ATEX Hazardous Area Approvals
Fisher™4320 Wireless Position Monitor
Hazardous Area Classifications and Special Instructions for “Safe Use” and
Installation in Hazardous Locations
Certain nameplates may carry more than one approval, and each approval may have unique installation/wiring
requirements and/or conditions of “safe use”. These special instructions for “safe use” are in addition to, and may
override, the standard installation procedures. Special instructions are listed by approval.
Note
This information supplements the nameplate markings affixed to the product and the 4320 instruction manual (D103621X012),
available from your Emerson sales office, Local Business Partner, or www.Fisher.com.
Always refer to the nameplate itself to identify the appropriate certification.
WARNING
Failure to follow these conditions of “safe use” could result in personal injury or property damage from fire or explosion,
and area re‐classification.
II 1 G
Intrinsically Safe
Monitor Version
Battery Sourced Power Module w/out Pneumatic Output External Power w/out Pneumatic Output
Ex ia IIC T3/T4/T5 Ga Ex ia IIC T5 Ga
Install per control drawing GE59530 Install per control drawing GE59530
 as shown in figure 1 and 2  as shown in figure 1 and 3
Enclosure: Type 4X, IP66 & IP67 Enclosure: Type 4X, IP66 & IP67
T3(Tamb ≤85_C), T4(Tamb ≤75_C), T5(Tamb ≤40_C) T5(Tamb ≤80_C)
Temperature Range: -40_C to 85_C Temperature Range: -40_C to 80_C
Instruction Manual Supplement
D104306X012
4320 Wireless Position Monitor - ATEX
January 2018
Instruction Manual Supplement
D104306X012
4320 Wireless Position Monitor - ATEX
January 2018
2
Control Version
Battery Sourced Power Module with Pneumatic Output External Power with Pneumatic Output
Ex ia IIC T4/T5/T6 Ga Ex ia IIC T5 Ga
Install per control drawing GE59530 Install per control drawing GE59530
 as shown in figure 1 and 2  as shown in figure 1 and 3
Enclosure: Type 4X, IP66 & IP67 Enclosure: Type 4X, IP66 & IP67
T4(Tamb ≤50_C), T5(Tamb ≤46_C), T6(Tamb ≤31_C) T5(Tamb ≤50_C)
Temperature Range: -20_C to 50_C Temperature Range: -20_C to 50_C
Special Conditions of Use
The apparatus shall not be subjected to mechanical impacts or friction.
The piezo valve can be used with natural gas as control fluid provided that no gas-air mixtures are present in the
pressure system.
HART communication terminals (WP1-WP2) must be only connected to certified intrinsic safety equipment and this
combination must be compatible regarding intrinsic safety rules.
Battery Sourced Power Module:
The apparatus can only be powered with a module type GE57654X012 or GE57655X012
External Power:
The apparatus may be powered externally via external power module GE61615X012
Install per control drawing GE59530 which includes intrinsic safety information.
Figure 1. Installation Drawing Notes; See Figure 2 for Battery Module Assembly & Figure 3 for External Power Option
INSTALLATION MUST BE IN ACCORDANCE WITH THE NATIONAL WIRING PRACTICES OF THE COUNTRY IN USE.
BARRIERS MUST BE CONNECTED PER MANUFACTURE'S INSTALLATION INSTRUCTIONS.
INTRINSICALLY SAFE APPARATUS MAY BE CONNECTED TO ASSOCIATED APPARATUS NOT SPECIFICALLY
EXAMINED IN SUCH COMBINATION. THE CRITERIA FOR INTERCONNECTION IS THAT THE VOLTAGE (Ui) AND
THE CURRENT (Ii) OF THE INTRINSICALLY SAFE APPARATUS MUST BE EQUAL TO OR GREATER THAN THE
VOLTAGE (Uo) AND CURRENT (Io) DEFINED BY THE ASSOCATED APPARATUS. IN ADDITION, THE SUM OF
THE MAXIMUM UNPROTECTED CAPACITANCE (Ci) AND INDUCTANCE (Li) OF EACH INTRINSICALLY SAFE
APPARATUS, AND THE INTERCONNECTING WIRING, MUST BE LESS THAN THE ALLOWABLE CAPACITANCE (Co)
AND INDUCTANCE (Lo) DEFINED BY THE ASSOCIATED APPARATUS. IF THESE CRITERIA ARE MET, THEN THE
COMBINATION MAY BE CONNECTED.
FORMULAS Ui > Uo
Ii > Io
Ci + Ccable < Co
Li + Lcable < Lo
Pi > Po
RESISTANCE BETWEEN BARRIER GROUND AND EARTH GROUND MUST BE LESS THAN ONE OHM.
IF HAND-HELD COMMUNICATOR OR MULTIPLEXER IS USED, IT MUST BE APPROVED WITH ENTITY
PARAMETERS AND INSTALLED PER THE MANUFACTURER'S CONTROL DRAWING.
WARNING
THE APPARATUS ENCLOSURE CONTAINS ALUMINUM AND IS CONSIDERED TO CONSTITUTE
A POTENTIAL RISK OF IGNITION BY IMPACT OR FRICTION. AVOID IMPACT AND FRICTION
DURING INSTALLATION AND USE TO PREVENT RISK OF IGNITION.
GE59530-B, sheet 1
Instruction Manual
D104306X012
4320 Wireless Position Monitor - ATEX
January 2018
3
Figure 2. Installation Drawing for Battery Module Assembly; See Notes in Figure 1
HART COMM TERMINALS
WP1/WP2
BATTERY
MODULE
ASSEMBLY
HAND HELD
HAZARDOUS LOCATION NON-HAZARDOUS LOCATION
INTRINSICALLY SAFE
CLASS I DIV 1 GP ABCD
CLASS I, ZONE 0 GP IIC
4320 POSITION MONITOR
Ui = 6.0 V
Ii = 5 mA
Pi = 30 mW
Ci = 2.5 nF
Li = 0 mH
Uo = 6.0 V
Io = 14 mA
Po = 84 mW
Co = 39 mf
Lo = 150 mH
HART COMM TERMINALS
(BATTERY MODULE - WP1 / WP2)
GE59530-B, sheet 1
MAIN BOARD
ASSEMBLY
Figure 3. Installation Drawing for External Power Option; See Notes in Figure 1
GE59530-B, sheet 2
HART COMM TERMINALS
WP1/WP2
POWER TERMINAL
(J5)
HAND HELD
HAZARDOUS LOCATION NON-HAZARDOUS LOCATION
4320 POSITION
MONITOR POWER
(J5)
I.S APPROVED
BARRIER
POWER TERMINAL
Ui = 28 VDC
Ii = 100 mA
Pi = 1 W
Ci = 78 nF
Li = 2.63 mH
Ui = 6.0 V
Ii = 5 mA
Pi = 30 mW
Ci = 2.5 nF
Li = 0 mH
Uo = 6.0 V
Io = 14 mA
Po = 84 mW
Co = 39 μf
Lo = 150 mH
HART COMM TERMINALS
(WP1 / WP2)
INTRINSICALLY SAFE
CLASS I, DIV 1 GP ABCD
CLASS I, ZONE 0 GP IIC
Instruction Manual Supplement
D104306X012
4320 Wireless Position Monitor - ATEX
January 2018
4
Emerson Automation Solutions
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Cernay, 68700 France
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
E2018 Fisher Controls International LLC. All rights reserved.
Fisher is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions,
Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.

Other manuals for Fisher 4320

7

Other Emerson Measuring Instrument manuals

Emerson Daniel 3410 Series Programming manual

Emerson

Emerson Daniel 3410 Series Programming manual

Emerson Rosemount Clarity II T1056 User manual

Emerson

Emerson Rosemount Clarity II T1056 User manual

Emerson MICRO MOTION HFVM Series Quick guide

Emerson

Emerson MICRO MOTION HFVM Series Quick guide

Emerson OPM 3000 User manual

Emerson

Emerson OPM 3000 User manual

Emerson Daniel Ultrasonic 3410 Series User manual

Emerson

Emerson Daniel Ultrasonic 3410 Series User manual

Emerson Rosemount 5300 Series User manual

Emerson

Emerson Rosemount 5300 Series User manual

Emerson Rosemount 3410 Series Programming manual

Emerson

Emerson Rosemount 3410 Series Programming manual

Emerson Daniel 3415 Programming manual

Emerson

Emerson Daniel 3415 Programming manual

Emerson Rosemount 1054B User manual

Emerson

Emerson Rosemount 1054B User manual

Emerson Rosemount Xi User manual

Emerson

Emerson Rosemount Xi User manual

Emerson Rosemount 8800D Series User manual

Emerson

Emerson Rosemount 8800D Series User manual

Emerson FB1100 Parts list manual

Emerson

Emerson FB1100 Parts list manual

Emerson Rosemount Oxymitter DR User manual

Emerson

Emerson Rosemount Oxymitter DR User manual

Emerson Rosemount Clarity II T56 User manual

Emerson

Emerson Rosemount Clarity II T56 User manual

Emerson RLDS Operating instructions

Emerson

Emerson RLDS Operating instructions

Emerson RXi HMI User manual

Emerson

Emerson RXi HMI User manual

Emerson 6888i User manual

Emerson

Emerson 6888i User manual

Emerson Rosemount Analytical X-STREAM Enhanced... How to use

Emerson

Emerson Rosemount Analytical X-STREAM Enhanced... How to use

Emerson TopWorx 4310 User manual

Emerson

Emerson TopWorx 4310 User manual

Emerson Micro Motion TA Series User manual

Emerson

Emerson Micro Motion TA Series User manual

Emerson Rosemount CT5100 User manual

Emerson

Emerson Rosemount CT5100 User manual

Emerson Rosemount 3051SF Series User manual

Emerson

Emerson Rosemount 3051SF Series User manual

Emerson Rosemount 585 Annubar User manual

Emerson

Emerson Rosemount 585 Annubar User manual

Emerson Rosemount Analytical 400A User manual

Emerson

Emerson Rosemount Analytical 400A User manual

Popular Measuring Instrument manuals by other brands

NOYAFA NF-820 instruction manual

NOYAFA

NOYAFA NF-820 instruction manual

LINSHANG LS110 user manual

LINSHANG

LINSHANG LS110 user manual

EUTECH INSTRUMENTS CyberScan IR TB100 instruction manual

EUTECH INSTRUMENTS

EUTECH INSTRUMENTS CyberScan IR TB100 instruction manual

koban KTO AT-8 manual

koban

koban KTO AT-8 manual

Greenlee GOPM Micro-01 user guide

Greenlee

Greenlee GOPM Micro-01 user guide

Omega FLR 1000 user manual

Omega

Omega FLR 1000 user manual

Water I.D. Pool Lab 1.0 user manual

Water I.D.

Water I.D. Pool Lab 1.0 user manual

WIKA CTD9100-1100 operating instructions

WIKA

WIKA CTD9100-1100 operating instructions

Milltronics IQ Radar 160 instruction manual

Milltronics

Milltronics IQ Radar 160 instruction manual

wheeler 710904 instructions

wheeler

wheeler 710904 instructions

Panduit OPTICAM 2 quick start guide

Panduit

Panduit OPTICAM 2 quick start guide

ECD MOLE EV6 Quick reference guide

ECD

ECD MOLE EV6 Quick reference guide

Extech Instruments 461920 manual

Extech Instruments

Extech Instruments 461920 manual

Applent Instruments AT2818 user guide

Applent Instruments

Applent Instruments AT2818 user guide

Trimax Vulcan instructions

Trimax

Trimax Vulcan instructions

Joinwit JW8001 user manual

Joinwit

Joinwit JW8001 user manual

brennenstuhl FL Duo operating instructions

brennenstuhl

brennenstuhl FL Duo operating instructions

CLA-VAL X144D e-FlowMeter Quick Start Installation & Removal Instructions

CLA-VAL

CLA-VAL X144D e-FlowMeter Quick Start Installation & Removal Instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.