Dear Customer,
congratulations on the purchase of the EMP-Centauri product. Before its installation and putting into
operation, read carefully the entire operation manual. Keep the purchase and rework if any) records for
future need.
1) Field of Application, Warranty
The product is designed for the distribution of satellite & terrestrial including cable) TV and radio signals. Its
main purpose is to allow connecting of multiple user to the common antenna SMATV).
The manufacturer provides for E.LITE CLASS products extended 4 four) years warranty from the date of
purchase, see details in EMP-Centauri’s General trade conditions, published at manufacturer’s website
www.emp-centauri.cz.
It is prohibited to dismantle the product and make any interventions in it. Repairs or any interventions in the
product may be performed only by EMP-Centauri company, or other companies authorized by EMP-
Centauri.
2) Technical Specifications
Products are cascadable multiswitches for distribution of terrestrial and satellite signals from 4 satellite
positions 16 polarities) to up to 30 users, depending on model. All trunk lines are passive, also internal
network for terrestrial band is passive.
The multiswitch is DC supplied from connected satellite receivers, DC2.1 socket for external power is
connected to all satellite trunk lines. DC pass is provided through the TERR line.
Specification MS17/17+
6E P-4
MS17/17+
10E P-4
MS17/17+
16E P-12
MS17/17+
20E P-12
MS17/17+
26E P-17
MS17/17+
30E P-17
Number of Trunk Lines 17 16 x SAT, 1 x TERR)
Number of User Outputs 6 10 16 20 26 30
Frequency Range SAT 950–2150 MHz, TERR 40–862 MHz
Insertion Loss – User Outputs* SAT 5 dB, TERR 22 dB SAT 5 dB, TERR 28 dB SAT 5 dB, TERR 35 dB
Insertion Loss – Trunk Lines* SAT 3 dB, TERR 4 dB SAT 4 dB, TERR 8 dB SAT 5 dB, TERR 6 dB
Isolation – User Outputs min) 20 dB
Isolation – Trunk Lines min) 25 dB
Maximum Input level** SAT 105 dBuV, TERR 105 dBuV
Max. Level at User Outputs** SAT 100 dBuV
TERR 83 dBuV
SAT 100 dBuV
TERR 77 dBuV
SAT 100 dBuV
TERR 70 dBuV
1 of 4
Specification MS17/17+
6E P-4
MS17/17+
10E P-4
MS17/17+
16E P-12
MS17/17+
20E P-12
MS17/17+
26E P-17
MS17/17+
30E P-17
Current drawn 100 mA per user output)
Dimensions w,d,h) 18.6 x 14.6 x 5.1 cm 18.6 x 24.5 x 5.1 cm 18.6 x 33.2 x 5.1 cm
Temperature Range −25 – +60 °C
Notes: * average value ** according to EN 50083-3/35dB IMA3 SAT), EN 50083-3/60dB IMA3 TERR)
3) Product Takeover
Make sure that the product is not damaged. In the case of damage please contact your dealer.
4) Product Storing and Installation
We recommend the device to be installed and serviced by the qualified technician.
The product must not be stored and installed:
•in the place with excessive humidity
•in the place with dropping or splashing water,
•in the place with excessive dust pollution, mechanical vibrations or impacts
•in the place out of temperature limits specified in the section 2) Technical Specifications
•close to heat sources radiators or air ventilators, direct sunshine etc.)
•in the reach of children
Use the apparatus only in moderate climates not in tropical climate).
Fix the product firmly on a wall or another hard and inflammable surface with screws and dowels. The
product shall be in no case held only by the connected cables.
Further instructions:
•ensure the free space at least 10 cm around the product for the sufficient air circulation
•do not cover the product with curtains etc.)
•do not place any containers with liquids vases, glasses etc.) or naked flame sources lighted
candle etc.) on the product or near the product
5) Product onnection
Connect the product in accordance with this manual and valid regulation in you country. Use high quality
75 Ω coaxial cable designed for satellite reception. The coaxial cables shall not be broken, the minimum
bending radius should be 5 cm. Mount the F connectors screw, crimp or compress type) on the ends of
coaxial cables. Connect the F connectors into the F sockets of product and fasten them with an appropriate
force.
•Connect input F sockets marked “A” – “D”, “TERR” with outputs of preceding device in the
cascade LNB/antenna, amplifier, cascadable multiswitch)
•Connect output F sockets marked “A” – “D”, “TERR” with inputs of following device in the cascade
cascadable multiswitch, amplifier) or with 75 Ohm terminators DC-blocked)
•Connect output F sockets marked “1”, “2”, “3”… with wall sockets or receivers or terminate them
with 75 ohm terminators*
•Connect connector marked with protective earth symbol with protective bonding conductor
•Connect DC2.1 socket marked “DC 12V” with power supply
* Termination is not required if terrestrial reception is not used.
2 of 4
6) Product Settings
The product has no adjustable options.
Each connected satellite receiver must be properly set up to have access to all connected LNBs. Follow
instruction manual for satellite receiver or TV set. The most common styles of setup are shown in the table:
SAT SYSTEM LNB) Setting style 1 Setting style 2 Setting style 3
A DiSEqC 1.0: 1 of 4 DiSEqC 1.0: A committed: AA
B DiSEqC 1.0: 2 of 4 DiSEqC 1.0: B committed: AB
C DiSEqC 1.0: 3 of 4 DiSEqC 1.0: C committed: BA
D DiSEqC 1.0: 4 of 4 DiSEqC 1.0: D committed: BB
7) Safety
Due to security reasons the product and wiring in which the product is connected, must be grounded
properly. Use the terminal identified with the appropriate symbol to ground the product. Make sure the
antennas are properly protected against lightning.
The product should be disconnected from the wiring immediately if it gets into contact with liquids dropping
water, spilled drinks etc.).
8) Product Maintenance
The maintenance operation is especially cleansing of the product. Use only dry cloth to clean the product
and do not use any liquid agents.
Coaxial cables installed outdoors should be replaced once in a few years. Unscrew all F connectors and
clean connector contacts, resp. shorten the coaxial cable by approx. 2 cm, every 2 years.
9) Symbols Explanation
Certificate of conformity Protective earth
According to EU directive, electric and electronic devices which are identified by one of the
following symbols must not be disposed of together with municipal waste. When disposing
of the old device, use local waste collection and separation systems.
3 of 4
10) Wiring Examples
TERR ANTENNA
4x LNB
(QUATTRO)
MS17/17+10E P-4
MS17/17+10E P-4
17x cable
MS17/10E P-4
17x cable
PA12
MS17/17+10E P-4
17x cable
A17/17EU -4
TERR ANTENNA
4x LNB
(QUATTRO)
17x Fm-Fm quick
MS17/17+6E P-4
MS17/17+6E P-4
17x cable
MS17/17+6E P-4
17x cable
MS17/17+6E P-4
17x cable
MS17/17+6E P-4
17x cable
MS17/17+6E P-4
17x cable
17x D blocked
load 75Ω
PA12
MS17/17+16E P-12
MS17/17+16E P-12
MS17/17+16E P-12
TERR ANTENNA
4x LNB
(QUATTRO)
17x cable
17x cable
17x D blocked load 75Ω
PA12
More wiring examples are shown at the manufacturer’s website.
4 of 4
11) ontact
Manufacturer: EMP-Centauri s.r.o.
5. kvetna 690
339 01 Klatovy 4
Czech Republic
tel: +420) 376 323 813 sales)
tel: +420) 376 323 853 tech. support)
[email protected]
www.emp-centauri.cz

This manual suits for next models

5

Other EMP-Centauri Switch manuals

EMP-Centauri MS5/12ELP-4 User manual

EMP-Centauri

EMP-Centauri MS5/12ELP-4 User manual

EMP-Centauri P.169-TW User manual

EMP-Centauri

EMP-Centauri P.169-TW User manual

EMP-Centauri S?16/1?PCP-W3 User manual

EMP-Centauri

EMP-Centauri S?16/1?PCP-W3 User manual

EMP-Centauri MS9/4PIU-5 User manual

EMP-Centauri

EMP-Centauri MS9/4PIU-5 User manual

EMP-Centauri MS5/5+2PIP-4 User manual

EMP-Centauri

EMP-Centauri MS5/5+2PIP-4 User manual

EMP-Centauri P.162-IW User manual

EMP-Centauri

EMP-Centauri P.162-IW User manual

EMP-Centauri OMS5/10 User manual

EMP-Centauri

EMP-Centauri OMS5/10 User manual

EMP-Centauri MS13/13+6ECP-4 User manual

EMP-Centauri

EMP-Centauri MS13/13+6ECP-4 User manual

EMP-Centauri OMS5/4 User manual

EMP-Centauri

EMP-Centauri OMS5/4 User manual

EMP-Centauri MS5/32EEU-14 User manual

EMP-Centauri

EMP-Centauri MS5/32EEU-14 User manual

EMP-Centauri T1/1+1ENP8dB-1 User manual

EMP-Centauri

EMP-Centauri T1/1+1ENP8dB-1 User manual

EMP-Centauri P.144-A-5 User manual

EMP-Centauri

EMP-Centauri P.144-A-5 User manual

EMP-Centauri MS9/4EIP-8 User manual

EMP-Centauri

EMP-Centauri MS9/4EIP-8 User manual

EMP-Centauri MS9/6ECP-4 User manual

EMP-Centauri

EMP-Centauri MS9/6ECP-4 User manual

EMP-Centauri P.162-IW User manual

EMP-Centauri

EMP-Centauri P.162-IW User manual

EMP-Centauri MS5/5+12ECP5dB-4 User manual

EMP-Centauri

EMP-Centauri MS5/5+12ECP5dB-4 User manual

EMP-Centauri S16/4PCN-W3 User manual

EMP-Centauri

EMP-Centauri S16/4PCN-W3 User manual

EMP-Centauri MS13/13+32EEU-14 User manual

EMP-Centauri

EMP-Centauri MS13/13+32EEU-14 User manual

EMP-Centauri MS5/6NEU-4 User manual

EMP-Centauri

EMP-Centauri MS5/6NEU-4 User manual

EMP-Centauri S4/1PCT-W2 User manual

EMP-Centauri

EMP-Centauri S4/1PCT-W2 User manual

EMP-Centauri MS5/16NEU-12 User manual

EMP-Centauri

EMP-Centauri MS5/16NEU-12 User manual

EMP-Centauri MS9/9+6ECU-4 User manual

EMP-Centauri

EMP-Centauri MS9/9+6ECU-4 User manual

EMP-Centauri MS17/17+6ECU-4 User manual

EMP-Centauri

EMP-Centauri MS17/17+6ECU-4 User manual

EMP-Centauri S2/1PCN-W1 User manual

EMP-Centauri

EMP-Centauri S2/1PCN-W1 User manual

Popular Switch manuals by other brands

Force 10 E600i TeraScale installation guide

Force 10

Force 10 E600i TeraScale installation guide

Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module... Installation note

Cisco

Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module... Installation note

Allen-Bradley 440P Installation and operating instructions

Allen-Bradley

Allen-Bradley 440P Installation and operating instructions

Eaton LCS Instructional Leaflet

Eaton

Eaton LCS Instructional Leaflet

Nokia 6360 Hardware user's guide

Nokia

Nokia 6360 Hardware user's guide

Cables to Go Port Authority2 user manual

Cables to Go

Cables to Go Port Authority2 user manual

OTS ET2212PpH-S-DR Quick installation guide

OTS

OTS ET2212PpH-S-DR Quick installation guide

Lenovo Flex System Fabric EN4093R user guide

Lenovo

Lenovo Flex System Fabric EN4093R user guide

H3C S5120-SI Series Configuration guide

H3C

H3C S5120-SI Series Configuration guide

Bdcom S2952P Hardware installation manual

Bdcom

Bdcom S2952P Hardware installation manual

Avaya Ethernet Routing Switch 8300 Series quick start

Avaya

Avaya Ethernet Routing Switch 8300 Series quick start

Savant WCD-1 Series Quick reference guide

Savant

Savant WCD-1 Series Quick reference guide

D-Link DKVM-222 user manual

D-Link

D-Link DKVM-222 user manual

FS S5860-48SC Hardware installation and maintenance guide

FS

FS S5860-48SC Hardware installation and maintenance guide

Edge-Core AS4610-30T quick start guide

Edge-Core

Edge-Core AS4610-30T quick start guide

ORiNG RGS-7244GP user manual

ORiNG

ORiNG RGS-7244GP user manual

ATEN CS1642a user manual

ATEN

ATEN CS1642a user manual

StarTech.com MSTDP124DP Quick install guide

StarTech.com

StarTech.com MSTDP124DP Quick install guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.