Temperature Capabilities(1) (continued)
With Silicone (VMQ)(3) Diaphragm, Low
Temperature Nitrile (NBR) O-rings and Low
Temperature Bolting: -51 to 82°C / -60 to 180°F
With Gauges: -29 to 82°C / -20 to 180°F
With Automatic Drain: 4 to 79°C / 40 to 175°F
Installation
!
WARNING
Only qualied personnel should install
or service a regulator. Regulators
should be installed, operated and
maintained in accordance with
international and applicable codes
and regulations and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If the regulator vents uid or a leak
develops in the system, it indicates that
service is required. Failure to take the
regulator out of service immediately
may create a hazardous condition.
Personal injury, equipment damage or
leakage due to escaping uid or bursting
of pressure-containing parts may result
if this regulator is overpressured or
is installed where service conditions
could exceed the limits given in
the Specications section or where
conditions exceed any ratings of the
adjacent piping or piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to prevent
service conditions from exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury
and property damage due to escaping
uid. To avoid such injury and damage,
install the regulator in a safe location.
The internal relief valve in the
Types 67DFR and 67DFSR regulators do
not provide full overpressure protection.
The internal relief valve is designed for
minor seat leakage only.
Introduction
This installation guide provides instructions for
installation, startup and adjustment. To receive a copy
of the instruction manual, contact your local Sales
Ofce or view a copy at www.sher.com. For further
information refer to: 67D Series Instruction Manual,
form 5858, D103151X012.
P.E.D. Category
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin: D103053X012.
PRODUCT SIZE CATEGORIES FLUID TYPE
1/2 NPT SEP 1
Specications
Body Size and End Connection Style
1/2 NPT
Maximum Inlet Pressure (Body Rating)(1)
Filtered models: 17.2 bar / 250 psig
Unltered models: 27.6 bar / 400 psig
Maximum Emergency Outlet Pressure(1)
10.3 bar / 150 psig over outlet pressure setting up
to a maximum of 17.2 bar / 250 psig
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive.
Outlet Pressure Ranges(1)
0 to 1.4 bar / 0 to 20 psig
0 to 2.4 bar / 0 to 35 psig
0 to 4.1 bar / 0 to 60 psig
0 to 8.6 bar / 0 to 125 psig
0 to 10.3 bar / 0 to 150 psig
Temperature Capabilities(1)
With Nitrile (NBR)
Standard Bolting: -29 to 82°C / -20 to 180°F
Stainless Steel Bolting: -40 to 82°C / -40 to 180°F
With Fluorocarbon (FKM)
Polyethylene Filter(2) (standard): -18 to 82°C /
0 to 180°F
Polyvinylidene (PVDF), Stainless Steel or Glass
Filter (Optional): -18 to 149°C / 0 to 300°F
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
2. Do not use in high aromatic hydrocarbon service.
3. Silicone (VMQ) is not compatible with hydrocarbon gas.
67D Series
Installation Guide
D103151X014
English – April 2017