manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Accessories
  8. •
  9. Emerson Rosemount 0065 User manual

Emerson Rosemount 0065 User manual

Quick Start Guide
00825-0200-2654, Rev BE
June 2016
Rosemount™0065/0185 Sensor Assembly
June 2016
2
Quick Start Guide
NOTICE
This guide provides basic guidelines for Rosemount 0065 and 0185 Sensor models. It does not
provide instructions for configuration, diagnostics, maintenance, service, troubleshooting,
Explosion-proof, Flameproof, or intrinsically safe (I.S.) installations.
If the Rosemount 0065 or 0185 Sensor was ordered assembled to a Rosemount Temperature
Transmitter, see the appropriate Quick Start Guide for information on configuration and
hazardous locations certifications.
WARNING
Explosions could result in death or serious injury.
Installation of this transmitter in an explosive environment must be in accordance with the
appropriate local, national, and international standards, codes, and practices.
Conduit/cable entries
Unless marked, the conduit/cable entries in the transmitter housing use a 1/2–14 NPT thread
form. Entries marked “M20” are M20 ⫻1.5 thread form. On devices with multiple conduit
entries, all entries will have the same thread form. Only use plugs, adapters, glands, or
conduit with a compatible thread form when closing these entries.
Contents
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Sensor Assembly Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Quick Start Guide
3
June 2016
Wiring Diagrams
Figure 1. Rosemount Series 65 RTD Lead Wire Configuration
Note
For 3-wire systems use one white and two red leads. Do not connect the white leads. Insulate or
terminate the unused white lead in a manner that prevents shorting to the ground. For 2-wire
systems, connect both sets of leads.
Flying leads and spring-loaded adapter (termination codes 0, 1, or 3 only)
Single element Dual element
Terminal block (termination code 2 and 4)
Single element Dual element
Red
White
White
Red
Red
Red
Green
Blue
Blue
Black
3
4
1
6
Red
Red
White
White 6
1
3
4
123
4
5
6
4
5
6
1
2
3Red
Red
White
Red
Red
White
June 2016
4
Quick Start Guide
Figure 2. Rosemount Series 185 Thermocouple Lead Wire Configuration
Note
To distinguish the two sensors in Rosemount Dual 185 Sensors (flying lead or spring loaded styles),
the lead wires of one sensor will be longer than the other sensor.
Thermocouple terminal block
Single element Dual element
Table 1. Rosemount Series 185 Thermocouple Characteristics
Type Alloys
(wire color) Sheath material Temp. range (°C)
Limits of error
interchangeability
DIN EN 60584-2
Tolerance
class
JFe (+ black),
CuNi (- white) 1.4541 (321 SST) -40 to 375, 375 to 750 1.5 °C, 0.004 t 1
KNiCr (+ green),
NiAl (- white) 2.4816 (Alloy 600) -40 to 375, 375 to 1000 1.5 °C, 0.004 t 1
NNiCrSi (+ pink),
NiSi (- white) 2.4816 (Alloy 600) -40 to 375, 375 to 1000 1.5 °C, 0.004 t 1
ENi-Cr (+violet),
Cu-NI (-white) 1.4541(321 SST) -40 to 375, 375 to 800 1.5 °C, 0.004t 1
TCu (+brown),
Cu-Ni (-white) 1.4541 (321 SST) -40 to 125, 125 to 350 0.5 °C, 0.004t 1
3
1
1 (+)
3(-)
13
46
4(+)
6(-)
1(+)
3(-)
Quick Start Guide
5
June 2016
Sensor Assembly Dimensions
Sensor assembly without thermowell
Rosemount
248
Rosemount
644
Head or field
mount transmitters
Rosemount IP68 or
IP65 connection
heads
Sensor with flying leads,
terminal block, or spring-loaded
adapter
Extensions
Rosemount 644 with
LCD display meter
Rosemount
3144
40 mm 25 mm
L
16 mm
N★★
N★★
N★★
L
L
★★ N dimension measures from thread
engagement point.
11 mm
11 mm
June 2016
6
Quick Start Guide
Tubular thermowell sensor assembly
Rosemount
248
Rosemount
644
Rosemount IP68 or
IP65, connection
heads
Sensor with flying leads or
terminal block
Threaded and flanged tubular
thermowells
Rosemount 644 with
LCD display meter
40 mm
Head or field
mount transmitters
N
U
U
N
25 mm
NAMUR NAMUR
★★ For straight threading, N
dimension references bottom
of hex. For tapered threading,
N dimension references thread
engagement point (bottom of
thread).
U
N
U
GB GN
★★ ★★
★★
Quick Start Guide
7
June 2016
Barstock thermowell sensor assembly
Sensor with flying leads,
terminal block, or
spring-loaded adapter
Weld-in,
threaded or
flanged
barstock
thermowells
* The Rosemount 644 is available
with or without a LCD display.
Rosemount
3144
Stand-alone
extensions
Rosemount
248
Rosemount
644
Rosemount IP 68
or IP 65
connection heads
Rosemount 644 with
LCD display meter
40 mm
Head or field
mount transmitters
11mm
L
11 mm
16 mm
N★★
11 mm
11 mm
60 mm★★★
U
U
U
60
mm
L
L
★★ N dimension measures from
thread engagement point.
★★★ This dimension is 80 mm for
Class 1500 and Class 2500
flanges.
N★★
N★★
25 mm
T
U
40 mm
U
60
mm
June 2016
8
Quick Start Guide
Product Certifications
European Directive information
A copy of the EC Declaration of Conformity can be found at the end of the Quick
Start Guide. The most recent revision of the EC Declaration of Conformity can be
found at EmersonProcess.com/Rosemount.
Hazardous locations certifications
USA
E5 FM Explosion-proof and Dust-Ignition-proof
Certificate: 0R7A2.AE
Standards: FM Class 3600: 2011; FM Class 3611: 2004; FM Class 3615: 2006; FM Class
3810: 2005; ANSI/NEMA®- 250: 1991
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; T6(–50 °C ≤Ta≤
+155 °C); Type 4X
Canada
E6 CSA Explosion-proof and Dust-Ignition-proof
Certificate: 1063635
Standards: CSA C22.2 No. 0-M91; CSA C22.2 No. 25-1966; CSA C22.2 No. 30-M1986;
CSA C22.2 No. 94-M91; CSA C22.2 No. 142-M1987; CSA C22.2 No.
213-M1987
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; CL I, Div 2, GP A, B, C, D;
(-50 °C ≤Ta≤+85 °C)
Europe
E1 ATEX Flameproof
Certification number: FM12ATEX0065X
Standards: 60079-0:2012; EN60079-1:2007
Markings: II 2 G Ex d IIC T6...T1 Gb, T6(-50 °C ≤Ta≤ +40 °C), T5...T1 (-50 °C ≤ Ta≤
+60 °C), 1180
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature
on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
Quick Start Guide
9
June 2016
I1 ATEX Intrinsic Safety
Certificate: IBExU03ATEX1066X
Standards: EN 60079-0:2012, EN 6079-11:2012, EN 60079-26:2007
Markings: II 1 G Ex ia IIC T6; II 1/2 G Ex ia IIC T6; II 2 G Ex ia IIC T6; 1180
Special Conditions for Safe Use (X):
1. The installation and the operation of the temperature sensors has to be carried out
according to the requirements of the operating instructions.
2. The maximum permissible temperatures of the medium are dependent on the
electric output of the supply in case of failure.
3. With maintenance of the collar-tube distance have to be guaranteed the maximum
permissible ambient temperatures.
4. The maximum ambient temperature for use in Category 1 G is 60 °C.
N1 ATEX Type n
Certificate: BAS00ATEX3145
Standards used: EN 60079-0:2012, EN 60079-15:2010
Markings: II 3 G Ex nA IIC T5 Gc (-40 °C ≤Ta≤+70 °C); 1180
ND ATEX Dust
Certification number: FM12ATEX0065X
Standards Used: EN 60079-0:2012; EN 60079-31: 2009
Markings: II 2 D Ex tb IIIC T130 °C Db (-40 °C ≤Ta≤ +70 °C); 1180
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option “N”.
6. Care shall be taken by the end user to ensure that the external surface temperature
on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
International
E7 IECEx Flameproof
Certificate: IECEx FMG 12.0022X
Standards: IEC60079-0:2011, IEC60079-1:2007-04
Markings: Ex d IIC T6...T1 Gb, T6(-50 °C ≤Ta≤+40 °C), T5…T1(-50 °C ≤Ta≤+60 °C)
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
June 2016
10
Quick Start Guide
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature on
the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
Brazil
E2 INMETRO Flameproof
Certificate: UL-BR 13.0535X
Standards: ABNT NBR IEC 60079-0: 2008 + Corrigendum 1:2011; ABNT NBR IEC
60079-1: 2009 + Corrigendum 1:2011
Markings: Ex d IIC T6...T1 Gb IP66W (-40 °C ≤Ta≤+65 °C)
Special Conditions for Safe Use (X):
1. See product description for ambient temperature limits and process temperature
limits.
2. Guard the LCD display cover against impact energies greater than 4 joules.
3. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
Japan
E4 Japan Flameproof (0065 only)
Certificate: TC17226
Markings: Ex d IIC T6;(-20 °C ≤Ta≤+65 °C); Process Temperature: -20 °C to +85 °C
Special Condition for Safe Use (X):
1. The wiring shall be suitable for a temperature over 80 °C.
EAC – Belarus, Kazakhstan, Russia
EM Technical Regulation Customs Union (EAC) Flameproof
Certificate: RU C-US.GB05.B.00289
Markings: 1Ex d IIC T6…T1 Gb X
Special Condition for Safe Use (X):
1. See certificate for special conditions.
IM Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate: RU C-US.GB05.B.00289
Markings: 0Ex ia IIC T6 Ga X; Ga/Gb Ex ia IIC T6 X; 1Ex ia IIC T6 Gb X
Special Condition for Safe Use (X):
1. See certificate for special conditions.
Combinations
KD Combination of E1, E5, and E6
K1 Combination of E1, I1, N1, and ND
KM Combination of EM and IM
Quick Start Guide
11
June 2016
Figure 3. Rosemount 0065 Sensor Assembly Declaration of Conformity
June 2016
12
Quick Start Guide
c
Quick Start Guide
13
June 2016
June 2016
14
Quick Start Guide

ᴹ
China RoHS
㇑᧗⢙䍘䎵䗷ᴰབྷ⎃ᓖ䲀٬Ⲵ䜘Ԧරࡇ㺘
Rosemount 0065/0185

List of Rosemount 0065/0185
Parts with China RoHS Concentration above MCVs
䜘Ԧ〠
Part Name
ᴹᇣ⢙䍘䍘Hazardous Substances
䫵
Lead
(Pb)
⊎
Mercury
(Hg)
䭹
Cadmium
(Cd)
ޝԧ䬜䬜
Hexavalent
Chromium
(Cr +6)
ཊⓤ㚄㚄㤟
Polybrominated
biphenyls
(PBB)
ཊⓤ㚄㚄㤟䟊
Polybrominated
diphenyl ethers
(PBDE)
⭥ᆀ㓴Ԧ
Electronics
Assembly
X
O
O
O
O
O
༣փ㓴Ԧ
Housing
Assembly
O
O
O
X
O
O
Րᝏಘ㓴Ԧ
Sensor
Assembly
X
O
O
O
O
O
ᵜ㺘Ṭ㌫׍ᦞ
SJ/T11364
Ⲵ㿴ᇊ㘼ࡦ֌
This table is proposed in accordance with the provision of SJ/T11364.
O:
᜿Ѫ䈕䜘ԦⲴᡰᴹ൷䍘ᶀᯉѝ䈕ᴹᇣ⢙䍘Ⲵ䟿൷վҾ
GB/T 26572
ᡰ㿴ᇊⲴ䲀䟿㾱≲
O: Indicate that said hazardous substance in all of the homogeneous materials for this part is below the limit requirement of
GB/T 26572.
X:
᜿Ѫ൘䈕䜘Ԧᡰ֯⭘Ⲵᡰᴹ൷䍘ᶀᯉ䟼ˈ㠣ቁᴹа㊫൷䍘ᶀᯉѝ䈕ᴹᇣ⢙䍘Ⲵ䟿儈Ҿ
GB/T 26572
ᡰ㿴ᇊⲴ䲀䟿㾱≲
X: Indicate that said hazardous substance contained in at least one of the homogeneous materials used for this part is above
the limit requirement of GB/T 26572.
Quick Start Guide
15
June 2016
Global Headquarters
Emerson Process Management
6021 Innovation Blvd
Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
[email protected]
North America Regional Office
Emerson Process Management
8200 Market Blvd.
Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
RMT-NA.R[email protected]
Latin America Regional Office
Emerson Process Management
1300 Concord Terrace, Suite 400
Sunrise, FL, 33323, USA
+1 954 846 5030
+1 954 846 5121
[email protected]
Europe Regional Office
Emerson Process Management Europe GmbH
Neuhofstrasse 19a P.O. Box 1046
CH 6340 Baar
Switzerland
+41 (0) 41 768 6111
+41 (0) 41 768 6300
[email protected]
Asia Pacific Regional Office
Emerson Process Management Asia Pacific Pte Ltd
1 Pandan Crescent
Singapore 128461
+65 6777 8211
+65 6777 0947
Enquiries@AP.EmersonProcess.com
Middle East and Africa Regional Office
Emerson Process Management
Emerson FZE P.O. Box 17033,
Jebel Ali Free Zone - South 2
Dubai, United Arab Emirates
+971 4 8118100
+971 4 8865465
RFQ.RMTMEA@Emerson.com
Standard Terms and Conditions of Sale can be found at:
Emerson.com/en-us/pages/Terms-of-Use.aspx.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
Rosemount and Rosemount logotype are trademarks of Emerson Process
Management.
All other marks are the property of their respective owners.
© 2016 Emerson Process Management. All rights reserved.
Quick Start Guide
00825-0200-2654, Rev. BE
June 2016
00825-0200-2654

Other manuals for Rosemount 0065

2

This manual suits for next models

1

Other Emerson Accessories manuals

Emerson Net Safety SC311 User manual

Emerson

Emerson Net Safety SC311 User manual

Emerson Rosemount 550pH User manual

Emerson

Emerson Rosemount 550pH User manual

Emerson AVENTICS SM6-AL User manual

Emerson

Emerson AVENTICS SM6-AL User manual

Emerson Rosemount 328A User manual

Emerson

Emerson Rosemount 328A User manual

Emerson EASYHEAT MSA-1 Installation instructions

Emerson

Emerson EASYHEAT MSA-1 Installation instructions

Emerson Rosemount 3051S Series User manual

Emerson

Emerson Rosemount 3051S Series User manual

Emerson Rosemount 398R User manual

Emerson

Emerson Rosemount 398R User manual

Emerson Rosemount 3200HP User manual

Emerson

Emerson Rosemount 3200HP User manual

Emerson Rosemount 404 User manual

Emerson

Emerson Rosemount 404 User manual

Emerson Fisher 249VS User manual

Emerson

Emerson Fisher 249VS User manual

Emerson Rosemount 389 User manual

Emerson

Emerson Rosemount 389 User manual

Emerson AVENTICS SM6 User manual

Emerson

Emerson AVENTICS SM6 User manual

Emerson Rosemount 228 User manual

Emerson

Emerson Rosemount 228 User manual

Emerson AVENTICS ST6 User manual

Emerson

Emerson AVENTICS ST6 User manual

Emerson ER40 User manual

Emerson

Emerson ER40 User manual

Emerson Rosemount 3300HT User manual

Emerson

Emerson Rosemount 3300HT User manual

Emerson MICROMOTION CNG050 User manual

Emerson

Emerson MICROMOTION CNG050 User manual

Emerson Rosemount 385 User manual

Emerson

Emerson Rosemount 385 User manual

Emerson Rosemount 214C User manual

Emerson

Emerson Rosemount 214C User manual

Emerson Rosemount User manual

Emerson

Emerson Rosemount User manual

Emerson Rosemount Hx338+ User manual

Emerson

Emerson Rosemount Hx338+ User manual

Emerson Rosemount 499AOZ User manual

Emerson

Emerson Rosemount 499AOZ User manual

Emerson Micro Motion T Series User manual

Emerson

Emerson Micro Motion T Series User manual

Emerson Micro Motion ELITE CMF200A User manual

Emerson

Emerson Micro Motion ELITE CMF200A User manual

Popular Accessories manuals by other brands

TOTALINE P474-0401-1RF/REC quick guide

TOTALINE

TOTALINE P474-0401-1RF/REC quick guide

Hytronik HMW39/RF Installation and instruction manual

Hytronik

Hytronik HMW39/RF Installation and instruction manual

Honeywell RPW211 Mounting instruction

Honeywell

Honeywell RPW211 Mounting instruction

Homelite 19396 instruction sheet

Homelite

Homelite 19396 instruction sheet

Essence Smartcare Care@Home MDsense Getting started

Essence Smartcare

Essence Smartcare Care@Home MDsense Getting started

Texas Instruments OPT3006EVM user guide

Texas Instruments

Texas Instruments OPT3006EVM user guide

Aeotec MULTISENSOR 6 user guide

Aeotec

Aeotec MULTISENSOR 6 user guide

Banner iVu Plus TG Series instruction manual

Banner

Banner iVu Plus TG Series instruction manual

Dragino LWL02 user manual

Dragino

Dragino LWL02 user manual

Baumer UNDK 10N8914/S35A manual

Baumer

Baumer UNDK 10N8914/S35A manual

Elsner Sewi KNX TH-L-Pr Installation and adjustment manual

Elsner

Elsner Sewi KNX TH-L-Pr Installation and adjustment manual

solpro Gemini user manual

solpro

solpro Gemini user manual

AEM LAMBRECHT meteo PROFESSIONAL Wind Direction user manual

AEM

AEM LAMBRECHT meteo PROFESSIONAL Wind Direction user manual

Rinstrum 5100 Communications manual

Rinstrum

Rinstrum 5100 Communications manual

Summit Treestands Viper Ultra SD manual

Summit Treestands

Summit Treestands Viper Ultra SD manual

Rohde & Schwarz NRP-Z51 operating manual

Rohde & Schwarz

Rohde & Schwarz NRP-Z51 operating manual

Seifert SlimLine Pro KG 8412 instruction manual

Seifert

Seifert SlimLine Pro KG 8412 instruction manual

LED Group Robus RDLHRV-HMW32S instruction manual

LED Group

LED Group Robus RDLHRV-HMW32S instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.