manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Accessories
  8. •
  9. Emerson Rosemount 0065 User manual

Emerson Rosemount 0065 User manual

Other manuals for Rosemount 0065

2

This manual suits for next models

1

Other Emerson Accessories manuals

Emerson Micro Motion H Series User manual

Emerson

Emerson Micro Motion H Series User manual

Emerson Rosemount 3051S Series User manual

Emerson

Emerson Rosemount 3051S Series User manual

Emerson Rosemount 0065 User manual

Emerson

Emerson Rosemount 0065 User manual

Emerson AVENTICS ST6 User manual

Emerson

Emerson AVENTICS ST6 User manual

Emerson Rosemount 398R User manual

Emerson

Emerson Rosemount 398R User manual

Emerson Micro Motion ELITE CMF200A User manual

Emerson

Emerson Micro Motion ELITE CMF200A User manual

Emerson Rosemount 3200HP User manual

Emerson

Emerson Rosemount 3200HP User manual

Emerson 210-2000 User manual

Emerson

Emerson 210-2000 User manual

Emerson EASYHEAT MSA-1 Installation instructions

Emerson

Emerson EASYHEAT MSA-1 Installation instructions

Emerson ER40 User manual

Emerson

Emerson ER40 User manual

Emerson Rosemount 396 User manual

Emerson

Emerson Rosemount 396 User manual

Emerson Rosemount 396PVP User manual

Emerson

Emerson Rosemount 396PVP User manual

Emerson MICROMOTION CNG050 User manual

Emerson

Emerson MICROMOTION CNG050 User manual

Emerson Rosemount 3300HT User manual

Emerson

Emerson Rosemount 3300HT User manual

Emerson Micro Motion 7835 User manual

Emerson

Emerson Micro Motion 7835 User manual

Emerson Micro Motion T Series User manual

Emerson

Emerson Micro Motion T Series User manual

Emerson Micro Motion F Series User manual

Emerson

Emerson Micro Motion F Series User manual

Emerson Rosemount 372 User manual

Emerson

Emerson Rosemount 372 User manual

Emerson Rosemount TupHFET TF396 User manual

Emerson

Emerson Rosemount TupHFET TF396 User manual

Emerson Rosemount 499ATrDO User manual

Emerson

Emerson Rosemount 499ATrDO User manual

Emerson Fisher 249W User manual

Emerson

Emerson Fisher 249W User manual

Emerson Fisher 249 User manual

Emerson

Emerson Fisher 249 User manual

Emerson 203-5751 User manual

Emerson

Emerson 203-5751 User manual

Emerson Liebert Xtreme Density Guide

Emerson

Emerson Liebert Xtreme Density Guide

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Start Guide
00825-0200-2654, Rev BE
June 2016
Rosemount™0065/0185 Sensor Assembly
June 2016
2
Quick Start Guide
NOTICE
This guide provides basic guidelines for Rosemount 0065 and 0185 Sensor models. It does not
provide instructions for configuration, diagnostics, maintenance, service, troubleshooting,
Explosion-proof, Flameproof, or intrinsically safe (I.S.) installations.
If the Rosemount 0065 or 0185 Sensor was ordered assembled to a Rosemount Temperature
Transmitter, see the appropriate Quick Start Guide for information on configuration and
hazardous locations certifications.
WARNING
Explosions could result in death or serious injury.
Installation of this transmitter in an explosive environment must be in accordance with the
appropriate local, national, and international standards, codes, and practices.
Conduit/cable entries
Unless marked, the conduit/cable entries in the transmitter housing use a 1/2–14 NPT thread
form. Entries marked “M20” are M20 ⫻1.5 thread form. On devices with multiple conduit
entries, all entries will have the same thread form. Only use plugs, adapters, glands, or
conduit with a compatible thread form when closing these entries.
Contents
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Sensor Assembly Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Quick Start Guide
3
June 2016
Wiring Diagrams
Figure 1. Rosemount Series 65 RTD Lead Wire Configuration
Note
For 3-wire systems use one white and two red leads. Do not connect the white leads. Insulate or
terminate the unused white lead in a manner that prevents shorting to the ground. For 2-wire
systems, connect both sets of leads.
Flying leads and spring-loaded adapter (termination codes 0, 1, or 3 only)
Single element Dual element
Terminal block (termination code 2 and 4)
Single element Dual element
Red
White
White
Red
Red
Red
Green
Blue
Blue
Black
3
4
1
6
Red
Red
White
White 6
1
3
4
123
4
5
6
4
5
6
1
2
3Red
Red
White
Red
Red
White
June 2016
4
Quick Start Guide
Figure 2. Rosemount Series 185 Thermocouple Lead Wire Configuration
Note
To distinguish the two sensors in Rosemount Dual 185 Sensors (flying lead or spring loaded styles),
the lead wires of one sensor will be longer than the other sensor.
Thermocouple terminal block
Single element Dual element
Table 1. Rosemount Series 185 Thermocouple Characteristics
Type Alloys
(wire color) Sheath material Temp. range (°C)
Limits of error
interchangeability
DIN EN 60584-2
Tolerance
class
JFe (+ black),
CuNi (- white) 1.4541 (321 SST) -40 to 375, 375 to 750 1.5 °C, 0.004 t 1
KNiCr (+ green),
NiAl (- white) 2.4816 (Alloy 600) -40 to 375, 375 to 1000 1.5 °C, 0.004 t 1
NNiCrSi (+ pink),
NiSi (- white) 2.4816 (Alloy 600) -40 to 375, 375 to 1000 1.5 °C, 0.004 t 1
ENi-Cr (+violet),
Cu-NI (-white) 1.4541(321 SST) -40 to 375, 375 to 800 1.5 °C, 0.004t 1
TCu (+brown),
Cu-Ni (-white) 1.4541 (321 SST) -40 to 125, 125 to 350 0.5 °C, 0.004t 1
3
1
1 (+)
3(-)
13
46
4(+)
6(-)
1(+)
3(-)
Quick Start Guide
5
June 2016
Sensor Assembly Dimensions
Sensor assembly without thermowell
Rosemount
248
Rosemount
644
Head or field
mount transmitters
Rosemount IP68 or
IP65 connection
heads
Sensor with flying leads,
terminal block, or spring-loaded
adapter
Extensions
Rosemount 644 with
LCD display meter
Rosemount
3144
40 mm 25 mm
L
16 mm
N★★
N★★
N★★
L
L
★★ N dimension measures from thread
engagement point.
11 mm
11 mm
June 2016
6
Quick Start Guide
Tubular thermowell sensor assembly
Rosemount
248
Rosemount
644
Rosemount IP68 or
IP65, connection
heads
Sensor with flying leads or
terminal block
Threaded and flanged tubular
thermowells
Rosemount 644 with
LCD display meter
40 mm
Head or field
mount transmitters
N
U
U
N
25 mm
NAMUR NAMUR
★★ For straight threading, N
dimension references bottom
of hex. For tapered threading,
N dimension references thread
engagement point (bottom of
thread).
U
N
U
GB GN
★★ ★★
★★
Quick Start Guide
7
June 2016
Barstock thermowell sensor assembly
Sensor with flying leads,
terminal block, or
spring-loaded adapter
Weld-in,
threaded or
flanged
barstock
thermowells
* The Rosemount 644 is available
with or without a LCD display.
Rosemount
3144
Stand-alone
extensions
Rosemount
248
Rosemount
644
Rosemount IP 68
or IP 65
connection heads
Rosemount 644 with
LCD display meter
40 mm
Head or field
mount transmitters
11mm
L
11 mm
16 mm
N★★
11 mm
11 mm
60 mm★★★
U
U
U
60
mm
L
L
★★ N dimension measures from
thread engagement point.
★★★ This dimension is 80 mm for
Class 1500 and Class 2500
flanges.
N★★
N★★
25 mm
T
U
40 mm
U
60
mm
June 2016
8
Quick Start Guide
Product Certifications
European Directive information
A copy of the EC Declaration of Conformity can be found at the end of the Quick
Start Guide. The most recent revision of the EC Declaration of Conformity can be
found at EmersonProcess.com/Rosemount.
Hazardous locations certifications
USA
E5 FM Explosion-proof and Dust-Ignition-proof
Certificate: 0R7A2.AE
Standards: FM Class 3600: 2011; FM Class 3611: 2004; FM Class 3615: 2006; FM Class
3810: 2005; ANSI/NEMA®- 250: 1991
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; T6(–50 °C ≤Ta≤
+155 °C); Type 4X
Canada
E6 CSA Explosion-proof and Dust-Ignition-proof
Certificate: 1063635
Standards: CSA C22.2 No. 0-M91; CSA C22.2 No. 25-1966; CSA C22.2 No. 30-M1986;
CSA C22.2 No. 94-M91; CSA C22.2 No. 142-M1987; CSA C22.2 No.
213-M1987
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; CL I, Div 2, GP A, B, C, D;
(-50 °C ≤Ta≤+85 °C)
Europe
E1 ATEX Flameproof
Certification number: FM12ATEX0065X
Standards: 60079-0:2012; EN60079-1:2007
Markings: II 2 G Ex d IIC T6...T1 Gb, T6(-50 °C ≤Ta≤ +40 °C), T5...T1 (-50 °C ≤ Ta≤
+60 °C), 1180
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature
on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
Quick Start Guide
9
June 2016
I1 ATEX Intrinsic Safety
Certificate: IBExU03ATEX1066X
Standards: EN 60079-0:2012, EN 6079-11:2012, EN 60079-26:2007
Markings: II 1 G Ex ia IIC T6; II 1/2 G Ex ia IIC T6; II 2 G Ex ia IIC T6; 1180
Special Conditions for Safe Use (X):
1. The installation and the operation of the temperature sensors has to be carried out
according to the requirements of the operating instructions.
2. The maximum permissible temperatures of the medium are dependent on the
electric output of the supply in case of failure.
3. With maintenance of the collar-tube distance have to be guaranteed the maximum
permissible ambient temperatures.
4. The maximum ambient temperature for use in Category 1 G is 60 °C.
N1 ATEX Type n
Certificate: BAS00ATEX3145
Standards used: EN 60079-0:2012, EN 60079-15:2010
Markings: II 3 G Ex nA IIC T5 Gc (-40 °C ≤Ta≤+70 °C); 1180
ND ATEX Dust
Certification number: FM12ATEX0065X
Standards Used: EN 60079-0:2012; EN 60079-31: 2009
Markings: II 2 D Ex tb IIIC T130 °C Db (-40 °C ≤Ta≤ +70 °C); 1180
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option “N”.
6. Care shall be taken by the end user to ensure that the external surface temperature
on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
International
E7 IECEx Flameproof
Certificate: IECEx FMG 12.0022X
Standards: IEC60079-0:2011, IEC60079-1:2007-04
Markings: Ex d IIC T6...T1 Gb, T6(-50 °C ≤Ta≤+40 °C), T5…T1(-50 °C ≤Ta≤+60 °C)
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
June 2016
10
Quick Start Guide
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature on
the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
Brazil
E2 INMETRO Flameproof
Certificate: UL-BR 13.0535X
Standards: ABNT NBR IEC 60079-0: 2008 + Corrigendum 1:2011; ABNT NBR IEC
60079-1: 2009 + Corrigendum 1:2011
Markings: Ex d IIC T6...T1 Gb IP66W (-40 °C ≤Ta≤+65 °C)
Special Conditions for Safe Use (X):
1. See product description for ambient temperature limits and process temperature
limits.
2. Guard the LCD display cover against impact energies greater than 4 joules.
3. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
Japan
E4 Japan Flameproof (0065 only)
Certificate: TC17226
Markings: Ex d IIC T6;(-20 °C ≤Ta≤+65 °C); Process Temperature: -20 °C to +85 °C
Special Condition for Safe Use (X):
1. The wiring shall be suitable for a temperature over 80 °C.
EAC – Belarus, Kazakhstan, Russia
EM Technical Regulation Customs Union (EAC) Flameproof
Certificate: RU C-US.GB05.B.00289
Markings: 1Ex d IIC T6…T1 Gb X
Special Condition for Safe Use (X):
1. See certificate for special conditions.
IM Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate: RU C-US.GB05.B.00289
Markings: 0Ex ia IIC T6 Ga X; Ga/Gb Ex ia IIC T6 X; 1Ex ia IIC T6 Gb X
Special Condition for Safe Use (X):
1. See certificate for special conditions.
Combinations
KD Combination of E1, E5, and E6
K1 Combination of E1, I1, N1, and ND
KM Combination of EM and IM