manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Security Sensor
  8. •
  9. Emerson Rosemount 975 User manual

Emerson Rosemount 975 User manual

Quick Start Guide
00825-0700-4975, Rev AA
June 2021
Rosemount™ 975
Air Shield
Legal notice
The device described in this document is the property of Emerson.
No part of the hardware, software, or documentation may be reproduced, transmitted, transcribed,
stored in a retrieval system, or translated into any language or computer language, in any form or by
any means, without prior written permission from Emerson.
While great efforts have been made to ensure the accuracy and clarity of this document, Emerson
assumes no liability resulting from any omissions in this document or from misuse of the information
obtained herein. The information in this document has been carefully checked and is believed to be
entirely reliable with all of the necessary information included. Emerson reserves the right to make
changes to any products described herein to improve reliability, function, or design and reserves the
right to revise this document and make changes from time to time in content hereof with no
obligation to notify any persons of revisions or changes. Emerson does not assume any liability arising
out of the application or any use of any product or circuit described herein; neither does it convey
license under its patent rights or the rights of others.
WARNING
All individuals who have or will have responsibility for using, maintaining, or servicing this product
must read this document carefully.
WARNING
Physical access
Unauthorized personnel may potentially cause significant damage to and/or misconfiguration of end
users’ equipment. This could be intentional or unintentional and needs to be protected against.
Physical security is an important part of any security program and fundamental to protecting your
system. Restrict physical access by unauthorized personnel to protect end users’ assets. This is true for
all systems used within the facility.
Warranty
1. Limited Warranty . Subject to the limitations contained in Section 2 (Limitation of Remedy
and Liability) herein, Seller warrants that (a) the licensed firmware embodied in the Goods
will execute the programming instructions provided by Seller; (b) that the Goods
manufactured by Seller will be free from defects in materials or workmanship under normal
use and care; and (c) Services will be performed by trained personnel using proper equipment
and instrumentation for the particular Service provided. The foregoing warranties will apply
until the expiration of the applicable warranty period. Sensors and detectors are warranted
against defective parts and workmanship for 24 months from the date of purchase and other
electronic assemblies for 36 months from the date of purchase. Products purchased by Seller
from a third party for resale to Buyer (Resale Products) shall carry only the warranty extended
by the original manufacturer. Buyer agrees that Seller has no liability for Resale Products
beyond making a reasonable commercial effort to arrange for procurement and shipping of
the Resale Products. If Buyer discovers any warranty defects and notifies Seller thereof in
writing during the applicable warranty period, Seller shall, at its option, (i) correct any errors
that are found by Seller in the firmware or Services; (ii) repair or replace FOB point of
manufacture that portion of the Goods found by Seller to be defective; or (iii) refund the
purchase price of the defective portion of the Goods/Services. All replacements or repairs
necessitated by inadequate maintenance; normal wear and usage; unsuitable power sources
or environmental conditions; accident; misuse; improper installation; modification; repair;
use of unauthorized replacement parts; storage or handling; or any other cause not the fault
of Seller, are not covered by this limited warranty and shall be replaced or repaired at Buyer's
sole expense, and Seller shall not be obligated to pay any costs or charges incurred by Buyer
or any other party except as may be agreed upon in writing in advance by Seller. All costs of
dismantling, reinstallation, freight, and the time and expenses of Seller's personnel and
Quick Start Guide June 2021
2 Emerson.com/Rosemount
representatives for site travel and diagnosis under this limited warranty clause shall be borne
by Buyer unless accepted in writing by Seller. Goods repaired and parts replaced by Seller
during the warranty period shall be in warranty for the remainder of the original warranty
period or 90 days, whichever is longer. This limited warranty is the only warranty made by
Seller and can be amended only in a writing signed by an authorized representative of Seller.
The limited warranty herein ceases to be effective if Buyer fails to operate and use the Goods
sold hereunder in a safe and reasonable manner and in accordance with any written
instructions from the manufacturers. THE WARRANTIES AND REMEDIES SET FORTH ABOVE
ARE EXCLUSIVE. THERE ARE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND,
EXPRESSED OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, OR
ANY OTHER MATTER WITH RESPECT TO ANY OF THE GOODS OR SERVICES.
2. Limitation of Remedy and Liability SELLER SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY
DELAY IN PERFORMANCE. THE REMEDIES OF BUYER SET FORTH IN THE AGREEMENT ARE
EXCLUSIVE. IN NO EVENT, REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION
(WHETHER BASED IN CONTRACT INFRINGEMENT, NEGLIGENCE, STRICT LIABILITY, OTHER
TORT, OR OTHERWISE), SHALL SELLER'S LIABILITY TO BUYER AND/OR BUYER'S CUSTOMERS
EXCEED THE PRICE TO BUYER OF THE SPECIFIC GOODS MANUFACTURED OR SERVICES
PROVIDED BY SELLER GIVING RISE TO THE CLAIM OR CAUSE OF ACTION. BUYER AGREES
THAT IN NO EVENT SHALL SELLER'S LIABILITY TO BUYER AND/OR BUYER'S CUSTOMERS
EXTEND TO INCLUDE INCIDENTAL, CONSEQUENTIAL, OR PUNITIVE DAMAGES. THE TERM
"CONSEQUENTIAL DAMAGES" SHALL INCLUDE, BUT NOT BE LIMITED TO, LOSS OF
ANTICIPATED PROFITS, REVENUE, OR USE AND COSTS INCURRED INCLUDING WITHOUT
LIMITATION FOR CAPITAL, FUEL AND POWER, AND CLAIMS OF BUYER'S CUSTOMERS.
Contents
Description.................................................................................................................................. 5
Installation................................................................................................................................... 6
Technical specifications..............................................................................................................11
June 2021 Quick Start Guide
Quick Start Guide 3
Quick Start Guide June 2021
4 Emerson.com/Rosemount
1 Description
This document provides installation instructions for the Air Shield (PN
00975-9000-0005). Use the Air Shield with the Rosemount 975 Flame
Detectors.
Optical flame detectors are often used in highly polluted or dirty areas,
where maintenance personnel must access the detector frequently to clean
its optical window. The special air shield allows operators to install detectors
in tough environmental conditions, where they may be exposed to oil
vapors, sand, dust, and other particulate matter.
June 2021 Quick Start Guide
Quick Start Guide 5
2 Installation
2.1 Prepare surfaces
Procedure
1. Verify that all connection surfaces are clean.
2. Open the lock screw.
The screw is a captive screw.
Figure 2-1: Surface Preparation
A. Connection surfaces
B. Lock screw
Quick Start Guide June 2021
6 Emerson.com/Rosemount
2.2 Assemble Air Shield
Procedure
1. Assemble the Air Shield on the detector.
Figure 2-2: Rear View
A. Air Shield rear view
B. Detector
June 2021 Quick Start Guide
Quick Start Guide 7
Figure 2-3: Front View
Quick Start Guide June 2021
8 Emerson.com/Rosemount
2. Lock the screw.
Figure 2-4: Locking the Screw
June 2021 Quick Start Guide
Quick Start Guide 9
3. Attach the air pressure hose to the quick-fit air connection.
Figure 2-5: Quick-Fit Air Connection
A. Quick-fit air connection
Quick Start Guide June 2021
10 Emerson.com/Rosemount
3 Technical specifications
WARNING
The temperature of the air supply to the air shield should never exceed 140
°F (60 °C).
Air pressure source Clean, dry, and oil-free air
Inlet pressure 30-40 psig (2-3 bar)
102 psig (7 bar)
Fitting: 7/16 in. – 20UNF-2A
Air volume: 1.5 cubic feet per minute (CFM)
Tube outside diameter (OD) ¼-in. (6 mm)
Operation temperature -67 to 185 °F (-55 to 85 °C)
Note
The Air Shield will limit the flame detector's cone of view to 70 ° (35 ° each
side, vertically and horizontally).
June 2021 Quick Start Guide
Quick Start Guide 11
*00825-0700-4975*
Quick Start Guide
00825-0700-4975, Rev. AA
June 2021
For more information: www.emerson.com
©2021 Emerson. All rights reserved.
Emerson Terms and Conditions of Sale are
available upon request. The Emerson logo
is a trademark and service mark of
Emerson Electric Co. Rosemount is a mark
of one of the Emerson family of
companies. All other marks are the
property of their respective owners.

Other manuals for Rosemount 975

3

Other Emerson Security Sensor manuals

Emerson Rosemount 226 User manual

Emerson

Emerson Rosemount 226 User manual

Emerson Rosemount 975MR User manual

Emerson

Emerson Rosemount 975MR User manual

Emerson Rosemount 2160 User manual

Emerson

Emerson Rosemount 2160 User manual

Emerson GW-810-3760 User manual

Emerson

Emerson GW-810-3760 User manual

Emerson Net Safety Millennium User manual

Emerson

Emerson Net Safety Millennium User manual

Emerson Dixell GDS41M Wiring diagram

Emerson

Emerson Dixell GDS41M Wiring diagram

Emerson MRLDS-250 User manual

Emerson

Emerson MRLDS-250 User manual

Emerson REED Series User manual

Emerson

Emerson REED Series User manual

Emerson Rosemount 2160 User manual

Emerson

Emerson Rosemount 2160 User manual

Emerson ROSEMOUNT 242 User manual

Emerson

Emerson ROSEMOUNT 242 User manual

Emerson GDU-Incus User manual

Emerson

Emerson GDU-Incus User manual

Emerson Rosemount 2140 User manual

Emerson

Emerson Rosemount 2140 User manual

Emerson F145RF-1600 User manual

Emerson

Emerson F145RF-1600 User manual

Emerson Dixell GDS41 Wiring diagram

Emerson

Emerson Dixell GDS41 Wiring diagram

Emerson CT2211 User manual

Emerson

Emerson CT2211 User manual

Emerson Rosemount 2160 User manual

Emerson

Emerson Rosemount 2160 User manual

Emerson Rosemount 389 User manual

Emerson

Emerson Rosemount 389 User manual

Emerson Rosemount 975HR User manual

Emerson

Emerson Rosemount 975HR User manual

Emerson Rosemount 396P User manual

Emerson

Emerson Rosemount 396P User manual

Emerson White-Rodgers 902 User manual

Emerson

Emerson White-Rodgers 902 User manual

Emerson Machinery Health AMS EZ 1000 User manual

Emerson

Emerson Machinery Health AMS EZ 1000 User manual

Emerson Rosemount 3900 User manual

Emerson

Emerson Rosemount 3900 User manual

Emerson Mobrey Manual

Emerson

Emerson Mobrey Manual

Emerson CHD200G User manual

Emerson

Emerson CHD200G User manual

Popular Security Sensor manuals by other brands

Indexa FD01 Operating and safety instructions

Indexa

Indexa FD01 Operating and safety instructions

brennenstuhl MD operating instructions

brennenstuhl

brennenstuhl MD operating instructions

SMC Networks PSE56 Series Operation manual

SMC Networks

SMC Networks PSE56 Series Operation manual

Berker 7566 27 Series instructions

Berker

Berker 7566 27 Series instructions

ESYLUX COMPACT PD-C 360/8 BMS DALI-2 operating instructions

ESYLUX

ESYLUX COMPACT PD-C 360/8 BMS DALI-2 operating instructions

LEGRAND 0 490 8 installation instructions

LEGRAND

LEGRAND 0 490 8 installation instructions

Conrad 75 19 01 operating instructions

Conrad

Conrad 75 19 01 operating instructions

Siemens 5TC1700 operating instructions

Siemens

Siemens 5TC1700 operating instructions

Schwaiger Secure4You HGA300 532 instructions

Schwaiger

Schwaiger Secure4You HGA300 532 instructions

DSC The NEW FORCE 2 F2-210 installation instructions

DSC

DSC The NEW FORCE 2 F2-210 installation instructions

Detectors Incorporated D381 instruction manual

Detectors Incorporated

Detectors Incorporated D381 instruction manual

GE Security EST3 Installation and service manual

GE Security

GE Security EST3 Installation and service manual

MTI Industries Safe-T-Alert SA-10XL user manual

MTI Industries

MTI Industries Safe-T-Alert SA-10XL user manual

Be Cool BC23KMM828 manual

Be Cool

Be Cool BC23KMM828 manual

eufy Security Smart Buoy user manual

eufy Security

eufy Security Smart Buoy user manual

Radiodetection RD5100 H2O+ user guide

Radiodetection

Radiodetection RD5100 H2O+ user guide

Memco Panachrome+ installation guide

Memco

Memco Panachrome+ installation guide

BEA LZR-FLATSCAN SW quick guide

BEA

BEA LZR-FLATSCAN SW quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.