Elyssa ABS-1000+ User manual

ABS-1000+
SECURITY ALARM
INSTRUCTION
MANUAL
PATENT #6130610
THANK YOU VERX MUCH FOR PURCHASING THIS
UNIT. FOR OPTIMUM PERFORMANCE, FOLLOW THE
INSTRUCTIONS INTHIS MANUAL CAREFULLY.

This is a self contained remote control operated motion activated
security device with a built-in P.I.R.with a 3600detection pattern
(Range depends on mounting height), L.E.D.indicator, and audible
arm/disarm tones. When armed, this unit willtrigger if there is
motion in the detection area. When triggered, the built-in 115dB
siren willsound for approximately 1 minutes and then reset -
provided there is no motion in the detection area (Ifmotion is still
present; the unit willcycle again and continue to do so until
disarmed). There are also input trigger terminals provided for
external sensing devices and auxilliaryoutput terminals to trigger
other devices. ARMING & DISARMING THE SYSTEM:
When arming the security system, you must wait a period of
approximately 1 minute for the sensor to set. At that time the area
is protected. This prevents false alarm~ during sensor setup and
allows time to leave the area. Allinputs (N/Oor N/C)are instant
afterarmingthe system. .
CODE SETTING:
There are 8 jumpers with a choice of (+)to center or (-)to center
for each. Alljumpers must be in one of these positions. Matchthe
jumpers in each remote with the jumpers on the main board.
FEATURES:.
-12 VOLTD.C. 1,000 mA AC/DC adaptor (INCLU~ED)
A plug-in 110VACto 12VDC power supply is included with
this unit. There is a a plug on the output of the AC/DCadaptor that
plugs directly into a jack on the connection board.
-REMOTE CONTROLS (INCLUDED)
2 programmable remote controls ~re provided.There are 2
buttons on the remote: Button #1 arms the unit, button #~
Disarms the unit. See "Code Setting" for coding instructions.
-AUXILLIARY TRIGGER INPUT (N/O)
This input is only active when alarm is
armed. A normally open dry contact input is
provided at terminals 4 &6 to allowthis system
to be activated by a normally open device such
as: Magnetic contact, panic switch, moisture
detector, pressure mat, etc.; this also allows the
unit to be triggered by any other system
providing a dry N/Orelay output. Unitwillreset
after approximately 2 minutes if circuit is re-
opened (Or unit is disarmed), if not the unit will
cycle again and continue to do so until contact
is broken or unit is disarmed.
AUX.TRIGGER
INPUT
4 5 6 7
8V G T 12V
V N R V
C DID
CG D

-AUXllLiARY TRIGGER INPUT (N/C NON-SUPERVISED)
This input is only active when alarm is armed.
A normally closed dry contact input is provided at
terminals 4 , 5 &S to allowthis system to be activated
by normally closed series circuit switches such as:
Magnetic door/window contacts, etc.. To use this
feature, a 10Kresistor (Provided) must be connected
to terminals 4 &6 and the closed series circuit must
Be connected to terminals 5 &6 (Ifnot using closed
circuit, resistor is NOTused). Unitwillreset after
approximately 2 minutes if circuit is restored (Or unit is
disarmed), if not the unit willcycle again and continue
to do so until contact is restored or unit is disarmed.
-AUXlllIARY RELAYOUTPUT
This unit provides a form "C" (N/O & N/C) dry contact output
rated at 5A1125Vat terminals 8(C), 9(N/C), & 10(N/0). This relay output
transfers contact when unit is triggered in armed status, and
retransfer when unit resets or is disarmed. This output may be used
to trigger auxilliary devices such as a phone dialer etc.
-AUXllLiARYVOLTAGEOUTPUT
A constant 12VDC output (Max. 500mA) is supplied at
te~minals 7(+) & 8(-)
-TAMPER SWITCH
There is a tamper switch mounted in the cabinet. Removing
the cover access plate when the system is armed willactivate the
tamper function and the alarm willsound. Unit willreset after
approximately 2 minutes if cover is replaced, if not the unit willcycle
again &continue to do so until cover is replaced or unit is disarmed.
-LE.D. INDICATOR .
An l.E.D. indicator light has been provided to monitor the
status of the system. On indicates ARMEDstatus, off indicates
DISARMEDstatus, and flashing indicates ALARMCONDITION.
-MOUNTING
Brackets ar~ provided for easy mounting. Sensor may be
positioned either vertically or horizontally depending on application.
-KEY SWITCH (OPTIONAL)
A key switch may be used to arm & disarm the system. A
maintained action (On/Off) key switch may be wired to term. 1 & 2.
-REMOTE l.E.D. INDICATOR (OPTIONAL)
A remote l.E.D. to indicate system status may be wired to
terminals 2(-) &3(+).This l.E.D. willlight when unit is armed and
turn off when unit is disarmed. .
-BATTERY CHARGER (OPTIONAL)
This unit has a charging circuit for a 12Voltsealed lead/Acid
AUX. TRIGGER
INPUT
4567
8V G T 12V
V N R V
C DID
C G D

type rechargeable battery. A 12Volt4 AmpIHourbattery (Not
supplied) is suggested, and is connected to terminals 11(-)&
12(+).Should A.C.input power fail,the battery willtake over
automatically.
-16 VOLT A.C. POWER* (OPTIONAL)
This unit may be powered by a 16 VAC/40VAtransformer
using terminals 13 & 14 .
*NOTE:YOU MAYONLYUSE ONE POWER SOURCE!
If using 16VAC, DO NOTattach the supplied 12V AC/DC adaptor,
as the unit will be damaged with both power sources attached.
AUX.TRIGGER IBATT IfACl
INPUT 12V ~
1 2 3 4 5 6 7 8 9 10 11 12 13 14
CODESETTING T S
_
12345678~~
+a a a a PT
o E C
-a a a a RH
FACTORY DEFAULT
CODE POSITIONS B- IB+ ACIAC
NOTE:When installing antenna, ~
HANDTIGHTENONLY! ~
Warning: Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
NOTE:This equipment has been tested and found to comply with the limits for a class B digital device,
pursuant to Part 15 of the DCC Rules. These limits are designed to provide reasonable protection against
harmful Interference In a residential Installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful
Interference to radio communications.
However, there is no guarantee that interference will not occur In a particular installation. It this equipment
does cause harmful Interference to radio or television reception, which can be determined by turning the
equipment off and on, the user Is encouraged to try to correct the interference by one or mo.., of the
following measures: -Reorient or relocate the antenna.
-Increase the separation between the equipment and receiver
-Connect the equipment to an outlet on a circuit different from that to which the receiver is connected
-Consult the dealer or an experienced RadlolrV technician for help
THE ABS-1000 SECURITY ALARM
CONTAINS THE FOLLOWING
ACCESSORIES:
1 -.(1pc.) ACto DCAdaptor(In.- 120VDC,out.- 12VDC)
2 - (2pc.) RemoteControllerWIBattery
6-(1 pc. ) Battery connection Wire
5-(4pc. ) Wall Mounting Bracket
4-(1pc. ) Antenna wI Screw Nut
3 - (1pc.) 10K Resistor (O.5W)
E~44 ~
Manufacturers and Importers
P.O.Box 138
Briarcliff Manor, NY 10510
Phone: (800) 441 -9122
Fax: (800) 335 -9533
KGL
ENE
Y D D
CNN
0I I
M C 0
8V GT12V
VNRV
CDID
CGD
Table of contents
Popular Security System manuals by other brands

Bosch
Bosch VSS7915/00T installation instructions

Fire Burglary Instruments
Fire Burglary Instruments LEGEND series owner's manual

Commell
Commell CMS-370Q Assemble guide & user's manual

X10
X10 VT38A owner's manual

GE Interlogix
GE Interlogix Security Simon 60-875 user guide

Meridian
Meridian Euro user manual

Sentryway
Sentryway CurveTrack System installation guide

Street Smart
Street Smart Code Encryptor II installation manual

GuardTronic
GuardTronic GTWAE7-4D Instruction

Cooper Security
Cooper Security i-on160EX installation guide

Electro Detectors
Electro Detectors EDA-Z1000 Operation manual

Whelen Engineering Company
Whelen Engineering Company Traffic Advisor TA837A installation guide