Emfit QS IP-9360 User manual

Unsuccessful connection
Device will make low tone sounds. Red and
green lights flash alternately again. This means
device has returned to state it was in step 6
(Access Point mode). Please try again starting
from step 6 and make sure you typed your own
Wi-Fi network password correctly.*
Red and green lights are flashing alternately.
*Still cannot connect? Please see chapter
Troubleshooting in “Installation & operating
instructions” (https://qs.emfit.com/docs).
Connect the power cord to Emfit QS.
Upon powering the device will scan all
available Wi-Fi networks. Note this especially
using a mobile device as hotspot Wi-Fi .
2.3.
5. 4.6.
7.
This guide
1.
Sensor
EMFIT QS
with Wi-Fi transceiver
Data signal
Keep electronic unit
minimum of 30 cm
distance away from body. 8A password is requested.
Emfit XXX is requesting
WPA2-password
Password:
Show the password
Remember this network
Cancel OK
A) New device setup
Page 1
Select a suitable adapter.
12Connect the correct adapter.
Ensure that it locks in its place.
CLICK!
3Connect the power supply to electrical outlet
(110 - 230V AC).
Power cord
4
Power cord Sensor cord
Power cord
5Green and red lights start to flash alternately
and device makes beep sounds.
Green
Red
Green
Red
Green Green GreenRed Red Red
…
Sensor cord
7
Ignore possible “No internet connection”.
Select and connect to the network:
Emfit_xxxxxx (where xxxxxx is the serial num-
ber of your device).
Windows
Networks
Connections
Wi-Fi
ConnectedNetwork
Emt_1234567
Some-Guest-2.4GHz
2WIRE123
Mac OSX
Turn Wi-Fi O
Emt_1234567
AppleWiFi
Testwork
Join Other Network…
Create Network…
Open Network Preferences…
Wi-Fi: On
With your computing device scan for wireless
networks.
6
Computing device
SCANNING
9
Emt Ltd, Finland | Product: Emt QS | Model: IP-9360
Contains FCC ID: W70MRF24WG0MAMB
Contains transmitter module IC:
7693A-24WG0MAMB
Designed and manufactured in Finland.
SN: XXXXXX
PIN: XXXXX
PW: XXX-XXXX-XXX
http://192.168.1.3
Find the password at the back of the Emfit QS
device (PW: XXX-XXXX-XXX).
Note! The password must be filled in with the
hyphens.
12 Press enter and EMFIT QS will now try to con-
nect to your Wi-Fi network. Connecting can
take up to few minutes. You hear short “beep”
sounds and see the red led flashing.
Red light starts flashing.
11 Select your own Wi-Fi network from the list,
type its password and click enter.
If you do not see your wireless network,
please notice what is said in Step 5.
If you still cannot find your Wi-Fi network,
please see chapter Troubleshooting in
“Installation & operating instructions”
(https://qs.emfit.com/docs).
http://192.168.1.3
Emt
“Your network”
Detected Wireless Networks
Other Network…
13 Successful connection
Device will make high tone sounds. This means
that the password you typed is correct. To ver-
ify succesful connection, ensure the sensor is
not sensing any vibration and is preferably un-
der the mattress; see section C 22–25.
In about 1-3 minutes either green light will start
flashing, or red light alone will keep flashing. If the
later, please contact Emfit support:
Email: qs@emfit.com
Phone: USA (512) 266-6950, EU +358 20 778 0870
14
1. Sensor with attached signal conditioner and Wi-Fi module
2. Power supply
3. Plug adapter for European countries
4. Plug adapter for United Kingdom
5. Plug adapter for USA and Canada
6. Plug adapter for Australia
7. This guide
Package contents
This Quick Guide contains information extracted from the instructions
for use. Please read the “Installation & operating instructions” for the
full instructions for use, including information on safety from:
https://qs.emfit.com/docs
Overview
10 Open your computing device’s browser
(Mozilla, Safari, Chrome, Internet Explorer etc.).
Type in address/url bar:
http://192.168.1.3 and press enter.
If you cannot access above IP-address,
please see chapter Troubleshooting in
“Installation & operating instructions”
(https://qs.emfit.com/docs).
http://192.168.1.3
The 5 GHz Wi-Fi is not supported.
Wi-Fi channels 12 , 13 and 14 are not supported.
This concerns European customers especially.
2.4 GHz Wi-Fi is supported.
Wi-Fi channels 1 - 11 are supported.
or
To operate, EMFIT QS needs Internet
connection. It can be either:
Wi-Fi requirements
Your Wi-Fi network password
Home Wi-Fi
with Internet access
A
Mobile device as
Wi-Fi hotspot
Your hotspot Wi-Fi network password
B
A computing device*
(computer or tablet or smartphone
with browser)
To set up the Wi-Fi you need
(once):
Note! Make sure address starts with http
and not https!
If only the red led flashes you need to restore the de-
vice into AP mode. Please see chapter Restoring Emfit
QS device to Access Point (AP) mode in “Installation &
operating instructions” (https://qs.emfit.com/docs).
* NOTE! Also for you need an additional
computing device for setup
If you do not know whether your home Wi-Fi is compatible, please see chapter Troubleshooting in
“Installation & operating instructions” (https://qs.emfit.com/docs).
Safety instructions
If the device gets wet or starts overheating stop using
immediately and disconnect power
supply from mains power.
Equipment is not suitable for use in the presence of a
flammable anaesthetic mixture with air
or with oxygen or nitrous oxide.
Only use the power supply (as specified in chapter
Technical specifications) supplied with the product.
This product is designed for indoor use only.
This product IS NOT intended to be used for direct
diagnosis or monitoring of disease or
other conditions, or physiological processes.
Do not use this device for any purpose other than
that specified by the manufacturer.
Do not try to repair the device yourself.
If the instructions are not adhered to, the situation may lead to a death or serious personal injury (in these instructions for use).
ATTENTION - consult accompanying documents (i.e. these instructions for use)
Means that the section contains important information for the user (in these instructions for use).
The EMFIT QS hardware (Product) and web application (Service) together is a general
wellness product intended to be used for tracking the impact of free-time activities on
recovery, fatigue and sleep quality on a healthy subject. It is not a medical device and is not
intended to be used for diagnosis or monitoring of disease or other conditions, or investiga-
tion of a physiological process.
The product consists of electronic unit with attached bed sensor and a separate power
supply.
Intended use
Environmental conditions
Storage and transportation
• Temperature: -30°C - +50°C
• Relative humidity: ≤80%
Use
• Temperature: +10°C - +40°C
• Relative humidity: ≤75%
• Altitude: <3000 m
Cleaning
CAUTION Do not spray, pour or spill liquid onto the power supply, device, cables, or sensor.
The Emfit device may be surface-cleaned using a so cloth dampened with either a commercial, nonabrasive cleaner or a
solution of 70% alcohol in water. Lightly wipe the surfaces of the device, power supply, cables and sensor.
EMFIT QS New device setup guide A2_v.3.0_28.5.2019.indd 1 5.6.2019 10.51

Setup, registration
& installation guide
for model IP-9360 (Wi-Fi)
v3.0
28.5.2019
HEART CONTRACTIONS, BREATHING
AND BODY MOVEMENT ANALYTICS IN SLEEP
You will be directed to the Emfit QS web
application.
21
B) Register your device Aer successful Wi-Fi connection, it is time to register your device.
… or you can place it
beneath the mattress.
You can place the EMFIT QS
beneath the mattress topper…
Go to https://qs.emfit.com
and click “Register your device”.
15 Locate your serial and PIN
numbers on the back of the
device.
PASSWORD TO YOUR DEVICE (AP ACCESS POINT)
YOUR SERIAL NUMBER
YOUR PIN NUMBER
16
YOUR SERIAL NUMBER
YOUR PIN NUMBER
Insert serial number and PIN number of your
device.
Click “next”.
17 Fill/choose the details.
Click “register”.
18
This will open.
Click “close”.
19 Go and check your email for our verification
email*. Open it and click the link in it.
(If you do not receive the confirmation message
within a few minutes of signing up, please check
your Spam folder just in case the confirmation
email got delivered there instead of your inbox.)
* If you do not receive the email at all, you can go
directly to https://qs.emfit.com and log in (click-
ing the verification link is not necessary).
Your device will show up at the interface shortly
aer you’ve gone to bed. First sleep report is
available next morning.
20
Page 2
www.emfit.com
Emfit, Corp.
P.O. Box 342394
Austin, TX 78734
United States
Phone: (512) 266-6950
qs@emfit.com
USA
Emfit Ltd
Konttisentie 8 B
40800 Vaajakoski
FINLAND
Phone: +358 20 778 0870
qs@emfit.com
EUROPEAN UNION
C) Install the sensor in your bed
22 Place the bed sensor
beneath the mattress or
mattress topper across
the bed under your
chest area.
Placing the EMFIT QS in double bed
If you sleep with a partner in a double bed, place the sensor on to your side
of the bed as far as possible from your partner. Make sure the sensor is still
under your chest area.
You can bend the sensor over the corner of your mattress. It will help to
prevent sensing your partner’s heart rate, especially when you leave the
bed earlier than he/she.
NOTE! Place the Wi-Fi module
on the floor. It should be at mini-
mum 30 cm distance away from
your body.
The device works most reliably when the
sensor is located substantially below your heart.
23 25
24
GENERAL NOTE: THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMEN-
TATION (THE “PRODUCT”) IS SUBJECT EMFIT LTD GRANTS A NON-EXCLUSIVE RIGHT TO USE
THE PRODUCT. THE RECIPIENT SHALL NOT TRANSFER, COPY, MODIFY, TRANSLATE, REVERSE
ENGINEER, CREATE DERIVATIVE WORKS; DISASSEMBLE OR DECOMPILE THE PRODUCT OR OTH-
ERWISE USE THE PRODUCT EXCEPT AS SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS
DOCUMENT ARE PROVIDED ON AN “AS IS” BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR
INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, EMFIT LTD DIS-
CLAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED
PERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PROVIDED
TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE SHALL BE
GOVERNED AND CONSTRUED ACCORDING TO FINNISH LAW.
COPYRIGHT: TRANSMITTAL, REPRODUCTION, DISSEMINATION AND/OR EDITING OF THIS DOCUMENT AS WELL AS UTILIZATION OF ITS CON-
TENTS AND COMMUNICATION THEREOF TO OTHERS WITHOUT EXPRESS AUTHORIZATION ARE PROHIBITED. OFFENDERS WILL BE HELD LI-
ABLE FOR PAYMENT OF DAMAGES. ALL RIGHTS CREATED BY PATENT GRANT OR REGISTRATION OF A UTILITY MODEL OR DESIGN PATENT
ARE RESERVED. EMFI, EMFIT, EMFIT QS, QS LOGO AND EMFIT LOGO ARE REGISTERED TRADEMARKS OR TRADEMARKS OF EMFIT LTD. © EMFIT
LTD 2004-2018. ALL RIGHTS RESERVED. PATENTED, PATENTS PENDING. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NO-
TICE. MOZILLA, SAFARI, CHROME, INTERNET EXPLORE, WINDOWS 10 ARE REGISTERED TRADEMARKS OF MOZILLA FOUNDATION, APPLE INC.,
GOOGLE INC. AND MICROSOFT CORP. WITH WHOM EMFIT IS NOT AFFILIATED.
Please read the “Installation & operating instructions” for the full
instructions for use, including information on safety from:
https://qs.emfit.com/docs
Release date Revision
v1.0
v.1.1
v.1.2
v.1.3
v.1.4
v1.5
v1.6
v1.7
v1.8
v1.9
v2.0
v2.1
v2.2
v3.0
23.2.2017
4.5.2017
1.6.2017
10.8.2017
11.9.2017
4.10.2017
25.10.2017
22.1.2018
9.2.2018
20.4.2018
10.9.2018
26.2.2019
14.5.2019
28.5.2019
The warranty of Emfit products is valid for 24 months from the purchase date. The warranty covers
structural, material and manufacturing defects. The warranty does not cover normal wear or de-
fects caused by it. Emfit can demand a purchase invoice, receipt or other verification for deliveries
to warranty services.
The warranty does not cover damages or problems caused by use of other additional devices, such
as routers. The warranty also does not cover self-inflicted problems, such as careless use.
The warranty does not cover damages caused by external matters (such as thunder or water leak-
age). The warranty does not cover any indirect ramification damages such as personal damages,
a decrease of production, a decrease in revenue, etc. Emfit Ltd is not liable for such consequences
in any way.
Emfit Ltd has a right to exchange a defected product to another equivalent product. The exchanged
product becomes the ownership of Emfit Ltd. Exchanging a product does not elongate the original
warranty.
Actions in warranty repairs
The customer has to contact the vendor or Emfit Ltd and agree upon sending the device to warranty
repair. Tell the serial number (found at the back of the electronics device), purchase date, defect
description and your own contact information. Aer this, you will receive instructions for sending
the device.
When the product is shipped, it has to be carefully packed and the power source has to be shipped
with the device. Personal contact information, including phone number and defect description,
must be included as well.
Actions when contacting technical support
Free of charge technical service is available from 9 am to 4 pm on business days (Finnish time,
GMT+2) at +358 20 778 0870. Questions for technical support can also be sent to qs@emfit.com.
Be prepared to give technical support the serial number of your device.
Emfit warranty, its terms
of condition and techni-
cal support
EUROPEAN UNION:
Declaration of Conformity
We, the manufacturer Emfit Ltd., hereby declare that Emfit
QS model IP-9360 complies with the essential requirements
of EMC directive 2004/108/EC , R&TTE directive 1999/5/EC
and CE mark directive 93/68/EEC and carries the CE mark-
ing accordingly. Manufacturer’s undersigned declaration of
conformity (EU) is available by request from the manufac-
turer.
USA:
FCC notice to users
Contains FCC ID: W7OMRF24WG0MAMB
This device complies with Part 15 of the FCC Rules. Opera-
tion is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must
accept any interference received, including interference that
may cause undesired operation.
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reason-
able protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate
radio frequency energy, and if not installed and used in ac-
cordance with the instructions, may cause harmful interfer-
ence to radio com-munications. However, there is no guaran-
tee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and re-
ceiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer
To satisfy FCC RF Exposure requirements for mobile and
base station transmission devices, a separation distance of
20 cm or more should be maintained between the antenna
of this device and persons during operation. To ensure com-
pliance, operation at closer than this distance is not recom-
mended. The antenna(s) used for this transmitter must not
be co-located or operating in conjunction with any other
antenna or transmitter.
CANADA:
Contains transmitter module IC:
7693A-24WG0MAMB
This device complies with Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including inter-
ference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Can-
ada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utili-
sateur de l’appareil doit accepter tout brouillage radioélectri-
que subi, même si le brouillage est susceptible d’en compro-
mettre le fonctionnement.
DISPOSAL OF THE DEVICE AFTER USE
In EU:
In conformity with the Waste Electrical and Electronic Equip-
ment Directive (WEEE Directive 2002/96/EC), the device
must be collected separately and returned to an authorized
collection facility. The owner must take the device to the
waste collection point specified by local authorities. For
more information on how to dispose of the device, please
contact the relevant authorities.
USA & Canada:
Please do not dispose Emfit electrical devices or accessories
with your household waste. These items should be disposed
of in accordance with the national collection and recycling
schemes operated by your local or regional authority. Alter-
natively, you may return unwanted Emfit devices and elec-
trical accessories to any Emfit approved distributor or dealer
in your region.
RESTRICTIONS OF THIS RADIO EQUIPMENT
NO
Norway:
Use of this radio equipment is not allowed in the geograph-
ical area within a radius of 20 km from the centre of Ny-
Ålesund, Svalbard, Norway.
ELECTROMAGNETIC COMPATIBILITY (EMC) AND RADIO SPECTRUM MATTERS (ERM)
Regulatory Statements
EMFIT QS New device setup guide A2_v.3.0_28.5.2019.indd 2 5.6.2019 10.51
Other Emfit Medical Equipment manuals
Popular Medical Equipment manuals by other brands

RaySafe
RaySafe i2 Installation and Maintenance

Storz
Storz XENON 300 Service manual

Physiolab
Physiolab S1 user manual

Freedom Innovations
Freedom Innovations PLIE 3 Programming reference guide

Albrecht
Albrecht HALLUXSAN User instructions

AIROS Medical
AIROS Medical AIROS 6 Operating instructions and user guide