EmberGlo ES10 Series Quick guide

Installation and Service Instructions
Quality Designed for Proven Performance Printed in USA
8470 77
Specifi cations:
- 240 volts 60HZ AC 3200 watts 13.3 amp
or 208V 60HZ AC 2400 watts 11.6 amps
- Automatic timer operation (timer models only)
- Single shot operation
- End of cycle buzzer (10 seconds)
AVOID ERROR IN PARTS SELECTION. When ordering use
complete EMBERGLO Part Number and Description. Furnish
Model Number, Bill of Material Number and Serial Number (if
available) from the specifi cation plate found on the product.
IMPORTANT: Availability of parts as well as specifi cations are
subject to change without notice. Please consult factory for
item availability.
No Hood Installation Required: According to the Uniform
Mechanical Codes per the International Conference of Building
Offi cials Code EmberGlo Steamers do not require a separate
hood for vapor produced during operation of an EmberGlo
Steamer.
NOTE: EmberGlo ES10 Series Steamers use a cast aluminum
steam generator with two cast in electric heating elements.
For best steaming, the generator casting should contain some
mineral deposits. During fi nal inspection each generator casting
is pre-seasoned with a solution of baking soda and water. The
water marks and mineral deposits seen on a new generator
casting when the perforated food pan is removed is your
assurance that the unit has passed fi nal inspection test and will
readily produce steam.
SAFETY INFORMATION TERMS: The following terms are used to identify hazards, safety precaution of
special notations and have standard meanings throughout this manual. They are printed in all capital letters
using a bold type face as shown below, and preceded by the exclamation mark symbol. When you see the
safety alert symbol and one of the safety information terms as shown below, be aware of the hazard potential.
DANGER: Identifi es the most serious hazards which will result in severe personal injury or
death.
WARNING: Signifi es a hazard that could result in personal injury or death.
CAUTION: Identifi es unsafe practices which would result in minor personal injury or product and
property damage.
C
O
M
P
A
N
Y
R
E
G
I
S
T
E
R
E
D
EmberGlo
A Div of Midco® International Inc.
4140 West Victoria Street
Chicago, Illinois 60646
toll free 866.705.0515
tel 773.604.8700
fax 866.580.8700
web www.emberglo.com
e-mail [email protected]
Warranty
See the back of this manual for the full warranty.
This warranty does not apply to damages resulting from accident,
misuse, abuse or alteration.
No equipment may be returned without written authorization from
EmberGlo, A division of Midco International Inc., or Midco. Returned
goods must be shipped prepaid to the factory.
No equipment may be returned without written authorization from
MIDCO. Warranty card must be fi lled in and returned to EmberGlo (or
Midco) to validate warranty.
CAUTION: This manual contains suffi cient information for
installation of the EmberGlo Steamer in normal locations.
In the United States, installation must conform with local codes.
CODE COMPLIANCE IS THE SOLE RESPONSIBILITY OF
THE INSTALLER.
PURCHASER: Retain these instructions for future use. Post, in a
prominent location near the broiler, instructions for turning off gas valves
in case gas odor is detected and any other instructions as advised by
your local gas supplier.
CAUTION: Cooking equipment should be used in an
environment protected by an automatic fi re suppression system.
Consult the National Fire Protection Association NFPA Code 96 or the
latest edition of Standards for Installation of Equipment for Removal
of Smoke and Grease-Laden Vapors From Commercial Cooking
Equipment.
MADE in the USA
WARNING: Additions, changes, conversions and service
must be performed by an authorized EmberGlo representative or
service agency. Use only EmberGlo specifi ed and approved parts.
WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause property damage, injury
or death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable liquids and
vapors in the vicinity of this or any other appliance.
517
ES10 Series
Full Pan Size Food Steamers Automatic,
Program able Timer Operation Designed to
Operate with Tap Water - Direct Hookup
ES10PB: Manual Push Button
ES10T: Automatic, Programmable Timer Operation,
External Cycle Timer

EmberGlo A Division of Midco International Inc
MADE in the USA
2
ES10 Steamer Installation and Service
ES10 Steamers feature a 4″ deep full size steam table pan. The steamer lid is equipped with two
counter-balanced spring hinges and off ers a convenient choice of four locations for installing the
lid handle at the side or front of either front corner. Models Available for either manual or fully
automatic steaming.
Dimensions
Inches Centimeters
HEIGHT (lid closed) 9 3/4″ 24.77
HEIGHT (lid open 90 degrees) with lid handle mounted on
front corner of lid, projecting forward. 29″ 73.66
HEIGHT (lid open 90 degrees) with lid handle mounted on
side corner of lid, projecting to the side. 23″ 58.42
WIDTH 22 1/2″ 57.15
WIDTH with lid handle projecting to left or right side 28 1/2″ 72.39
DEPTH 22″ 55.88
____________________________________
Standard ES10 Steamers are designed for use with 208 VAC to 240 VAC, 4 (3 pole with ground)
wire, single phase, 60 Hz, electrical service. (See Figure 2). The generator casting contains two
heating elements, each rated for 1600 Watts. 13.3 amps, 120 Volts, 60 Hz. Models are available for
use on 50 Hz. (Non USA, Export only) electrical service. Call your distributor for more information.
Standard units are furnished with a six foot, four conductor (2 Hot/1 Neutral/1 Ground) cord. This
cord is equipped with a male twist-lock plug and matching loose female receptacle for convenient
fi eld installation.
____________________________________
Electrical. Female twist-lock receptacle, supplied loose with the steamer, should be installed by a
qualifi ed electrician. Refer to wiring diagrams. Figure 2.
NOTE: Female receptacle must be wired to assure that voltage to the individual heating elements
does not exceed 150 volts. (Circuits R-W and BK-W on Fig 1 and 2.) G terminal is wired to Ground
W terminal is wired to neutral. Protect circuit with a 15 amp double pole circuit breaker. In the
United States, Wiring to the Female receptacle must conform to local codes, or in the absence of
local codes, to the National Electrical Code ANSI/NFPA No. 70-1990, or latest edition. In Canada,
Wiring to the Female receptacle must conform to local codes, or in the absence of local codes,
to Canadian Electrical Code Part 1, CSA Standard C22.1. When choosing a location for the
steamer, be sure that there is adequate space over the unit to lift lid completely.
Water. Connect water hose assembly to water supply system. The supply end has a 1/8″ female
pipe fi tting and should be attached downstream of a shut-off valve. Steamer end of hose has a quick
connect fi tting which snaps onto mating fi tting on steamer. This hose fi tting has an automatic shut-off
valve that allows steamer to be disconnected without shutting off water supply. After connecting, turn
on water and check for leaks.
No Hood Installation Required: According to the Uniform Mechanical Codes per the International
Conference of Building Offi cials Code, EmberGlo Steamers do not require a separate hood for vapor
produced during operation.
Specifications
Electrical
Installation

EmberGlo A Division of Midco International Inc
8470 77 3
ES10 Steamer Installation and Service
Lid Angle Adjustment: To adjust the angle of the lid to 60° or 90°
1. With the lid closed, loosen and remove slotted screw. Set aside.
2. Remove lid stop by sliding it up and away from the steamer.
3. Adjust lid stop for desired position (60° or 90° open) and place on steamer.
4. Insert and tighten slotted screw.
See at Figure 1a, 1b and Figure 1c for correct orientation.
Factory default setting is 60°
____________________________________
1. Push power switch to ON position (switch lights up). Allow approximately 15 minutes for
steamer to reach operating temperature.
2. MODEL ES10PB:
Push STEAM button momentarily for each shot of steam desired. Water is sprayed into the
steam generator for as long as the button is depressed. If the STEAM button is depressed too
long or too often, fl ooding of the steam generator will result. A one second shot of water every
20 seconds is a good rule of thumb to avoid fl ooding.
3. MODEL ES10:
A.) For a single-shot steaming as with the ES10PB (above), fl ip the CYCLE/MANUAL switch
to the MANUAL side. Push the STEAM button for each shot of steam desired.
B.) For unattended steaming for up to 20 minutes, set the CYCLE/MANUAL switch to CYCLE.
Depress the STEAM button to activate a steaming cycle. Steaming will proceed according to
the timer settings.
Timers are confi gured as follows:
CYCLE TIME: Sets the total length of product cooking time, during which steam is
automatically supplied at adjustable intervals. At the end of the set time, steaming stops and
the buzzer sounds. Adjustable from 0.2 to 20 minutes.
STEAM SHOT “ON” TIME: Sets the amount of time that water is supplied to the steam
generator to create steam. Adjustable from 0.1 to 0.5 seconds.
STEAM SHOT “OFF” TIME: Sets the amount of the time between steam shots when no
steam is supplied. Adjustable from 6 to 18 seconds.
BUZZER DURATION: Sets the length of time that the buzzer will sound after automatic
steaming is completed. Adjustable from 0.1 to 10 seconds.
DELAY FROM LAST SHOT TO BUZZER: Sets the length of time between the last shot of
steam and the sounding of the buzzer. This dwell time allows absorption of steam into the
food. Adjustable from 0.1 to 30 seconds.
The adjustment features have been located within the steamer control box and made accessible
only with a screwdriver in order to discourage tampering or readjustments by unauthorized
personnel.
Operation
Figure 1a
Back of ES Series Steamer
60° Opening Position
Figure 1b
Back of ES Series Steamer
Lid Stop Reversed
90° Opening Position
1
2
1
2Item # Part # Description
1 HW1-099 #8-32 X 5/16″ Slotted
Pan Head Screw 18ss
2 1421-21 Lid Stop
90°
60°
Figure 1c

EmberGlo A Division of Midco International Inc
MADE in the USA
4
ES10 Steamer Maintenance - Daily and When Required
DANGER: Use extreme caution when adjusting timers. Bare wire terminals and/or bare
wires are exposed. Unplug male twist-lock plug or use extreme caution if steamer is plugged
in when making timer adjustments. Use an insulated or fi berglass screw driver.
IMPORTANT: KEEP LID CLOSED WHEN NOT IN USE. This keeps the food pan hot and reduces
condensation in the steam chamber. When steamer is fi rst installed, or when reconnecting water
hose, operate STEAM button several times to purge air from lines.
____________________________________
Maintenance
Food Pan and Grid on all models should be removed and washed with a detergent or run through
a dishwasher.
WARNING: Under no circumstances should the entire Steamer be run through a
dishwasher. If any of the switches or timers in electric control compartment get wet they can
malfunction. Never try to use a device that has been wet—replace it.
All exposed stainless steel surfaces should be wiped with a damp cloth or cleaned with a chlorine
free stainless steel cleaner. Rust spots can develop on stainless steel surfaces that are not cleaned
daily.
____________________________________
Generator: The cavity in the generator casting may accumulate lime and can be cleaned by
scraping or wire brushing. Do not remove all of this deposit since a thin coating improves steaming.
Water Nozzles: The water nozzles may be pulled out for cleaning. Clean small holes and inside of
nozzle tube. Located in the nozzle tube is a tool to be used for cleaning the holes in the water tube.
Water Inlet: If the nozzle socket tube through the generator is limed, remove plug at bottom and
push lime out with a wire or small rod.
Strainers: To wash strainer located in hose; fi rst, remove hose from steamer. Remove quick
connect fi tting from hose. Run water through hose in reverse direction. Return to original
connections.
There is a strainer in inlet of solenoid valve that normally does not require cleaning but under
extreme conditions may have to be removed and cleaned.
____________________________________
Maintenance
Daily
Maintenance
As Required
Operation Continued
Do not connect to a circuit operating
at more than 150 Volts to ground
Input
208V/240V/60 Hz
Neutral
Power
Switch
BK
Thermal Cut-off
BR
BK
BK
R/BK
W
BK
W
Heating
Element
1600W
Thermostat
120V
120V
GND
4
2
5
1
Buzzer
1425-00
Buzzer
Duration
2528-10
Hot Neut
23
Y
1M
BL
BL
2528-00
Buzzer
Delay
Y
Water
Solenoid
Valve
8402-26
7
6
Ext
Res
BL
Buzzer Timer
8406-63
14
COM NO
BL/W
1
2
3
4
1
2
3
4
1M
2528-20
Wiring for ES10 Steamer
with 101 or 102 control
OR
OR
610K
1M
BL/W
BR
BR 9
8
Ext Res
BR
321
Neut Hot Load
Shot Timer
On
Time
Off
Time
BL/W
BL/W
22K
100K
Y
NC
NO
COM
HOT
Neut
1
8
9
2
3
6
7
5
Ext Res
Cycle
Timer
1M
2528-40
Cycle
Time
SW
8406-64
W
BK
OR/BK
2528-30
R
W
R/BK
BL
BK
W
R/BK
W
R
BL
BL
1
2
3
4
1
2
3
4
36 6 3
25 5 2
1441
OR/BK
34
21
Steam
Button
R
BK
BK
Thermostat
Heating
Element
1600W
BK
Thermal
Cut-Off
R
R
Y
8406-62
Manual Cycle
8423-35
6
Figure 2: Wiring Diagram

EmberGlo A Division of Midco International Inc
8470 77 5
ES10 Steamer Trouble Shooting Chart
DANGER: READ AND UNDERSTAND THIS BULLETIN THOROUGHLY BEFORE
STARTING ANY TROUBLE SHOOTING. AN INADVERTENT SERVICE ERROR COULD RESULT
IN SEVERE PERSONAL INJURY OR DEATH. ONLY A TRAINED EXPERIENCED SERVICE
TECHNICIAN SHOULD ATTEMPT ANY REPAIR PROCEDURE.
Qualified service agencies are available at most locations—Refer to EmberGlo listing of
AUTHORIZED SERVICE AGENCIES included in Standard Equipment Catalog.
IMPORTANT: Defective wiring or loose connections can simulate the defects outlined below.
Check associated wiring before replacing a component.
1. UNIT DOES NOT HEAT—SWITCH ON, LIGHT OUT
A). Confi rm male twist-lock plug is plugged in and properly twisted (rotate clockwise).
B). Confi rm twist-lock receptacle is energized—reset breaker or repair house wiring.
WARNING: The following checks through 3. D. should be done with power cord
removed from receptacle.
C). Confi rm continuity in 4-conductor cord—replace if defective.
D). Confi rm continuity in double pole, single throw Power Switch, terminals 1-2 and 4-5 -
replace Power Switch if defective.
2. UNIT DOES NOT HEAT EVENLY OR STEAMS ONLY ON ONE END OF STEAM
GENERATOR CASTING—SWITCH ON, LIGHT ON.
A). Confi rm continuity of each of two Thermal Cut-off s— replace if defective.
B). Confi rm continuity of each of two Thermostats—replace if defective.
C). Confi rm continuity of each of two Heating Elements— replace entire Steam Generator
Casting if defective.
3. UNIT HEATS UP, BUT DOES NOT STEAM—NO WATER EVIDENT
A). Confi rm Manual Water Supply Valve is open and Water Hose Assembly is properly hooked
up. Refer to INSTALLATION-Water. A quick way to confi rm water line is operational is to
disconnect Water Hose at quick disconnect fi tting and push a small probe into quick disconnect
fi tting—water should fl ow freely.
B). Check and clean Water Nozzles, Water Inlet and Strainers.
Refer to MAINTENANCE AS REQUIRED.
C). Confi rm continuity of Steam Push Button Switch when depressed—replace if defective.
D). Confi rm continuity of water Solenoid Valve—replace if defective.
E). Water Solenoid Valve—Power Switch on, light on, confi rm 120 volts to GND on terminals
2 and 5 of Power Switch, both terminals of both Thermal Cut-off s, and terminal 3 of Square
Steam Button. With square Stem Button depressed, confi rm 120 volts to GND on terminal 4 of
Switch and blue lead terminal of Water Solenoid Valve. An audible click should be heard when
Valve is energized—if no click, jumper white lead terminal of Valve to GND. If click is heard with
jumper attached, white neutral wires are faulty from Valve thru both heater elements to neutral
on 4-conductor cord. Locate fault and repair. If no click, Water Solenoid Valve is defective and
should be replaced.
4. UNIT FLOODS—SELECTOR SWITCH TO MANUAL; SQUARE STEAM PUSH BUTTON NOT
DEPRESSED.
A. Water Solenoid Valve seat is dirty and valve cannot close completely or is defective clean or
replace as required.
WARNING: The following checks through Section 5 part B should be done with
power cord plugged in and properly twisted. Use extreme care as bare wire terminals
and/or bare wires are exposed.
5. UNIT FLOODS—SELECTOR SWITCH TO CYCLE
A. Same as 4.A.
B. STEAM SHOT, OFF TIME set for too frequent shots—refer to OPERATION 3B.
____________________________________
Trouble
Chart

EmberGlo A Division of Midco International Inc
MADE in the USA
6
ES10 Steamer Heating and Cooking Guide
The suggestions are made only to help the operator get started. Since each location will have
diff erent portions and diff erent requirements, each operator must determine his own operation
habits. The manual model is generally operated with one or two shots at the start. If additional heat
is required, operate up to three shots per minute. Since the product to be heated can only absorb
heat at a certain rate, do not over steam, exceeding three shots per minute will usually not improve
performance. The timer model controls the number of steam injections per minute. The unit can be
used as a warmer or cooker. When the product heating time is established, set the timer to obtain
the same results.
Breads Refrigerated Frozen
Bread ....................................................................... 1 to 2 shots of steam 2 min
Bagels ....................................................................... 1 to 2 min 3 to 4 min
Croissant ....................................................................... 15 seconds
Muffi n ....................................................................... 1-2 shots of steam
Pastries ....................................................................... 1 to 2 min 3 to 4 min
Tamales ....................................................................... 5 min 10 min
Tortillas ....................................................................... 1 shot of steam 10 seconds
Eggs
Soft Boiled ................................................................... 6 min
Poached ....................................................................... 3 min
Scrambled (dz) ......................................................... 5 min
Meat
Bratwurst ....................................................................... 8 min 16 min
Breakfast sausage ......................................................... 8 min 14 min
Chicken breast (lg) ........................................................ 15 min 25 to 30 min
Chicken breast (precooked) .......................................... 5 min 15 min
Deli meats .................................................................... 2 to 3 min
Hamburger (precooked)................................................. 4 min 4 min
Hot dogs ....................................................................... 4 min 8 min
Italian sausage .............................................................. 4 min 8 min
Ribs (precooked) ........................................................... 10 min 18 min
Noodles and Rice
Macaroni (2 qt. cooked, 1 pt. water, 2 oz. oil) ................ 5 min
Egg Noodles (2 qt. cooked, 1 pt. water, 2 oz. oil) .......... 6 to 7 min
Rice (precooked) ......................................................... 5 min 8 to 10 min
Spaghetti (2 qt. cooked, 1 pt. water) ............................. 5 min
Vegetables
Artichokes ........... ......................................................... 25 to 30 min 50 min
Asparagus ..................................................................... 10 min 14 min
Brussels ....................................................................... 15 min 18 min
Broccoli ....................................................................... 10 min 12 min
Carrots sliced ................................................................ 4 min 8 min
Carrots whole baby (2 lb) .............................................. 15 to 20 min
Caulifl ower ..................................................................... 12 min 16 min
Corn on the cob ............................................................. 3 min 5 min
Fennel ............................................................................ 10 min
Green beans .................................................................. 4 min 8 min
Pea pods ....................................................................... 6 min 9 min
Peas .............................................................................. 5 min 8 min
Potatoes 8 whole (3 oz each) ........................................ 20 min
Potatoes mashed (2 qt) ................................................. 8 min
Squash, Acorn 4 (8 oz each) ......................................... 12 to 20 min
Squash, Zucchini -sliced frozen (1b) ............................. 10 Min
Seafood
Large clams ................................................................... 4 min 8 min
King crab ....................................................................... 8 min 12 min
Snow crab ...................................................................... 6 min 10 min
Fish fi lets ....................................................................... 6 min 8 to 10 min
Lobster 8 oz Tails ......................................................... 8 min 14 to 16 min
Scallops ......................................................................... 5 min 8 to 10 min
Shrimp ........................................................................... 4 min 6 min
Heating and
Cooking Guide

EmberGlo A Division of Midco International Inc
8470 77 7
Accessories
ES10 Steamer Accessories
Accessories for Steamers
Increase your effi ciency with accessories made just for your steamer.
Steaming Basket Sets and Steaming Racks
Take full advantage of your EmberGlo Steamer with specially designed stainless steel Steaming
Basket Sets and Steaming Racks. All sets and racks come with an easy to use removable handle.
Increase your effi ciency by dual steaming diff erent items in separate baskets. Freshen or heat up
tortillas and pita bread in a Tortilla Steaming rack.
Half Pan Size Basket - 5608-72 Tortilla Rack
Quarter Pan Size Basket (2 pk) - 5608-73 (for Tortillas & Pitas) - 5682-60
3 in One Basket Set (1 Half and 2 Quarters) - 5608-70
(Basket Sets come with a Handle)
Cleaning Brush Egg Poacher
Scrapping off mineral build up is easy with our A quick and healthy way to serve
sturdy stainless steel Generator Cleaning Brush. poached eggs.
Cleaning Brush - 8450-62 4 Cup Egg Poacher - 2070610
6 Cup Egg Poacher - 2070615
5682-60 Tortilla/Pita Rack 10 1/4″ L x 7 5/8″ W x 3 5/32″ H
5608-70 Three in 1 Basket Kit w/ Handle 10 2/3″ L x 8 1/8″ W x 3″ H
5608-72 1/2 Size Basket w/ Handle 10 2/3″ L x 8 1/8″ W x 3″ H
5608-73 Two of 1/4 Size Basket w/ Handle 7 7/8″ L x 5 1/8″ W x 3″ H
2070610 4 Cup Egg Poacher 9″ L x 9″ W x 3″ H
2070615 6 Cup Egg Poacher 12 3/4″ L x 12 5/8″ W x 3″ H
8450-62 Steamer Cleaning Brush 7 3/4″ L

EmberGlo A Division of Midco International Inc
Warranty
Midco® International Inc Limited Warranty Policy
Exclusions Terms, Customer Requirements and Instructions
All claims should be fi led through Warranty Central.
Call factory for information (773 604 8700)
Only Authorized Service Providers are authorized to provide Limited Warranty service on all EmberGlo®, a Division of Micdo® International Inc., food
equipment as described under and Midco® International Limited Warranty Policy. A list of providers can be found on our web site: www.emberglo.com
Provisions:
In lieu of an implied warranty, all repairs and replacement parts furnished under our Limited Warranty shall be f.o.b. point of distribution, but the
owner must pay the necessary freight, delivery and labor costs involved when required. Any Federal, State or Local taxes are also extra. This Limited
Warranty is eff ective for a period of 90 days from the date of original installation. If the product registration cards are returned within those 90 days,
the warranty will be one year from date of installation. EmberGlo® Char Broilers and EmberGlo® Electric Food Preparation Equipment manufactured
by Midco International, sold under the EmberGlo® trademark, are guaranteed to be free from defect in material and workmanship under normal use
and service for a period of 90 days from the date of original installation or for 1 (one) year when the registration card is returned within a reasonable
time after the date of original installation. Midco’s obligation under this Limited Warranty Policy shall be limited to repairing or replacing, at our option,
any part of said equipment which Midco examination shall disclose to its satisfaction to be thus defective.
Exclusions:
This Limited Warranty Policy does not apply to damages resulting from accident, misuse, abuse or alteration, nor does it apply to limed steam
generators, nor does it apply to any consequential damages. Most geographical areas require the use of distilled or demineralized water. Tap water
is permissible only with ES Series Steamers. Nor does it apply to Barbriq’s®, briquettes, or rods used in gas broilers. Midco’s obligation will be the
replacement of the product or parts removed.
Terms:
Under the terms of this Limited Warranty Policy, models considered portable (devices with cords and plug caps such as EmberGlo Steamers) must
be taken or returned to the nearest service provider, transportation prepaid, returned transportation collect. Non-portable units with permanent wiring
will be serviced on the customer’s premises. Under these terms, Midco agrees, within the terms of this Limited Warranty period, to make all repairs
at no charge by the authorized service provider. Labor and mileage charges submitted by any other provider not authorized will be the responsibility
of the customer.
Customer Requirements:
All charges related to repairs made after the 90 day or one (1) year, when the registration card is returned within a reasonable time after the date of
original installation, during the Limited Warranty period will be the responsibility of the customer unless the registration card has been properly fi lled
out and returned to Midco International Inc. The product registration information is located on the product I.D. plate.
If a part is defective due to workmanship or materials and is removed from the product within the applicable warranty period and returned to Midco
in accordance with the following procedure described, Midco will, at its option, either repair or replace the part.
Call the factory for Instructions on returned goods.
No equipment may be returned without written authorization from MIDCO. Returned goods must be shipped prepaid to the factory.
WARNING: Improper installation and use of this product could result in personal or property injury.
MADE in the USA
Keep for your records
Gas Broiler Electric Broiler Steamer Accessory
Model Number
Serial Number
Installation Date
Purchased from - Name:
Address
City, State, Zip
TO VALIDATE WARRANTY:
FILL OUT THE FORM ON THE NEXT PAGE
RETURN TO EMBERGLO
8
ES10 Steamer Warranty
EmberGlo A Division of Midco International - 4140 West Victoria Street - Chicago, Illinois 60646
toll free: 866 705 0515 - tel: 773.604.8700 - fax: 866.580.8700 - web: www.emberglo.com - e-mail: [email protected]
Printed in USA
517
8470 77
ISO
9001
C
O
M
P
A
N
Y
R
E
G
I
S
T
E
R
E
D

Warranty
EmberGlo A Division of Midco International Inc
8470 77 9
Warranty
Midco® International Inc Limited Warranty Policy
Exclusions Terms, Customer Requirements and Instructions
All claims should be fi led through Warranty Central. Call factory for information (773 604 8700)
Fill out form and fax to 773 604 4070 or copy and mail to: EmberGlo A Division of Midco International
4140 West Victoria Street
Chicago, Illinois 60646
Date of Purchase
End User Name
Company Name
Street & Apt. No.
City, State, Zip
Email Address
Web Address
Telephone
Fax
Gas Broiler Electric Broiler Steamer Accessory
Model Number
Serial Number
Installation Date
Purchased from - Name:
Address
City, State, Zip
ES10 Steamer Warranty

EmberGlo A Division of Midco International - 4140 West Victoria Street - Chicago, Illinois 60646
toll free: 866 705 0515 - tel: 773.604.8700 - fax: 866.580.8700 - web: www.emberglo.com - e-mail: [email protected]
Printed in USA
8470 77
ISO
9001
C
O
M
P
A
N
Y
R
E
G
I
S
T
E
R
E
D
517
EmberGlo A Division of Midco International Inc.
Attn: Warranty Department
4140 West Victoria Street
Chicago, Illinois 60646
PLACE
STAMP
HERE
This manual suits for next models
4
Table of contents
Other EmberGlo Electric Steamer manuals
Popular Electric Steamer manuals by other brands

Market Forge Industries
Market Forge Industries MPS-3E owner's manual

Market Forge Industries
Market Forge Industries 3500 SERIES owner's manual

Bauknecht
Bauknecht ECTM 9145 Instructions for use

Unold
Unold MINI ALLROUND Instructions for use

Market Forge Industries
Market Forge Industries TS-3E Parts and service manual

Morphy Richards
Morphy Richards Intellisteam instructions