top of direction pushbutton. The
actuator is on alarm standby and
ON
is
signalled by a triple acoustic signal.
If a
monitored window is open or is opened
within 30 seconds after the alarm system
is enabled, a cyclical signal sounds imme-
diately indicating that the window is open.
The signal stops immediately the window
is closed
. After 30 seconds, incoming
telegrams are evaluated by taught-in
sensors and the alarm is triggered if ne-
cessary.
After a power failure, the actuator returns
automatically to alarm standby.
Confirmation telegram: (ORG5) 0x30 =
alarm standby ON
Switch alarm standby or alarm off:
Press bottom direction pushbutton or
press the pushbutton under the front
panel for 10 seconds and then release.
Alarm standby is switched off and OFF
is signalled by a short beep.
Confirmation telegram: (ORG5) 0x10 =
alarm standby OFF
When an alarm occurs, a beep sounds
1dThbtt
When
an
alarm
occurs
,
a
beep
sounds
every 1-second. The beep stops auto-
matically after 3 minutes
(the time starts
from zero at each incoming alarm tele-
gram) but an alarm confirmation telegram
(if activated) is
still sent every 1 second
for ON and every
9 seconds for OFF.
Switch alarm off:
Press bottom direction pushbutton or
press the pushbutton under the front
panel for 10 seconds and then release.
The alarm stops immediately.
When teaching in wireless window
contacts or window handles, the alarm
switches on after a response lag time of
10 seconds when a window is opened.
If you close the window, the alarm does
not stop automatically. Switch it off
using 'Press bottom direction pushbutton'.
After wireless window/door contacts
FTKB-hg are taught in, the intelligent
intrusion detector is active even if the
alarm system is disabled. An alarm
sounds when the window is opened in
locked and tilt position.
When teaching in FB65B or FBH65SB
motion sensors, the alarm switches on
after a response lag time of 10 seconds
when motion is detected.
Switch off the alarm using 'Press bottom
direction pushbutton'.
If a smoke detector FRWB or water
sensor is taught-in, the contact closes
immediately after receiving the alarm
telegram. In the event of an alarm end
telegram, the alarm does not stop auto-
matically. Switch it off using
'
Press bot-
tom direction pushbutton'.
If a doorbell pushbutton is pressed, an
acoustic signal is generated in an 2 se-
conds interval until the pushbutton is
released. (min. 3 times) If the doorbell
pushbutton stays pressed, the acoustic
signal stops after 1 minute. Alarm has
always priority over the doorbell.
When an universal pushbutton is
pressed, the alarm switches on after a
response lag time of 10 seconds. Switch
off the alarm using 'Press bottom direction
pushbutton'.
Teach in signal generator in actuators:
Press the pushbutton under the front
panel for 5 seconds and then release.
Send is signalled by two beeps.
Teach-in telegram: 0xE0400D80
Data telegram according to EEP:
A5-38-08
(ORG7) 0x01000008 = Alarm on
0x01000009 = Alarm off
Unblock teach-in mode for a wireless
actuator with FIUS65:
Press the pushbutton under the front
panel for 20 seconds and then release.
(ORG7) 0x01000028 = unblock
EnOcean wireless
Frequency 868.3MHz
Transmit power max. 10mW
Hereby, Eltako GmbH declares that the
radio equipment type FIUS65 is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration of
conformity is available at the following
internet address: eltako.com
Must be kept for later use!
Eltako GmbH
D-70736 Fellbach
Technical Support English:
Michael Thünte +49 176 13582514
thuente@eltako.de
Marc Peter +49 173 3180368
marc.peter@eltako.de
eltako.com
40/2019 Subject to change without notice.

Popular Security System manuals by other brands

X10 UX23A owner's manual

X10

X10 UX23A owner's manual

Bunker Hill Security 62368 Owner's manual & safety instructions

Bunker Hill Security

Bunker Hill Security 62368 Owner's manual & safety instructions

Lilin PRH-5218 instruction manual

Lilin

Lilin PRH-5218 instruction manual

First Alert First Alert CO400 user manual

First Alert

First Alert First Alert CO400 user manual

Blonder tongue NXG SYSTEM KIT quick guide

Blonder tongue

Blonder tongue NXG SYSTEM KIT quick guide

Risco WiComm Reference manual

Risco

Risco WiComm Reference manual

Ness Guardpost installation manual

Ness

Ness Guardpost installation manual

epiphan video Pearl Mini user guide

epiphan video

epiphan video Pearl Mini user guide

HomeMatic HM-Dis-EP-WM55 Installation and operating manual

HomeMatic

HomeMatic HM-Dis-EP-WM55 Installation and operating manual

LY-TECH LY-GSM200KIT user manual

LY-TECH

LY-TECH LY-GSM200KIT user manual

Technaxx TX-29 user manual

Technaxx

Technaxx TX-29 user manual

Visonic MCS-710 installation instructions

Visonic

Visonic MCS-710 installation instructions

Europlex SigNET 200 user guide

Europlex

Europlex SigNET 200 user guide

Westinghouse WSS55O8 instruction manual

Westinghouse

Westinghouse WSS55O8 instruction manual

TEXTCARE Main Sensor user manual

TEXTCARE

TEXTCARE Main Sensor user manual

Gemini 7590TK15 Installation and use manual

Gemini

Gemini 7590TK15 Installation and use manual

jablotron JA-60N manual

jablotron

jablotron JA-60N manual

DSC PC4020 - V3.3 manual

DSC

DSC PC4020 - V3.3 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.